WHITE RODGERS GAS VALVE GAS CONTROL KNOB

(OFF-PILOT-ON)

Temperature

Time to Produce 2nd & 3rd

Settings

Degree Burns on Adult Skin

INDEX BAR

TEMPERATURE DIAL

160°F

150°F

140°F

130°F 120°F

VERY HOT= approx. 160°F (71°C)

About 1/2 second

C = approx. 150°F (66°C)

About 1-1/2 seconds

B = approx. 140°F (60°C)

Less than 5 seconds

A = approx. 130°F (54°C)

About 30 seconds

= approx. 120°F (49°C)

More than 5 minutes

LOW = approx. 80°F (27°C)

- - - - - - - - - - - - - - - -

FIGURE 28.

NOTE: During low demand periods when hot water is not being used, a lower thermostat setting will reduce energy losses and may satisfy your normal hot water needs. If hot water use is expected to be more than normal, a higher thermostat setting may be required to meet the increased

demand. When leaving your home for extended periods (vacations, etc.) turn the temperature dial to its lowest setting. This will maintain the water at low temperatures with minimum energy losses and prevent the tank from freezing during cold weather.

24

Image 24
Contents Power Miser GAS Water Heater Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.ASafe INSTALLATION, USE and Service Safety PrecautionsFire or Explosion Harzard Table of Contents Troubleshooting Guide Product Warranty Year Limited Warranty on Water HeaterProduct Specifications Customer ResponsibilitiesMaterials and Basic Tools Needed Materials NeededTypical Installation GET to Know Your Water Heater GAS ModelsInstallation Checklist Important Information about this Water HeaterInstallation Instructions Removing the Old Water HeaterLocation Requirements Site LocationClearances and Accessibility Insulation BlanketsFilling the Water Heater GAS SupplyGas Requirements Gas PipingGas Pressure Testing Gas PressureLP Gas Only Combustion AIR Supply & Ventilation Unconfined SpaceAll Air from Inside the Building All Air from Outdoors Louvers and GrillesDraft Hood Installation Vent ConnectorsVent Pipe System Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionOperating Your Water Heater Lighting InstructionsChecking the Draft Water Temperature Regulation Burner FlamesEmergency Shut Down White Rodgers GAS Valve GAS Control Knob OFF-PILOT-ON Service and Adjustment Tank Sediment CleaningBurner Cleaning Vent System Inspection Burner InspectionTemperature-Pressure Relief Valve Operation HousekeepingAnode Rod Inspection Draining and FlushingService Maintenance of Your Water Heater Replacing the Pilot/ Pilot Tube Assembly Cleaning the Combustion Chamber and Flame-arrestorReplacing the Manifold/Burner Assembly Piezoelectric Igniter SystemTesting the Igniter System Fvir System Operational ChecklistRemoving and Replacing the Gas Control Valve/Thermostat Troubleshooting Guide Start Up ConditionsOperational Conditions CondensationLeakage Checkpoints Troubleshooting Chart Problem Possible Causes Corrective ActionThermostat Fails to Pilot Light Troubleshooting Flowchart YESParts Order List Model NumbersPage Get it fixed, at your home or ours MY-HOME1-800-469-4663