Kenmore 153.331572 owner manual Troubleshooting Guide, Start Up Conditions

Page 32

TROUBLESHOOTING GUIDE

Start Up Conditions

Thermal Expansion

NOTE: Expansion tanks are pre-charged with a 40 psi air charge. If the inlet water pressure is higher than 40 psi, the expansion tank’s air pressure must be adjusted to match that pressure, but must not be higher than 80 psi.

As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent temperature-pressure relief valve operation: water discharged from the valve due to excessive pressure build up. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This condition is not covered under the limited warranty.

A properly sized thermal expansion tank should be installed on all closed systems to control the harmful effects of thermal expansion. Thermal expansion tanks are available from Sears stores and through the Sears Service Centers. Contact the local plumbing inspector, water supplier and/or the Sears Service Center for assistance in controlling these situations. See Figure 42.

TABLE 5

Thermal Expansion Tank Specifications

 

Tank

Dimensions

Pipe

Model

Capacity

in Inches

 

Fitting

Number

In Gallons

Diameter

 

Length

On Tank

153.331020

2

8 (203 mm)

12-3/4 (323 mm)

3/4” Male

153.331050

5

11 (279 mm)

14-3/4 (375 mm)

3/4” Male

 

 

 

 

 

 

TABLE 6

Expansion Tank Sizing Chart

 

Inlet*

 

Water Heater Capacity (Gallons)

 

Water

 

 

 

 

 

 

Expansion

Pressure

 

30

40

50

66

82

40psi

2

2

2

5

5

Tank

50psi

2

2

2

5

5

Capacity

60psi

2

2

5

5

5

Needed

70psi

2

2

5

5

5

 

80psi

2

5

5

5

5

 

 

 

 

 

 

 

 

*Highest recorded inlet water pressure in a 24 hour period or regulated water pressure.

FIGURE 42.

Strange Sounds

Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not represent harmful or dangerous conditions.

Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal. See “Condensation” section.

Draft Hood Operation

Check draft hood operation by performing a worst case depressurization of the building. With all doors and windows closed, and with all air handling equipment and exhaust fans operating such as furnaces, clothes dryers, range hoods and bathroom fans, a match flame should still be drawn into the draft hood of the water heater with its burner firing. If the flame is not

32

Image 32
Contents Power Miser GAS Water Heater Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.ASafe INSTALLATION, USE and Service Safety PrecautionsFire or Explosion Harzard Table of Contents Troubleshooting Guide Product Warranty Year Limited Warranty on Water HeaterProduct Specifications Customer ResponsibilitiesMaterials and Basic Tools Needed Materials NeededTypical Installation GET to Know Your Water Heater GAS ModelsInstallation Checklist Important Information about this Water HeaterInstallation Instructions Removing the Old Water HeaterLocation Requirements Site LocationClearances and Accessibility Insulation BlanketsFilling the Water Heater GAS SupplyGas Requirements Gas PipingLP Gas Only Gas Pressure TestingGas Pressure All Air from Inside the Building Combustion AIR Supply & VentilationUnconfined Space All Air from Outdoors Louvers and GrillesDraft Hood Installation Vent ConnectorsVent Pipe System Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionOperating Your Water Heater Lighting InstructionsEmergency Shut Down Checking the Draft Water Temperature RegulationBurner Flames White Rodgers GAS Valve GAS Control Knob OFF-PILOT-ON Service and Adjustment Tank Sediment CleaningBurner Cleaning Vent System Inspection Burner InspectionTemperature-Pressure Relief Valve Operation HousekeepingAnode Rod Inspection Draining and FlushingService Maintenance of Your Water Heater Replacing the Pilot/ Pilot Tube Assembly Cleaning the Combustion Chamber and Flame-arrestorReplacing the Manifold/Burner Assembly Piezoelectric Igniter SystemRemoving and Replacing the Gas Control Valve/Thermostat Testing the Igniter SystemFvir System Operational Checklist Troubleshooting Guide Start Up ConditionsOperational Conditions CondensationLeakage Checkpoints Troubleshooting Chart Problem Possible Causes Corrective ActionThermostat Fails to Pilot Light Troubleshooting Flowchart YESParts Order List Model NumbersPage Get it fixed, at your home or ours MY-HOME1-800-469-4663