Kenmore 153.331572 owner manual Service

Page 27

down during freezing temperatures. To drain the tank, perform the following steps:

1.Turn off the gas to the water heater at the manual gas shut- off valve.

2.Close the cold water inlet valve.

3.Open a nearby hot water faucet.

4.Connect a hose to the drain valve and terminate it to an adequate drain.

NOTE: The drain hose should be rated for at least 200°F. If the drain hose does not have this rating, open the cold water inlet valve and a nearby hot faucet until the water is no longer hot.

5.Open the water heater drain valve and allow all the water to drain from the tank. Flush the tank with water as needed to remove sediment.

6.Close the drain valve, refill the tank, and restart the heater as directed under the “Operating Your Water Heater” section.

If the water heater is going to be shut down for an extended

period, the drain valve should be left open.

IMPORTANT: Condensation may occur when refilling the tank and should not be confused with a tank leak.

Service

Before calling for repair service, please read the Troubleshooting Guide in this manual.

If a condition persists or you are uncertain about the operation of the water heater, let the Sears Service Center check it out.

Contact Sears Service Center at:

1-800-4-MY-HOME® (1-800-469-4663).

27

Image 27
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Power Miser GAS Water HeaterSafety Precautions Safe INSTALLATION, USE and ServiceFire or Explosion Harzard Table of Contents Troubleshooting Guide Year Limited Warranty on Water Heater Product WarrantyCustomer Responsibilities Product SpecificationsMaterials Needed Materials and Basic Tools NeededGET to Know Your Water Heater GAS Models Typical InstallationImportant Information about this Water Heater Installation ChecklistRemoving the Old Water Heater Installation InstructionsSite Location Location RequirementsInsulation Blankets Clearances and AccessibilityGas Piping Filling the Water HeaterGAS Supply Gas RequirementsGas Pressure Testing Gas PressureLP Gas Only Combustion AIR Supply & Ventilation Unconfined SpaceAll Air from Inside the Building Louvers and Grilles All Air from OutdoorsVent Pipe Size Draft Hood InstallationVent Connectors Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveLighting Instructions Operating Your Water HeaterChecking the Draft Water Temperature Regulation Burner FlamesEmergency Shut Down White Rodgers GAS Valve GAS Control Knob OFF-PILOT-ON Vent System Inspection Burner Inspection Service and AdjustmentTank Sediment Cleaning Burner CleaningDraining and Flushing Temperature-Pressure Relief Valve OperationHousekeeping Anode Rod InspectionService Maintenance of Your Water Heater Cleaning the Combustion Chamber and Flame-arrestor Replacing the Pilot/ Pilot Tube AssemblyPiezoelectric Igniter System Replacing the Manifold/Burner AssemblyTesting the Igniter System Fvir System Operational ChecklistRemoving and Replacing the Gas Control Valve/Thermostat Start Up Conditions Troubleshooting GuideCondensation Operational ConditionsLeakage Checkpoints Problem Possible Causes Corrective Action Troubleshooting ChartThermostat Fails to YES Pilot Light Troubleshooting FlowchartModel Numbers Parts Order ListPage MY-HOME1-800-469-4663 Get it fixed, at your home or ours