Goodman Mfg PG 15 specifications Maintenance, Flame Sensor

Page 17

NOTE: Some electronic thermostats also have a built-in compressor short cycle timer that may be longer than the three minute delay given above. If you are using an electronic thermostat and the compressor has not started after three minutes, wait an additional five minutes to allow the thermostat to complete its short cycle delay time.

HIGH PRESSURE SWITCH/LOSS OF CHARGE SWITCH

Some models include a high pressure cutout switch and/or a loss of charge cutout switch. The high pressure cutout switch protects the refrigeration system from excessive operating pressures. The loss of charge cutout switch protects the refrigeration system from very low operating pressures due to a loss of refrigerant. Compressor operation will be disabled if either of these devices opens. If either devices opens, the diagnostic red LED will flash (9) times to indicate that a refrigeration system pressure switch is open.

MAINTENANCE

Have the gas heating section of the unit checked at least once a year before the heating season begins, to be sure that the combustion air inlet and flue outlet hoods are not blocked by debris, which would prevent adequate combustion air and a properly operating vent system.

FILTER REPLACEMENT OR CLEANING

A return air filter is not supplied with this unit; however, there must be a means of filtering all of the return air. The filter(s) may be located in the return air duct(s), or return air filter grille(s). Consult with your installing dealer for the actual location of the return air filter(s) for your unit.

Dirty filters are the most common cause of inadequate heating or cooling performance. Filter inspection should be made at least every two months; more often if necessary because of local conditions and usage.

Dirty throwaway filters should be discarded and replaced with a new, clean filter. Dirty permanent filters should be washed with water, thoroughly dried and sprayed with a filter adhesive before being reinstalled. (Filter adhesives may be found at many hardware stores.) Permanent filters should last several years. However, should one become torn or uncleanable, it should be replaced.

CABINET FINISH MAINTENANCE

Use a fine grade automotive wax on the cabinet finish to maintain the finish’s original high luster. This is especially important in installations with extended periods of direct sunlight.

CLEAN OUTSIDE COIL (QUALIFIED SERVICER ONLY)

The coil with the outside air flowing over it should be inspected annually and cleaned as frequently as necessary to keep the finned areas free of lint, hair and debris.

CONDENSER, EVAPORATOR, AND INDUCED DRAFT MOTORS

Bearings on the air circulating blower motor, condenser motor and the combustion fan motor are permanently lubricated. No additional oiling is required.

FLAME SENSOR (QUALIFIED SERVICER ONLY)

A drop in the flame current can be caused by a nearly invisible coating on the flame sensor. This coating, created by the fuel or combustion air supply, can be removed by carefully cleaning the flame sensor with steel wool.

NOTE: After cleaning, the microamp signal should be stable and in the range of 4 - 6 microamps DC.

Flame

Sensor

Flame Sensor

FLUE PASSAGES (QUALIFIED SERVICER ONLY)

At the start of each heating season, inspect and, if necessary, clean the unit flue passage.

CLEANING FLUE PASSAGES (QUALIFIED SERVICER ONLY)

1.Shut off electric power and gas supply to the unit.

2.Remove burner assembly by disconnecting the gas line and removing the manifold bracket from the partition panel.

3.Remove the flue from the induced draft blower and the collector box cover from the partition panel.

4.The primary heat exchanger tubes can be cleaned using a round wire brush attached to a length of high grade stainless steel cable, such as drain cleanout cable. Attach a variable speed reversible drill to the other end of the spring cable. Slowly rotate the cable with the drill and insert it into one of the primary heat exchanger tubes. While reversing the drill, work the cable in and out several times to obtain sufficient cleaning. Use a large cable for the large tube, and then repeat the operation with a small cable for the smaller tube. Repeat for each tube.

5.When all heat exchanger tubes have been cleaned, replace the parts in the reverse order in which they were removed.

6.To reduce the chances of repeated fouling of the heat exchanger, perform the steps listed in “Startup, Adjustments, and Checks”.

17

Image 17
Contents Ansi Z21.47CSA-2.3 Central Furnaces PG 15 Seer M SeriesIndex Index Safety Instructions Replacement PartsUnit Location Outside Slab InstallationRoof Curb Installation Rooftop InstallationGAS Piping Rigging DetailsRigging Natural Gas ConnectionTypical Propane Gas Piping Proper Piping PracticePropane Gas Pipe Sizing Electrical WiringTwo-Stage Heating with Two-Stage Cooling Thermostat Diagram Horizontal Air Flow Duct Cover Installation Down Discharge ApplicationsCirculating AIR and Filters Venting Filter InstallationCondensate Drain Drain ConnectionHeat Anticipator Setting STARTUP, ADJUSTMENTS, and ChecksNormal Sequences of Operation Rollout Protection ControlWith Power And Gas On With Power And Gas OffSecondary Limit Control Pre-Operation Checks Gas Supply And Manifold CheckBlower Speed Adjustments Temperature Rise CheckManifold Gas Pressure Range Nominal Gas Input Natural Gas Only CheckTroubleshooting Check wiring Flame Sensor MaintenanceManifold Assembly Accessories and Functional PartsFunctional Parts List Burner FlameAppendix Ignition Control Diagnostic Indicator Chart Dimension Medium Large YL/BK BL/PK LPS 0140G00533 REV a PG15*****41B* Wiring Diagram PG15*****41B* Wiring Diagram Ton 2 Ton 2 -/ 4 Ton Unit= Outside of Temperature Rise Range Not Recommended Before Calling Your Servicer

PG 15 specifications

Goodman Manufacturing's PG 15 series stands out in the competitive HVAC market as a high-efficiency, cost-effective option for both residential and light commercial applications. This product line is particularly valued for its reliable performance and innovative technologies, which focus on energy efficiency, durability, and user comfort.

One of the main features of the PG 15 is its SEER (Seasonal Energy Efficiency Ratio) rating, which reflects its ability to provide superior cooling while using less energy. The higher the SEER rating, the more efficiently the unit operates, leading to significant savings on energy bills. The PG 15 boasts an impressive SEER rating, making it an ideal choice for conscientious consumers looking to lower their utility costs.

Incorporating advanced technologies, the PG 15 features a high-efficiency scroll compressor. This design minimizes vibration and noise, providing a quieter operation that enhances overall comfort in the living or working environment. Additionally, the compressor is designed for longevity, reducing maintenance needs and enhancing the unit's lifespan.

Another notable characteristic of the PG 15 is its durable construction. The unit is built with a galvanized steel cabinet that is protected with a rust-resistant finish, ensuring it withstands the rigors of harsh weather conditions. The 15-inch fan motor and multi-speed blower also contribute to efficient airflow and improved indoor air quality, while the refrigerant management system aids in efficient cooling performance.

Installation versatility is another advantage of the PG 15 series. Designed to accommodate a range of installation setups, this system can easily integrate into existing frameworks, making it suitable for both new constructions and retrofits.

Furthermore, Goodman Mfg places emphasis on customer satisfaction and support. The PG 15 series comes with a comprehensive warranty, offering peace of mind to homeowners and business owners alike. This commitment to quality and customer service has helped Goodman establish a reputation for reliability and performance in the HVAC industry.

In summary, the Goodman PG 15 stands out due to its energy-efficient design, advanced technologies, durable construction, and versatile installation options, making it a compelling choice for anyone seeking an effective and reliable HVAC solution.