Therma-Stor Products Group Ultra-Aire 100V Ventilation Timer and Humidity Control Panel

Page 7
Figure 4
Fan/Filter Switch
Figure 3
Humidity Control Adjustment Knob

FOR HVAC INSTALLER ONLY

4.2Ventilation Timer and Humidity Control Panel

See Figure 2: The ventilation timer and humidity control panel automatically controls both the ventilation and the humidity of the living space. The ventilation timer and humidity control panel contains an adjustable humidity control, a fan switch, and a ventilation timer. This panel will control the humidity and allow

 

 

Figure 1:

Figure 2: Ventilation Timer

Humidity/Fan Control Panel

and Humidity Control Panel

Part No. 4024155

Part No. 4024125

 

 

programmed ventilation of the living space. This panel works in conjunction with the optional fresh air damper to provide ventilation.

This panel should be mounted in a central area of the structure where it can accurately sense the humidity of the air in the living space. The panel has small slots that must remain open to the air within the living space for accurate humidity sensing.

4.3 Humidity Control Adjustment

Set the humidity control to the desired humidity level for the home. The dehumidifier will run continuously until the relative humidity (RH) is reduced to the humidity control dial setting. Setting the humidity control to lower RH levels will NOT increase the unit's dehumidification rate; the unit will simply run longer to reduce the area's RH to the setting. The Ultra-Aire unit (and refrigerant

based dehumidifiers in general) will reduce a warm space's RH to a lower level than that of a cool space. It is therefore pointless to set the humidity control to excessively low levels in cool rooms; doing so will result in long periods of ineffective dehumidifier run time.

Quality humidity meters are available from the factory and are recommended to accurately monitor humidity levels.

4.4 Fan/Filter Switch

Turning ON the fan/filter switch will cause the central conditioning unit's internal fan to run continuously, whether the central conditioning unit is dehumidifying or not. This function is desirable if the central conditioning unit is used for air circulation and filtration. When the switch is ON, air will be constantly filtered through the central conditioning

unit and circulated throughout the house. When the switch is OFF, the fan will operate only when the humidity control calls for

dehumidification or when the ventilation timer calls for ventilation.

4.5 Ventilation Timer

The ventilation timer controls the fan and the motorized fresh air damper. When the ventilation timer is activated, the central conditioning unit will circulate the indoor air, and bring in fresh air from outside. The ventilation timer should be set for the required ventilation of the residence. The home should be ventilated with fresh air whenever it is occupied.

The ventilation timer is an electronic timer that displays the current time. This timer has a battery backup, so it will not require resetting after a power outage. The one minute time increments of the ventilation timer allow you to program the ventilation of your home to fit your schedule.

The ventilation timer has six programs with each program having one “on” and one “off” event. A program allows the user to turn the ventilation on at a certain day and time, then it allows them to turn the ventilation off at a certain day and time. Each of these programs can be repeated daily or weekly or during a specified block of days. All six of the programs operate independently of each other.

If the timer fails to operate or operates erratically, check that the control panel receives 24Vac from the Ultra-Aire . If 24Vac is present at the control panel, reset the timer by pressing the reset button at the bottom center of the timer face. The reset button is the small recessed button with an R beneath it located below the 1…7 and h buttons. Press the reset button in until the display disappears. Release the reset button. The display will reappear as 00:00. Resetting the timer will clear the time and all program settings. After resetting the timer, follow the instructions below to set the correct time and ventilation programs.

The following instructions explain how to set the ventilation timer. First, set the correct time on the timer by sliding the switch in the upper right hand corner of the timer to the clock symbol + and pressing the 1…7 (DAY), h (HOUR), and m (MINUTE) buttons. Remember that this timer operates on a 24-hour (military time) clock.

Next, set the ventilation time schedule. Slide the switch in the upper right hand corner to the program symbol P “ON” will appear to the right of the time and the number “1” will appear in the lower right hand corner of the display. The “1” and “ON” signify the turn on time for the first program. Press the 1…7 button to choose the days of the week for this program. You can choose Mon-Sun Mon-Fri, Sat-Sun, or any single day of the week. The days chosen are shown along the top of the display on the ventilation timer. Next press the h button to set the hour for the start of the ventilation period. Remember that this timer operates on a 24-hour clock. Then press the m button to set the minutes past the hour to start the ventilation. Now, with the ventilation start time set, press the I/O button. The word “OFF” should appear to the right of the time

7

Ultra-Aire 100V Installer’s & Owner’s Manual

Image 7
Contents Serial No DehumidificationFresh Air Ventilation Air FiltrationTable of Contents Safety Precautions Safety PrecautionsIntended Application for Ultra-Aire For Hvac Installer onlySpecifications Installation4C Ducting for Fresh Air Controls Quiet InstallationHumidity/Fan Control Panel Ventilation Timer Ventilation Timer and Humidity Control PanelHumidity Control Adjustment Fan/Filter SwitchHigh Efficiency Air filter DEH 3000 Digital Control 2B Wiring 2A Install InstructionsDEH 3000 Digital Control Installation Instructions Engage A/C during dehumidification 2C Auxiliary relay operation2D Dehumidifier lockout/activation AC sensor Dehumidification2E Location 2F Testing3D Setting Clock Time For Hvac Installer and Homeowner3B Setting 3C On/Off Setting3F Fan Setting and Operation For Hvac Installer only and HomeownerOperation 3H Intermittent or Programmed Ventilation 3J Default Settings 3I Temperature Cutout ProgrammingService Maintenance6A Checking Compressor Motor Circuits Fan ReplacementCompressor/Capacitor Replacement Refrigerant Charging7A Humidity Control Remote Controls6B Replacing a Burned Out Compressor 6C Replacing a Compressor, Nonburn OutDefrost Thermostat 7B Programmable Ventilation TimerElectric Ventilation Damper ULTRA-AIR 100V Electrical Schematic ULTRA-AIRE 100V Pictorial Electrical Diagram QTY ULTRA-AIRE 100V Service Parts List28 30 33 29 30 33 36 ULTRA-AIRE 100V Optional Parts ListULTRA-AIRE 100V External Insulation KIT ULTRA-AIRE 100V Control Panel Installation ULTRA-AIRE 100V Dehumidifier Limited Warranty PO Box 8680 Madison, WI Phone 608-222-5301 Fax

Ultra-Aire 100V specifications

The Ultra-Aire 100V by Therma-Stor Products Group is a powerful and efficient ventilating dehumidifier designed to tackle excess moisture in residential spaces. Known for its compact design and advanced technology, the Ultra-Aire 100V is an ideal solution for basements, crawl spaces, and high humidity areas.

One of the main features of the Ultra-Aire 100V is its high extraction capacity. With the ability to remove up to 100 pints of moisture per day, it effectively manages humidity levels, helping to prevent mold growth, mildew, and structural damage. This unit is equipped with an energy-efficient compressor that ensures optimum performance while minimizing energy consumption, making it an environmentally friendly choice for homeowners.

In addition to its powerful dehumidification capabilities, the Ultra-Aire 100V incorporates innovative technologies for enhanced functionality. The unit is designed with a built-in digital humidity control system, allowing users to set their desired humidity level with precision. The humidity control automatically adjusts the unit's operation, ensuring consistent moisture levels throughout the home.

Another key characteristic of the Ultra-Aire 100V is its convenience in installation and operation. The unit can be ducted into existing HVAC systems or operated as a standalone unit, providing flexibility to fit various home configurations. Its compact size also makes it easy to install in tight spaces, such as crawl spaces and attics, without sacrificing performance.

For added convenience, the Ultra-Aire 100V features a user-friendly interface. The digital display provides clear visibility of the current humidity level and operational status, while the built-in timer allows for programming operational schedules. This means homeowners can set the dehumidifier to run during specific times, optimizing performance and energy usage.

Durability is another hallmark of the Ultra-Aire 100V. Constructed with high-quality materials, this unit is built to withstand the challenges of damp environments, ensuring long-lasting performance. Additionally, its advanced filtration system captures airborne particles, improving indoor air quality by removing allergens and dust.

In conclusion, the Therma-Stor Products Group Ultra-Aire 100V stands out as a reliable dehumidification solution. With its high extraction capacity, energy-efficient operation, user-friendly controls, and durable build, this dehumidifier is an excellent choice for homeowners seeking to maintain a healthy and comfortable indoor environment. Whether combating humidity in a basement or managing moisture in a crawl space, the Ultra-Aire 100V proves to be an indispensable tool for humidity control.