TROUBLESHOOTING CHART
PROBLEM |
| POSSIBLE CAUSE(S) |
| CORRECTIVE ACTION |
BURNER WILL NOT IGNITE | 1. | Pilot not lit | 1. | Light pilot |
| 2. | Thermostat set too low | 2. | Turn temp. dial to desired temperature |
| 3. | No gas | 3. | Check with gas utility company |
| 4. | Dirt in the gas lines | 4. | Notify |
| 5. | Pilot line clogged | 5. | Clean, locate source and correct |
| 6. | Main burner line clogged | 6. | Clean, locate source and correct |
| 7. | 7. | Replace thermocouple | |
| 8. | 8. | Replace thermostat | |
| 9. | Heater installed in a confined area | 9. | Provide fresh air ventilation |
SMELLY WATER | 1. | Sulfides in the water | 1. | Replace the anode with a special anode |
BURNER FLAME YELLOW- | 1. | Insufficient secondary air | 1. | Provide ventilation to water heater |
LAZY | 2. | Low gas pressure | 2. | Check with gas utility company |
| 3. | Water heater flue or vent system | 3. | Clean, locate source and correct |
| 4. | blocked | ||
| Main burner line clogged | 4. | Clean, locate source and correct | |
| 5. | Heater installed in a confined area | 5. | Proper fresh air ventilation |
| 6. | Obstruction in main burner orifice | 6. | Clean or replace orifice |
PILOT WILL NOT LIGHT OR | 1. | 1. | Replace igniter pilot assembly | |
REMAIN LIT | 2. | The thermal switch tripped | 2. | See Pilot Light Troubleshooting Flowchart section |
| 3. | Wire lead connection at thermal switch | 3. | Remove and reconnect the wire leads at |
|
| loose |
| thermal switch, confirm connections are tight |
| 4. | Thermocouple connection loose | 4. | and not loose |
| Finger tighten; then 1/4 turn with wrench | |||
| 5. | Air in gas line | 5. | Bleed the air from the gas line |
| 6. | Low gas pressure | 6. | Check with gas utility company |
| 7. | No gas | 7. | Check with gas utility company |
| 8. | Dirt in gas lines | 8. | Notify |
| 9. | Cold drafts | 9. | Locate source and correct |
| 10. | Thermostat ECO switch open | 10. | Replace thermostat |
| 11. | Pilot line or orifice clogged | 11. | Clean, locate source and correct |
| 12. | 12. | Replace thermocouple | |
| 13. | Air for combustion obstructed | 13. | See maintenance section for inspection and |
| 14. | Flammable vapors incident, FVIR | 14. | cleaning of flame arrester |
| Replace water heater, eliminate flammable | |||
| 15. | function actuated | 15. | vapors source. Contact Sears Service. |
| Inspect and clean | |||
|
|
|
| Cleaning & Inspection of the |
HIGH OPERATION COSTS | 1. | Thermostat set too high | 1. | Set temperature dial to lower setting |
| 2. | Sediment or lime in tank | 2. | |
| 3. | Water heater too small for job | 3. | Install adequate heater |
| 4. | Wrong piping connections | 4. | Correct |
| 5. | Leaking faucets | 5. | Repair faucets |
| 6. | Gas leaks | 6. | Check with |
| 7. | Wasted hot water | 7. | Advise customer |
| 8. | Long runs of exposed piping | 8. | Insulate piping |
| 9. | Hot water piping in exposed wall | 9. | Insulate piping |
INSUFFICIENT HOT WATER | 1. | Thermostat set too low | 1. | Turn temperature dial to desired setting |
| 2. | Sediment or lime in tank | 2. | |
| 3. | Water heater too small | 3. | Install adequate heater |
| 4. | Wrong piping connections | 4. | Correct |
| 5. | Leaking faucets | 5 | Repair faucets |
| 6. | Wasted hot water | 6. | Advise customer |
| 7. | Long runs of exposed piping | 7. | Insulate piping |
| 8. | Hot water piping in outside wall | 8. | Insulate piping |
| 9. | Low gas pressure | 9. | Check with gas utility company |
SLOW HOT WATER | 1. | Insufficient secondary air | 1. | Provide ventilation to water heater. Check flue |
RECOVERY | 2. | Water heater flue or vent system | 2. | way, flue baffle, and burner |
| Clean flue, locate source and correct | |||
| 3. | blocked | 3. | Check with gas utility company |
| Low gas pressure | |||
| 4. | Improper calibration | 4. | Replace thermostat |
| 5. | Thermostat set too low | 5. | Turn temperature dial to desired setting |
| 6. | Water heater too small | 6. | Install adequate heater |
| 7. | Wrong piping connections | 7. | Correct |
| 8. | Wasted hot water | 8. | Advise customer |
DRIP FROM RELIEF VALVE | 1. | Excessive water pressure | 1. | Use a pressure reducing valve and relief |
| 2. | Heater stacking | 2. | valve |
| 3. | Closed water system | Lower the thermostat setting | |
|
|
| 3. | See “Closed System/Thermal Expansion” |
35