Bacharach 2772-0803 manual Verifying That a GAS Alarm WAS Caused by GAS

Page 5

REMOTE INTELLIGENT SENSOR - AREA MONITOR

CONTENTS (continued)

3.13 OPTIONAL FEATURES

3-4

3.13.1

RELAY ALARM OPTION

3-4

3.13.2

PRINTER INTERFACE OPTION

3-4

3.13.3

TEST CARD

3-4

3.14 PRINTER OPERATION & USE (OPTIONAL FEATURE)

3-5

3.14.1

GENERAL

3-5

3.14.2

PRINTER SPECIFICATION

3-5

3.14.3

PRINTOUT MODES

3-6

3.14.3.1

Printing 'On Line'

3-6

3.14.3.2

Print at Intervals

3-6

3.14.3.3 Print on Command

3-6

3.14.3.4 Printed Date Format

3-7

3.14.3.5 Data Storage up to 7 Days

3-7

3.14.3.6

Preventing Data Loss

3-7

3.14.4

PRINTER CARD DESCRIPTION

3-7

3.14.4.1 Real Time Clock

3-7

3.14.4.2 Data Storage

3-7

3.14.4.3

Data Communication

3-7

3.14.4.4

Selection of Printer Baud Rate

3-7

3.14.5

CONNECTING A PRINTER

3-7

3.14.5.1 GMD Printer Connection

3-7

3.14.5.2

Connecting a Non-GMD Printer

3-8

3.14.5.3 Portable Use of a Non-GMD Printer

3-8

4 MAINTENANCE AND TROUBLESHOOTING

4-1

4.1

MAINTENANCE GENERAL

4-1

4.2

VERIFYING THAT A GAS ALARM WAS CAUSED BY GAS

4-1

4.3

CLEARING A SPURIOUS ALARM

4-1

4.4

ADJUST LIGHT LEVELS

4-1

4.5

CHECKING AND ADJUST SYSTEM FLOW RATE

4-2

4.6

DISABLING THE ‘DOOR OPEN’ ALARM

4-2

4.7

ADJUST THE DOOR SWITCH

4-2

4.8

MEASURING PUMP CURRENT

4-3

4.9

RESETTING THE PRINTER OPTION STORAGE

4-3

4.10

CLEANING THE SAMPLING INPUT AND OPTICS BLOCK

4-3

 

4.10.1

INTRODUCTION

4-3

 

4.10.2

LIGHT LEVEL ADJUSTMENT

4-3

 

4.10.3

WHEN TO CLEAN

4-3

 

4.10.4

HOW TO CLEAN

4-4

 

4.10.5 DIRECT CLEANING OF THE LED’S AND PHOTO DIODES

4-4

 

4.10.6 REPLACING THE OPTICS BLOCK

4-4

4.10.7WHAT TO DO IF CLEANING DOES NOT RECTIFY THE PROBLEM .. 4-5

4.11 CHANGING A PUMP

4-5

4.11.1 PREPARATION

4-6

4.11.2 REMOVAL OF THE MECHANICAL CHASSIS

4-6

4.11.3

PUMP REMOVAL

4-6

4.14.4

FITTING THE NEW PUMP

4-6

4.14.5REPLACING THE MECHANICAL CHASSIS AND

SETTING PUMP FLOW

4-6

Instruction2772-0803

Page iii

Image 5
Contents Instruction Remote Intelligent Sensor Area Monitor Declaration of Conformity Contents Contents Cleaning the Sampling Input and Optics Block Verifying That a GAS Alarm WAS Caused by GASPreparation Removal of the Mechanical Chassis Replacing the Mechanical ChassisRIS TEST/FAULT Parameter LOG Sheet A1.1 Adjusting Light Levels on Phase 1 RIS UnitsMonitored Concentration Levels High Supplement aBattery Backup Continuous Diagnostics & System Test ModeUser Selectable Alarm SET Points Optional FeaturesAccuracy Power Input RequirementsPhysical OutputsDisplay Internal BACK-UP BatteryKeyboard EnvironmentalTable #1 RIS Catalog Numbers & Data Basic Principles System DescriptionDoor Open and Cover Removed from Back of Door Remote Intelligent Sensor Area Monitor Remote Intelligent Sensor Area Monitor Mechanical Installation Battery ConnectionElectrical Installation UnpackingSpecification System Power Supply Consideration & SelectionRIS Type Sample LinesSystem Check 1 Volt ConversionTools & Materials Required Tape Cassette LoadingCheck and Adjust System Interruption of Test Mode Cycle. If For detailed instructions on adjustmentOption PCB Installation Without Terminal USESilkscreen Idents NAL Phase 2 Base Board Terminal Strips Remote Intelligent Sensor Area Monitor Remote Intelligent Sensor Area Monitor Remote Intelligent Sensor Area Monitor Twin Track Tape SAMPLING. At Complete Sampling SequenceDensity & Time Operating Modes CHANGE-OVER from Density to Time ModeMinimum Sample Time Tape Cassette LifeConstant System AlarmsFlashing OpticsTest Mode DiagnosticsUsing the Keyboard Optional FeaturesInstalling Test Card Printer Operation & USE Optional FeatureSW1 Total Switch # 2 is not used and is left ‘ONWhite RED Prdy Black Pprs BaudOFF Data Busy Ground Non-Bacharach Printer InterfaceVerifying That a GAS Alarm WAS Caused by GAS Maintenance GeneralAdjusting Light Levels Clearing a Spurious AlarmAdjusting the Door Switch Checking and Adjusting System Flow RateDisabling the ‘DOOR OPEN’ Alarm Measuring Pump Current Cleaning the Sampling Input and Optics BlockCleaning Optics block Changing a Pump Stepping Clamp VerticalKEY Parameter Checks Exterior CleaningTroubleshooting General Input Path CleaningMechanical Tightness Pump CheckDoor Fault Light FaultsExcessive Tape USE Tape BreakageRecommended Spares System Power SuppliesModel Dependent Parts Common Parts Service CentersOptions and Supplies PennsylvaniaHold 200 toRemote Intelligent Sensor Area Monitor Instruction S-A3 S-A4 Instruction