Harman Stove Company 1-90-79700 Service & Maintenance, Creosote- Formation and Need For Removal

Page 28

Oakleaf Woodburning Stove

9

 

Solid fuel burning spave heaters must be cleaned regularly,

Service & Maintenance

as soot, ash and creosote may accumulate.

 

 

 

A.Creosote- Formation and Need For Removal;

When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney and chimney connector should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire.

If you experience a chimney fire; Close the air control and bypass damper and notify the fire department. Do NOT apply water to the fire, in the firebox or in the chimney. Do not operate the appliance until the chimney and connector have been inspected and approved by a chimney professional.

Do not burn any fuel other than wood, such as charcoal, which can cause increased carbon monoxide production or overfiring. Never use highly volatile substances in your stove, such as gasoline, which could cause an explosion.

When solid fuels are burned completely, they produce water and carbon dioxide. However, in long slow burns, a substantial amount of carbon monoxide may be produced. If allowed to build up, carbon monoxide (which is odorless) can prove fatally poisonous. Proper ventilation and draft will prevent this from happening. If you smell smoke, turn up the air control lever setting, and thoroughly ventilate your dwelling. During future burns, be careful not to overload the stove with fuel, so you will not be tempted to constantly operate at a low air control setting.

Other causes of poor ventilation or draft are icing, exhaust fans, a blocked outside air inlet, and room air starvation. If your stove is sluggish and you get occasional odor, check these possibilities and increase the air flow in your home.

Seasonal cleaning

At least once per year, the stove, venting connectors and chimney should be thoroughly cleaned. If the areas are found to have an excessive build up of ash or creosote, it is recommended to increase the frequency of the cleaning. This will extend the life of the appliance and its components. A vacuum specifically designed for ash is preferred, however a standard shop-style vacuum with a HEPA filter may also work just fine.

During cleaning, caution must be taken not to damage the white / gray colored ceramic combustion package in the rear of the firebox. When using a brush in the chimney or venting connector, the by-pass damper should be placed in the open position to help prevent ash, creosote or other debris from falling down onto and around the combustion package. This also protects the top of the combustion package from tool or brush damage and diverts most of the removed materials into the firebox for easy clean-up and removal. Once the venting system has been cleaned, remove the first section of connector pipe from the appliance flue collar. Carefully vacuum the ash and debris from around the sides and top of the combustion package.

The shoe brick must be removed to allow vacuum access for cleaning the front portion of the combustion package.

Always use caution when refueling or when vacuuming the firebox and combustion package. Some users have damaged their combustion package with vacuum cleaner tools, and fire pokers.

Caution: Always wear fire-resistant gloves to operate the stove. The air control is hot while in operation.

28 Dry Seasoned Wood Only!

3-90-798

Save These Instructions

Image 28
Contents Installation and Operation Do Not DiscardOakleaf Woodburning Stove Table of Contents 1Listing and Code Approvals This appliance is also approved for installation in a shopMobile Home Approved If the alarm sounds 2Special Warnings and NotesDesign, Installation & Location Considerations Fire Safety3Getting Started Appliance LocationComponent Locations Flue Direction ConversionPre- Use Check List Fire Risk4Dimensions & Clearances Appliance DimensionsClearances To Combustibles 17 / 432 mm 14 / 356 mm 26.75 / 679 mm *17.5 / 444 mmClearance to Combustibles Corner Installation Floor Protection Requirements Floor Protection RequirementsFloor Protection RequirementsChimney Connectors Chimneys and VentingDraft Wall Pass-thrusChimney 3-foot, 2-foot, 10 foot ruleInstalling to a Prefabricated Chimney Existing Masonry ChimneysVenting to a Masonry Chimney Venting to a Masonry Fireplace ChimneyFactory-Built ShieldAttic Metal ChimneyAirtight insulated Clean- out Oakleaf Woodburning Stove Full Relining Fireplace Conversion Freestanding Appliance Chimney Breach Fireplace Conversion with Combustible Wall Mobile Home Installation 6Mobile Home7Appliance Set-Up Outside Air AttachmentLeveling the Appliance Optional Cooking GrillOptional Rear-vent Rear Shield Optional Blower InstallationOptional Bottom Heat Shield Fuel Specifications Always wear fire retardant gloves When operating the stove8Operating Instructions General Operating InformationOr change the configuration of this grate system Combustion ProcessDoors GratesBefore Your First Fire User ControlsBuilding and Maintaining a Fire Oakleaf Woodburning Stove Seasonal cleaning Service & MaintenanceCreosote- Formation and Need For Removal General Maintenance Procedures Ash RemovalBy User Wear Leather Gloves To Prevent Skin Burns Door GlassFirebox Blower- If installedChimney Oakleaf Optional Blower Kit #1-00-797032 Wiring Diagram 10Reference MaterialsService parts Part number list on followingStocked At depotStocked at depot Grams Per Hour 50% 60% 70% 80% 90% 100%Limited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService & Maintenance Log Page Signature of Boxer Proudly Printed On 100% Recycled Paper