ADT Security Services Security System Bypassing Protection Zones, Using 6 Ê Bypass Key, 18 Ð

Page 18

BYPASSING PROTECTION ZONES

Using the

ÊÊ 6 Ê BYPASS Key

All bypasses are removed when an OFF sequence (security code plus OFF) is performed.

TO BYPASS ZONES:

¥ Enter code.

This key is used when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first.

1.Enter your security code and press the BYPASS [6] key.

2.Enter the zone number(s) for the zone(s) to be bypassed (e.g., 06, 10, 13, etc.).

Single digit zone numbers must be preceded by a zero (e.g. 05, 06).

3.When finished, the touchpad will momentarily display a "Bypass" message for each bypassed zone number. Wait for these zones to be displayed, to confirm their bypass.

4.Arm the system as usual.

Bypassed zones are unprotected and will not cause an alarm if violated while your system is armed.

TYPICAL MOMENTARY DISPLAYS

TYPICAL DISPLAYS AFTER ALL BYPASSED

OF BYPASSED ZONE(S)

ZONES HAVE BEEN DISPLAYED (PRIOR TO ARMING)

¥ Press BYPASS key.

¥ Enter zone Nos.

¥ Wait for bypassed zones

ÊÊto be displayed.

¥ Arm system as usual.

BYPASS 06

BE DROOM WINDOW

CUSTOM DISPLAY TOUCHPAD

DISARMED BYPASS RE ADY TO ARM

CUSTOM DISPLAY TOUCHPAD

Ê06

AC

BYPASS

THE ÒREADYÓ INDICATOR WILL LIGHT TO SIGNIFY THAT THE SYSTEM IS READY TO ARM

AC

BYPASS

ENGLISH DISPLAY TOUCHPAD

ENGLISH DISPLAY TOUCHPAD

To display bypassed zones prior to arming (see displays above, right), enter your security code and press the BYPASS [6] key. This will also bypass any open zones at that time (if ÒQuick BypassÓ is enabled Ð see following page).

Ð 18 Ð

Image 18
Contents Security System About This Manual Table of Contents System Overview General Partitioned SystemSystem Overview Single-Button Paging ENTRY/EXIT Delays General InformationPartition ENTRY/EXIT Delays Exit AlarmsCommon Zone Operation About the Touchpads About the Touchpads 10 ÐFunctions of the Touchpads 11 ÐEnglish Display Touchpad Custom English Display Touchpad12 Ð Using the Ready Key Checking for Open Zones13 Ð Arming Perimeter only With Entry Delay on Using 3 Ê Stay Key14 Ð Arming Perimeter only With Entry Delay OFF Instant Key15 Ð Use this key when no one will be staying inside Arming ALL Protection With Entry Delay onUsing 2 Ê Êaway Key 16 ÐDisarming and Silencing Alarms Using 1 Ê Êoff Key17 Ð Using 6 Ê Bypass Key Bypassing Protection Zones18 Ð Bypassing Protection Zones 19 ÐTo turn Chime Mode on Chime ModeUsing 9 Ê Êchime Key To turn Chime Mode offPanic Keys For Manually Activating Silent AND/OR Audible AlarmsUsing Panic Keys 21 ÐManually Initiating a Fire Alarm Verify this with your installer22 Ð Using Device Commands Enter Security Code then Press # + 7 + Device NumberEnter Security Code then Press # + 8 + Device Number Paging Feature 24 ÐSecurity Codes Duress Code Quick Arming Single-Button25 Ð Security Codes ÊEnter the security code, then press Test key Testing the SystemUsing the Test Key 27 ÐExit Test Mode 28 ÐCheck and Battery Displays Trouble Conditions29 Ð System LO BAT Trouble ConditionsCOMM. Failure Modem CommOpen Circuit Total Power Failure Busy-StandbyDisabled. Call for Service Immediately Long Rng TrblMaintaining Your System Maintaining Your System 33 ÐQuick Guide to System Functions 34 ÐSummary of AUDIBLE/VISUAL Notifications 35 ÐSummary of AUDIBLE/VISIBLE Notifications 36 ÐUL Notice This is a Grade a Residential System 37 ÐFederal Communications Commission FCC Part 68 Statement 38 ÐAvis 39 ÐLimitations of this Alarm System 40 ÐLimitations of this Alarm System 41 ÐLimited Warranty 42 ÐInstallation 43 ÐÀN7527-6V2Dä