Harman Stove Company 1-90-79700 3Getting Started, Design, Installation & Location Considerations

Page 6

Oakleaf Woodburning Stove

3Getting Started

A. Design, Installation & Location Considerations

1. Appliance Location

Consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation. When installing on a combustible floor, the optional bottom heat shield must be installed along with using proper floor protection material. See page 12 for details.

Maintain specified vent clearance to combustible requirements listed by the vent manufacturers instructions and all clearance to combustibles listed in this manual.

Check with your local building code agency before you begin your installation. Be sure local codes do not supersede UL specifications and always obtain the required permit so that insurance protection benefits cannot be unexpectedly cancelled. If any assistance is required during installation, please contact your dealer.

We recommend that a qualified building inspector and your insurance company representative review your plans before and after the installation.

Be sure to provide a source of fresh air to the room or directly to the appliance. Make-up air is needed to replace what the chimney draws away through the appliance.

CAUTION

Do NOT connect this unit to a chimney flue servicing another appliance.

Do NOT connect to any forced air distribution duct or system.

B. Fire Safety

Maintain the designated clearances to combustibles. Insulation must not touch the chimney. You must maintain the designated air space around the chimney. This space around a chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing. NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction.

To provide reasonable fire safety, the following should be given serious consideration:

1.Install at least one smoke detector on each floor of your home. Detectors should be located away from the heating appliance and close to sleeping areas. Follow the smoke detector manufacturer's placement and installation instructions, and be sure to maintain regularly.

2.A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers.

3.A practiced evacuation plan, consisting of at least two escape routes.

4.A plan to deal with a chimney fire as follows: In the event of a chimney fire:

a.Evacuate the house immediately.

b.Notify Fire Department.

c.Never apply water to a suspected chimney fire. Serious damage could occur.

WARNING

Fire Hazard

Do not operate appliance before reading and understanding the operating instructions.

Failure to operate properly may cause a house fire.

6 Dry Seasoned Wood Only!

3-90-798

Save These Instructions

Image 6
Contents Installation and Operation Do Not DiscardOakleaf Woodburning Stove Table of Contents This appliance is also approved for installation in a shop 1Listing and Code ApprovalsMobile Home Approved If the alarm sounds 2Special Warnings and Notes3Getting Started Design, Installation & Location ConsiderationsFire Safety Appliance LocationComponent Locations Flue Direction ConversionPre- Use Check List Fire Risk4Dimensions & Clearances Appliance DimensionsClearances To Combustibles 17 / 432 mm 14 / 356 mm 26.75 / 679 mm *17.5 / 444 mmClearance to Combustibles Corner Installation Floor Protection Floor Protection RequirementsFloor Protection Requirements RequirementsDraft Chimney ConnectorsChimneys and Venting Wall Pass-thrusChimney 3-foot, 2-foot, 10 foot ruleVenting to a Masonry Chimney Installing to a Prefabricated ChimneyExisting Masonry Chimneys Venting to a Masonry Fireplace ChimneyAttic Factory-BuiltShield Metal ChimneyAirtight insulated Clean- out Oakleaf Woodburning Stove Full Relining Fireplace Conversion Freestanding Appliance Chimney Breach Fireplace Conversion with Combustible Wall Mobile Home Installation 6Mobile HomeLeveling the Appliance 7Appliance Set-UpOutside Air Attachment Optional Cooking GrillOptional Blower Installation Optional Rear-vent Rear ShieldOptional Bottom Heat Shield 8Operating Instructions Fuel SpecificationsAlways wear fire retardant gloves When operating the stove General Operating InformationDoors Or change the configuration of this grate systemCombustion Process GratesUser Controls Before Your First FireBuilding and Maintaining a Fire Oakleaf Woodburning Stove Service & Maintenance Seasonal cleaningCreosote- Formation and Need For Removal By User Wear Leather Gloves To Prevent Skin Burns General Maintenance ProceduresAsh Removal Door GlassBlower- If installed FireboxChimney Oakleaf Optional Blower Kit #1-00-797032 Wiring Diagram 10Reference MaterialsService parts Part number list on followingStocked At depotStocked at depot Grams Per Hour 50% 60% 70% 80% 90% 100%Limited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService & Maintenance Log Page Signature of Boxer Proudly Printed On 100% Recycled Paper