Oakleaf Woodburning Stove
CLEARANCE TO COMBUSTIBLES: Corner Installation, Vertical Vent
| Location |
|
A | Shield Corner to Wall | 14" / 356 mm |
B | Vent Pipe to Wall | 21.75" / 552 mm |
Pipe clearance may be reduced using double wall or insulat- ed connector pipe, provided that you adhere to the specified clearances from the stove itself. Follow pipe manufacturer's guidelines.
B
| B |
|
|
| A | A | B |
|
| ||
A | CLEARANCE TO COMBUSTIBLES: Corner Installation | ||
| Vertical Vent, Horizontal Exit |
| |
|
| Location |
|
| A | Shield Corner to Wall | 14" / 356 mm |
| B | Vent Pipe to Wall | 21.75" / 552 mm |
*For clearance reduction methods, refer to NFPA 211 or Local Codes
CLEARANCE TO COMBUSTIBLES: Horizontal Venting Configuration
Location
AUnit to Side Wall
B Unit to Back Wall
C Vent Pipe to Side Wall
17" / 432 mm 13" / 330 mm 26.5" / 673 mm
| Corner Installation |
|
D | Shield Corner to Wall | 14" / 356 mm |
E | NFPA 211 specifies clearance of | 18" / 457 mm |
(Although vent clearance may be reduced using
NOTICE: When using rear flue configuration, a new upper rear heat shield,
| C |
|
|
| A | B |
|
|
|
| |
|
| D | E |
Save These Instructions | Dry Seasoned Wood Only! | 11 |