Property Damage Hazard

AJlwater heaters eventually leak

Do notinstall without adequate drainage.

IMPORTANT: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of water, the tank wilt eventually leak after an extended period of time. Also any external plumbing leak, including those from improper installation, may cause early failure of the tank due to corrosion if not repaired. If the homeowner is uncomfortable with making the repair a qualified technician should be contacted. A suitable metal drain pan should be installed under the water heater as shown below, to help protect the property from damage which may occur from condensate formation or leaks in the piping connections or tank. The pan must limit the water level to a maximum depth of 1-3/4" and be two inches wider than the heater and piped to an adequate drain. NOTE: The pan must not restrict combustion air flow. Locate the water heater near a suitable indoor drain. Outside drains are subject to freezing temperatures which can obstruct the drain line. The piping should be at least 3/4" ID and pitched for proper drainage.

0

METAL

DRAIN

PAN

PIPED TO AN

ADEQUATE DRAIN

ATLEAST2"GREATERTHATH;'.

DIAMETER OF THE WATER HEATER.

FIGURE 9.

Water heater life depends upon water quality, water usage,

water temperature and the environment in which the water heater is installed. Water heaters are sometimes installed

in locations where leakage may result in property damage, even with the use of a drain pan piped to a drain. However, unanticipated damage can be reduced or prevented by a leak detector or water shut-off device used in conjunction with a piped drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:

Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when water is detected.

Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain pan.

Water supply shut-off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater.

Devices that wilt turn off the gas supply to a gas water heater while at the same time shutting off its water supply.

Insulation Blankets

Insulation blankets available to the general public for external

use on gas water heaters are not necessary with Kenmore products. The purpose of an insulation blanket is to reduce the standby heat toss encountered with storage tank heaters. Your Kenmore water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

Breathing Hazard - Carbon Monoxide Gas

intake with insulating blanket.

io not obstruct water heater air Gas and carbon monoxide detectors are available.

Install water heater in accordance with the instruction manual.

I

Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual.

_k, WARNING

Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.

Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood.

Do not cover the outer door, thermostat or temperature & pressure relief valve.

Do not allow insulation to come within 2" (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner.

Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.

Do obtain new warning and instruction labels from Sears

for placement on the blanket directly over the existing labels.

Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air flow.

Clearances and Accessibility

NOTE: Minimum clearances from combustible materials are

stated on the label adjacent to the gas control valve/thermostat of the water heater. The water heater is certified for installation

on a combustible floor.

IMPORTANT: If installing over carpeting, the carpeting must be protected by a metal or wood panel beneath the water heater. The protective panel must extend beyond the full width and depth of the water heater by at least three inches (76.2mm) in any direction; or if in an alcove or closet installation, the entire floor must be covered by the panel.

Figure 10 may be used as a reference guide to locate the specific clearance locations. A minimum of 24 inches of front clearance should be provided for inspection and service.

13

Image 13 Contents
=iI=1,Ctd,,,it= 153.331492 Gallon 153.331592Important Definitions Read and follow water heater warnings and instructionsFire or Explosion Harzard Improper installation and use may result in property damageFire Hazard GAS Supply Troubleshootingguide Year Limited Warranty on Water Heater Important Information About This Water Heater Excessive Weight HazardMaterials Needed Vent Pipe Inner Door Gas Control GET to Know Your Water Heater GAS ModelsInstallation Checklist Manualgas SHUT-OFFVALVE Removing the Old Water HeaterCSite Location Location RequirementsCarbon Monoxide Poisoning Hazard Fire or Explosion HazardInsulation Blankets Clearances and AccessibilityProperty Damage Hazard Breathing Hazard Carbon Monoxide GasGas Requirements Filling the Water HeaterGas Piping Explosion HazardGas Pressure Gas Pressure TestingUnconfined Space Carbon Monoxide WarningAll Air from Inside the Building Confined SpaceLouvers and Grilles All Air from OutdoorsVent Connectors Draft Hood InstallationVent Pipe Size Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionTvALvE Piping InstallationTemperature & Pressure Relief Valve Temperature and Pressure Relief ValveClosed System/Thermal Expansion Explosion HarzardWhat to do if YOU Smell GAS Lighting InstructionsChecking the Draft Water Temperature RegulationBurner Flames Emergency Shut DownGascontroutemperatureknob Vent System Inspection Tank Sediment CleaningBurner Inspection Caon Monoxide and Fire HazardHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection Draining and FlushingService Full Assembly Electronic Control Module External Inspection & Cleaning Base-Ring Filter Replacement PartsRemoving the Burner from the Manifold Burner Assembly Removing the Manifold/Burner AssemblyExplosion Hazard Cleaning the Combustion Chamber and Flame-arrestorPiezoelectric Igniter System Expansion Tank Sizing Chart Expansion Tank SpecificationsStart Up Conditions Strange SoundsOperational Conditions Page Problemled Status Problem Page Page Page Page Page