ARMING PERIMETER ONLY (With Entry Delay OFF)

 

Using the

Use this key when staying inside and do not expect anyone to use an entry/exit door.

Ê 7 Ê

INSTANT Key

CAUTION: Arming the system in this mode will greatly increase the chance of

 

 

false alarms. Use extreme care in selecting this mode of arming.

 

 

BEFORE ARMING, close all doors and windows (see CHECKING FOR OPEN ZONES on page 13)

THE INSTANT MODE ARMS THE PERIMETER (INCLUDING ENTRY/EXIT DOOR), WITH NO ENTRY DELAY. PERSONS WITHIN THE PREMISES CAN MOVE ABOUT FREELY

Ask your installer if this feature is programmed in your system. If so, place a check in this box. ÊÊÊÊ

1.Enter your security code and press the INSTANT [7] key.

2.The touchpad beeps three times and displays the armed message. The red ARMED indicator lights. Note that there is an exit delay in effect before arming actually takes place. See the note below.

3.After arming, an alarm sounds immediately if any protected perimeter door or window is opened, but you may otherwise move freely throughout the premises.

An alarm sounds immediately if anyone opens an entry/exit door.

Exit Delay Restart. If you wish to open the entry/exit door to let someone in after Êarming INSTANT, you can re-start the exit delay at any time Ð simply press the [] Êkey, then let that person in. This avoids having to disarm the system and then re-arm it Êagain.

Note: When you first arm the system in the INSTANT mode, ÒYou may exit nowÓ will be displayed on the second line of a Custom Display touchpad during the programmed exit delay. This delay is in effect in the system even when arming INSTANT. When the exit delay period ends, ÒYou may exit now Ó disappears and the system is fully armed in the INSTANT mode.

TYPICAL DISPLAYS Ð ÊÒARMED INSTANTÓ

 

 

 

 

 

 

 

 

 

 

AC

 

 

 

ARME D *INSTANT*

 

 

STAY

 

 

 

 

 

 

INSTANT

 

 

 

 

YOU M AY E XIT NOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH DISPLAY TOUCHPAD

CUSTOM DISPLAY TOUCHPAD

Ð 15 Ð

Image 15
Contents Security System About This Manual Table of Contents General Partitioned System System OverviewSystem Overview Single-Button Paging ENTRY/EXIT Delays General InformationPartition ENTRY/EXIT Delays Exit AlarmsCommon Zone Operation About the Touchpads 10 Ð About the Touchpads11 Ð Functions of the TouchpadsEnglish Display Touchpad Custom English Display Touchpad12 Ð Using the Ready Key Checking for Open Zones13 Ð Arming Perimeter only With Entry Delay on Using 3 Ê Stay Key14 Ð Arming Perimeter only With Entry Delay OFF Instant Key15 Ð 16 Ð Arming ALL Protection With Entry Delay onUsing 2 Ê Êaway Key Use this key when no one will be staying insideDisarming and Silencing Alarms Using 1 Ê Êoff Key17 Ð Using 6 Ê Bypass Key Bypassing Protection Zones18 Ð 19 Ð Bypassing Protection ZonesTo turn Chime Mode off Chime ModeUsing 9 Ê Êchime Key To turn Chime Mode on21 Ð For Manually Activating Silent AND/OR Audible AlarmsUsing Panic Keys Panic KeysManually Initiating a Fire Alarm Verify this with your installer22 Ð Using Device Commands Enter Security Code then Press # + 7 + Device NumberEnter Security Code then Press # + 8 + Device Number 24 Ð Paging FeatureSecurity Codes Duress Code Quick Arming Single-Button25 Ð Security Codes 27 Ð Testing the SystemUsing the Test Key ÊEnter the security code, then press Test key28 Ð Exit Test ModeCheck and Battery Displays Trouble Conditions29 Ð Modem Comm Trouble ConditionsCOMM. Failure System LO BATLong Rng Trbl Total Power Failure Busy-StandbyDisabled. Call for Service Immediately Open CircuitMaintaining Your System 33 Ð Maintaining Your System34 Ð Quick Guide to System Functions35 Ð Summary of AUDIBLE/VISUAL Notifications36 Ð Summary of AUDIBLE/VISIBLE Notifications37 Ð UL Notice This is a Grade a Residential System38 Ð Federal Communications Commission FCC Part 68 Statement39 Ð Avis40 Ð Limitations of this Alarm System41 Ð Limitations of this Alarm System42 Ð Limited Warranty43 Ð InstallationÀN7527-6V2Dä