Bacharach 2772-0803 manual Accuracy, Physical, Power Input Requirements, Outputs

Page 8

REMOTE INTELLIGENT SENSOR - AREA MONITOR

PRODUCT SPECIFICATION

ACCURACY

 

ppb Ranges: ± 15 % of reading ± 1 ppb.

 

ppm Ranges: ± 15 % of reading ± 0.01 ppm.

 

2772-0020: ± 20 % of reading ± 0.01 ppm.

 

2772-0035: ± 20 % of reading ± 0.02 ppm.

PHYSICAL

7" Depth x 11.75" Width x 7.875" Height

Dimensions:

 

(178mm D x 298mm W x 200mm H)

Weight:

11.5 lbs. (5.2 Kg.).

 

Enclosure:

IP-55 with sealed glands (NEMA 4).

 

Cable Glands:

3 x for input/output cables. Pre-wired connector for Optional Printer.

POWER INPUT REQUIREMENTS

 

 

External Power Supply: 12VDC

 

Input Current:

Depends upon model and conditions.

 

Low Flow models:

(200cc/min or less) Cat.# 2772-0010/015/020/030/035/040/060/

 

090/095/100/110/150 etc.

 

 

Normal run current (charged battery)

=150–200mA

 

Run current (discharged battery)

=500–700mA

High Flow models:

(700cc/min or less) Cat.#272-0120/160/175 etc.

 

Normal run current, (charged battery)

=250–300mA

 

Run current (discharged battery)

=600–800mA

OUTPUTS

 

 

Solid State ‘Relay’ Output:

 

Standard System:

1 Combined Gas/ Fault Alarm.

 

Optionally:

2 Gas Alarms plus 1 Fault Alarm, or

 

 

Devices rated @ 1A./60 V DC max.

= 5A peak.

 

Surge current (1 second)

 

Turn on/off time

= 50, ms.

 

On state voltage

= 1.5V DC

Logic:

Off state leakage at 60 V DC across the load = 200, A

Device normally ‘closed’, opens on alarm

Analog Output:

(with standard system software).

 

 

 

Standard:

4–20 mA is default on the instrument.

 

 

0–1 V DC can be hardware selected.

 

 

In both cases the minimum

= zero concentration,

 

and the maximum value

= system range maximum.

 

(Other configurations available. Contact Customer Service)

Page vi

Instruction 2772-0803

Image 8
Contents Instruction Remote Intelligent Sensor Area Monitor Declaration of Conformity Contents Contents Verifying That a GAS Alarm WAS Caused by GAS Cleaning the Sampling Input and Optics BlockPreparation Removal of the Mechanical Chassis Replacing the Mechanical ChassisA1.1 Adjusting Light Levels on Phase 1 RIS Units RIS TEST/FAULT Parameter LOG SheetMonitored Concentration Levels High Supplement aContinuous Diagnostics & System Test Mode Battery BackupUser Selectable Alarm SET Points Optional FeaturesPower Input Requirements AccuracyPhysical OutputsInternal BACK-UP Battery DisplayKeyboard EnvironmentalTable #1 RIS Catalog Numbers & Data System Description Basic PrinciplesDoor Open and Cover Removed from Back of Door Remote Intelligent Sensor Area Monitor Remote Intelligent Sensor Area Monitor Battery Connection Mechanical InstallationElectrical Installation UnpackingSystem Power Supply Consideration & Selection SpecificationSample Lines RIS Type1 Volt Conversion System CheckTools & Materials Required Tape Cassette LoadingCheck and Adjust System For detailed instructions on adjustment Interruption of Test Mode Cycle. IfOption PCB Installation Without Terminal USESilkscreen Idents NAL Phase 2 Base Board Terminal Strips Remote Intelligent Sensor Area Monitor Remote Intelligent Sensor Area Monitor Remote Intelligent Sensor Area Monitor Complete Sampling Sequence Twin Track Tape SAMPLING. AtCHANGE-OVER from Density to Time Mode Density & Time Operating ModesMinimum Sample Time Tape Cassette LifeSystem Alarms ConstantFlashing OpticsDiagnostics Test ModeUsing the Keyboard Optional FeaturesPrinter Operation & USE Optional Feature Installing Test CardSwitch # 2 is not used and is left ‘ON SW1 TotalWhite RED Prdy Black Pprs BaudOFF Non-Bacharach Printer Interface Data Busy GroundMaintenance General Verifying That a GAS Alarm WAS Caused by GASAdjusting Light Levels Clearing a Spurious AlarmAdjusting the Door Switch Checking and Adjusting System Flow RateDisabling the ‘DOOR OPEN’ Alarm Cleaning the Sampling Input and Optics Block Measuring Pump CurrentCleaning Optics block Stepping Clamp Vertical Changing a PumpExterior Cleaning KEY Parameter ChecksInput Path Cleaning Troubleshooting GeneralMechanical Tightness Pump CheckLight Faults Door FaultExcessive Tape USE Tape BreakageRecommended Spares System Power SuppliesModel Dependent Parts Service Centers Common PartsOptions and Supplies Pennsylvania200 to HoldRemote Intelligent Sensor Area Monitor Instruction S-A3 S-A4 Instruction