SERVICE AND ADJUSTMENT

Tank (Sediment) Cleaning

Sediment build-up on the tank bottom may create varying amount of noise, and if left in the tank will cause permanent tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. In these cases, Mag-Erad (part no. 23600) can be used to help remove the sediment deposits. This may be ordered from the Sears Service Center. For ordering, refer to the “Parts Order List” section.

Vent System Inspection

Burner Inspection

Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a flooded water heater will create dangerous conditions which can cause

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Contact a Sears Service Center to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

At least once a year, a visual inspection should be made of the main burner and pilot burner. See Figure 29.

You should check for sooting. Soot is not normal and will impair proper combustion.

Soot build-up indicates a problem that requires correction before further use. Turn “OFF” gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fire causing death, serious injury, or property damage.

FIGURE 29.

Burner Cleaning

At least once a year, a visual inspection should be made of the venting system. You should look for:

Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed.

Damage or deterioration which could cause improper venting or leakage of combustion products.

Rusted flakes around top of water heater.

Be sure the vent piping is properly connected to prevent escape of dangerous flue gasses which could cause deadly asphyxiation.

Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

If when inspecting the vent system you find sooting or deterioration, something is wrong. Call the local gas supplier to correct the problem and clean or replace the flue and venting before resuming operation of the water heater.

In the event your burner needs cleaning, follow these instructions:

If inspection of the burner shows that cleaning is required, turn the gas control knob clockwise ( ) to the “OFF” position, depressing slightly.

NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly. DO NOT FORCE.

The burner needs to be removed for cleaning. Call the Sears Service Center to remove and clean the burner and correct the problem that required the burner to be cleaned.

25

Image 25
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Power Miser GAS Water HeaterSafety Precautions Safe INSTALLATION, USE and ServiceFire or Explosion Harzard Table of Contents Troubleshooting Guide Year Limited Warranty on Water Heater Product WarrantyCustomer Responsibilities Product SpecificationsMaterials Needed Materials and Basic Tools NeededGET to Know Your Water Heater GAS Models Typical InstallationImportant Information about this Water Heater Installation ChecklistRemoving the Old Water Heater Installation InstructionsSite Location Location RequirementsInsulation Blankets Clearances and AccessibilityGAS Supply Filling the Water HeaterGas Requirements Gas PipingGas Pressure Gas Pressure TestingLP Gas Only Unconfined Space Combustion AIR Supply & VentilationAll Air from Inside the Building Louvers and Grilles All Air from OutdoorsVent Connectors Draft Hood InstallationVent Pipe System Vent Pipe SizeVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveLighting Instructions Operating Your Water HeaterBurner Flames Checking the Draft Water Temperature RegulationEmergency Shut Down White Rodgers GAS Valve GAS Control Knob OFF-PILOT-ON Tank Sediment Cleaning Service and AdjustmentBurner Cleaning Vent System Inspection Burner InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection Draining and FlushingService Maintenance of Your Water Heater Cleaning the Combustion Chamber and Flame-arrestor Replacing the Pilot/ Pilot Tube AssemblyPiezoelectric Igniter System Replacing the Manifold/Burner AssemblyFvir System Operational Checklist Testing the Igniter SystemRemoving and Replacing the Gas Control Valve/Thermostat Start Up Conditions Troubleshooting GuideCondensation Operational ConditionsLeakage Checkpoints Problem Possible Causes Corrective Action Troubleshooting ChartThermostat Fails to YES Pilot Light Troubleshooting FlowchartModel Numbers Parts Order ListPage MY-HOME1-800-469-4663 Get it fixed, at your home or ours