BEFORE OPERATING

Gas Pressure Requirements

Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient performance of this appliance. Make sure that the plumber or gas supplier checks the gas sup- ply line and gas pressure at installation.

NOTE: Improper gas pressure can affect heater performance, flame color, or cause pilot outage.

Natural Gas:

Maximum inlet pressure 7.0" w.c. (1.74 kPa) Minimum inlet pressure 5.0" w.c. (1.25 kPa) Gas manifold pressure 3.5" w.c. (0.87 kPa)

LPG Gas:

Maximum inlet pressure 13" w.c. (3.24 kPa) Minimum inlet pressure 11" w.c. (2.74 kPa) Gas manifold pressure 10" w.c. (2.49 kPa)

DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER OR EXPOSED TO MOIS- TURE CORROSION. IMMEDIATELY CALL A QUALlFlED SERVICE TECHNICIAN TO INSPECT THE HEATER AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.

NE PAS SESERVIRDE CET APPAREIL S'IL A ÉTRE PLONGÉ DANS L'EAU, COMPLÉTEMENT OU EN PARTIE. APPELER UN TECHNICIEN QUALIFIÉ POUR INSPECTER L'APPAREIL ET REMPLACER TOUTEPARTIE DU SYSTÈME DE CONTRÔLE ET TOUTECOMMANDEQUIONT ÉTÉPLONGÉSDANS L'LAU.

CONNECTING THE CORDSET

RECOMMENDED GAS PIPE DIAMETER

 

Pipe Length

Schedule 40 Pipe

Tubing, Type L

(Feet)

Inside Diameter

Outside Diameter

 

N.G.

L.P.

N.G.

L.P.

0-10

1/2"

3/8"

1/2"

3/8"

 

1.3

cm

1.0

cm

1.3

cm

1.0

cm

10-40

1/2"

1/2"

5/8"

1/2"

 

1.3

cm

1.3

cm

1.6

cm

1.3

cm

40-100

1/2"

1/2"

3/4"

1/2"

 

1.3

cm

1.3

cm

1.6

cm

1.3

cm

100-150

3/4"

1/2"

7/8"

3/4"

 

2.0

cm

1.3

cm

2.3

cm

2.0

cm

NOTE: NEVER USE PLASTIC PIPE. CHECK TO CONFIRM WHETHER YOUR LOCAL CODES ALLOW

COPPER TUBING OR GALVANIZED PIPE.

9

The Clarity Fireplace Insert, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the the current edition of the National Electrical Code, ANSI/NFPA 70 in the United States or the current Canadian Electrical Code CSA 22.1 in Canada.

This appliance is equipped with a three-prong (grounding) plug for protection against shock haz- ard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or re- move the grounding prong from the plug.

NOTE: The convection fan requires a 120 VAC supply for operation, but the heater can be operated without the fan as in the case of a power outage.

Plug the 3-prong grounded electrical cord plug into the wall outlet.

CONNECTING THE

OPTIONAL THERMOSTAT

If the optional thermostat is used, it must be plugged into the terminal strip located behind the right side air inlet grill. It can be accessed by first opening the control access door and then pulling up and forward on the air grill. The terminal block will then be visible.

When installing a millivolt control system, use only a special low resistance thermostat. Do not use a regular heating thermostat.

Be sure that all electrical connections are clean, free from corrosion, and tight. Inspect connections periodically to confirm that no corrosion has built up over time.

When properly installed and maintained, a mil- livolt control system should give many years of trouble-free service.

It is important to use wire of a gauge proper for the length of the wire:

RECOMMENDED WIRE GAUGES

Maximum

Wire

Length

Gauge

100'

14

60'

16

40'

18

25'

20

15'

22

INSTALLING THE INSERT

Image 9
Contents Harman Clarity 828i Gas Fireplace Insert Page Table of Contents Introduction .2 Gas Appliance Installation CodeClearances InstallationConnecting the Clarity Fireplace VentingTest for Flue Spillage Removing the Glass door AssemblyInsert to a GAS Supply Natural PropaneConnecting the Cordset Connecting Optional ThermostatInstalling the Insert Into the Fireplace AIR Shutter AdjustmentMonitoring the GAS Flame HOW to Light the FireRemoving the Glass Door Trim Panels MaintenanceReplacing the Gasket Inspecting the VentingCleaning the Glass Cleaning the LOG SET and FireboxConvection Blower Service Access Page Conversion KIT Components Appendix a Fuel ConversionAppendix B De-rating for High Altitude Appendix C Changing Orifices Appendix D Low Voltage Wiring Diagram Volt Wiring Diagram Parts List Burner Assembly Page Specifications Natural GAS PropaneMinimum Clearances from Combustible Construction Year Limited Warranty Commercial

828i specifications

Harman Stove Company has long been a respected name in the realm of heating solutions, and their 828i model is no exception. This innovative pellet stove embodies the perfect blend of technology, efficiency, and aesthetic appeal.

The Harman 828i features a sleek design, making it suitable for various home decors while providing optimal heating performance. With a heat output of up to 68,000 BTUs, it can effectively warm spaces ranging from 1,500 to 3,000 square feet, making it ideal for both residential and commercial applications. One of the most appreciated features of the 828i is its large hopper capacity, capable of holding up to 50 pounds of pellets. This translates to extended burn times and less frequent refueling, which is convenient for users.

One standout technology in the 828i is the Smart Control panel, which facilitates easy operation and allows users to program their heating preferences. With this advanced control system, users can set different heating schedules, maximizing comfort and efficiency while minimizing fuel consumption. Additionally, the stove is equipped with an intelligent temperature sensor that helps maintain a consistent temperature, further enhancing its efficiency.

The 828i also boasts a unique heat exchanger design that promotes superior heat transfer while minimizing emissions. Harman has incorporated their signature Emission-Reduction Technology, which ensures that the stove operates with a low environmental impact. This commitment to sustainability is evident in the high-efficiency ratings the stove achieves, often exceeding 80%.

For those who prioritize easy maintenance, the 828i is designed with user-friendly access for cleaning and service. The removable ash pan makes ash disposal straightforward, while the self-maintaining features of the stove reduce the need for frequent cleaning.

Overall, the Harman Stove Company 828i stands out in the crowded pellet stove market with its efficient heating capabilities, advanced technology, and thoughtful design. Whether for a cozy home or a larger commercial space, the 828i promises reliable warmth and impressive performance, making it a worthy investment for any heating needs. Its combination of modern aesthetics and cutting-edge function means it fits seamlessly into any environment while delivering the quality and reliability that Harman is known for.