Harman Stove Company HB 38 DV manual Introduction

Page 4

Introduction

The Harman Serenity III Direct Vent Gas Fire- place isa listed gas-fired directvent room fireplace tested by Intertek Testing Services/Warnock Hersey to ANSI Z21.88-2002/ CSA2.33-M02. CAN-CGA-2.17- M91.

The installation of the Serenity III Direct Vent Gas Fireplace must conform with local codes, or in the ab-

sence of local codes, with National Fuel Gas Code, ANSI Z223.1 — latest edition and CAN 1 B1-149.1

and .2Installation Code.

Also for use in mobile (manufactured) homes after home is sited.

Mobile (manufactured) home installations must adhere to current editions of Title 24 CFR, part 3280, or CSA Z240.4.

CAUTION: This appliance must be vented to the outside.

Installationand repairof the Serenity IIIDirect Vent Gas Fireplace should be done by a qualified service per- son. The appliance should be inspected before use and at least annually by a qualified service person. More fre- quent cleaningmay be required dueto excessivelint from carpeting, bedding material, etc. It is imperative that controlcompartments, burners, and circulatingair pas-

Due to high temperatures, the Serenity III Direct Vent Gas Fireplace should be located out of traffic and awayfrom furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperatures and should stay awayto avoid burns or clothing ignition.

Young children should be carefully supervised when theyare in the same room as the appliance.

Clothing or other flammable materials should not be placed on or near the appliance. Surveiller les enfants. Garder les vetements, les meubles, lessence ou autres liquides a vapeur inflammables lin de lappareil.

sageways of the Serenity III be kept clean.

When operatingyour HarmanSerenity IIIGas Fire- place, respect basic safety standards. Read these in- structions carefully before you attempt to operate the fireplace. Failure todo so may result in damage to prop- erty or personal injury and may void the product war- ranty.

Consult with your localbuilding code agency and insurance representative beforeyou begin your installa- tionto ensure compliance with localcodes, includingthe need for permits andfollow-up inspections.

Several issues must be addressed when selecting a suitable location foryour Serenity III Gas Fireplace. Ob- servingrequired clearances to combustible materials, the proximity to a safe chimneyor ventingsystem location, and the accessibility of the gasand electricalsupply must allbe considered. In addition, selecting a location that takes advantage of the building's naturalair flow is also desirable to maximize the heating effectiveness of the fireplace. In many cases, this is a centrallocation within the building.

Anysafety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.

This appliance may be installed in an aftermar- ket permanently located (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type(s) of gas indicated on the ratingplate. This appliance is not convertible for use with other gases, unless a certified kit is used.

Cet appareil peut etre installe dans un maison prefabriquee (mobile) deja installee a demeure si les reglements locaux le permettent.

Cet appareil doit etre utilise uniquement avec les types de gas indiques sur la plaque signaletique. Ne pas l utiliser avec d autres gas sauf si un kitde conversion dertifie est installe.

4

Image 4
Contents Safety Notice Harman Built Serenity HB 38 DVForyour Safety Table of Contents Introduction Important Feature Air Gate Blower System 200% To 300% More AirBlower Off Blower OnOperation OperationHOW to Turn OFF the Fire Pilot FlamesSpecifications Top Vent Rear VentMinimum Clearances from Combustible Construction This fireplace may be placed on a wood floorRear Vent Corner Top Vent Installation Options InstallationTypical Tile Facing Sectional View Installation PlacementNoncombustible Installing The Arch Face Removing The Arch FaceAssembling the Victorian Face Installing Fireplace To use Victorian Face Mounting The Victorian Face Burn Only the Fuel for which the Heater is Equipped Making The ConnectionGas Pressure Requirements Natural GasPart Numbers for SimpsonDura-Vent Pipe and Fittings Use Only Approved Venting8 x Description Venting Venting with 8 x 5 PipeRear Vent Model Approved. Never used 6 5/8 x 4 pipe for rear VentVenting with 6 5/8 x 4 Pipe Into a wallor siding Damper Settings Feet 2 toLP Conversion Kit Changing to LPTop Vent LP Kit Rear Vent LP Kit Top Rear Vent NaturalFront Rear Log Placement Installation Options Connecting Optional ThermostatOptional Remote Register Kit Register KitFloor Kit Wall KitInstalling Damper Assembly Optional Wall Register KitMount register after drywall and painting are finished Floor Register Installation Installing the Floor Register Not allow the register blower to start if Fireplace is turned off and coolsMaintenance Cleaning the GlassCleaning the Log Set and Firebox Removing the Glass FrontAir Flow Cleaning the BurnersLubrication Maintenance Verify proper operation after servicing WHI # Replacement Parts Natural Gas PropaneTrouble Shooting YesBad Replace Pirzo Ignitor Turn on gas valve Replenish supplyPilot does not stay lit GoodCheck inlet pressure Correct inlet pressureIs Pilot lit Bad Install new batteries Rear burner does not lightCheck batteries Replace solinoidLife Time

HB 38 DV specifications

The Harman Stove Company HB 38 DV is a high-performance direct vent pellet stove that is designed to meet the needs of homeowners seeking efficient and effective heating solutions. This stove is renowned for its combination of advanced technology, sleek design, and user-friendly features, making it a popular choice for both aesthetic appeal and functional heating.

One of its key features is the patented Harman burn pot design, which ensures an even burn and maximum heat output. The burn pot is engineered to minimize clinkering, allowing users to enjoy longer burn times and less frequent maintenance. The HB 38 DV not only heats efficiently but does so while using environmentally friendly wood pellets, promoting a sustainable approach to home heating.

The stove is equipped with an advanced microprocessor-controlled smart technology system. This system automatically adjusts the burn rate to match the desired temperature settings, providing optimal comfort while maintaining energy efficiency. Users can simply set their desired temperature, and the stove will automatically adjust the feed rate and combustion air to maintain that level, reducing the need for constant adjustments.

The Harman HB 38 DV also features a large viewing window, providing an inviting visualization of the flames while contributing to the room's ambiance. The stay-cool handle allows for ease of opening the door without the risk of burns. The stove is available in several finishes allowing homeowners to select a style that complements their decor.

In terms of efficiency, the HB 38 DV boasts an impressive efficiency rating of over 85%. This means that more of the fuel is converted into usable heat, leading to reduced heating costs and fewer emissions. The unit has a powerful blower that effectively distributes heat throughout the room, ensuring that the warmth is felt quickly and evenly.

The installation process is flexible due to its direct vent capability, allowing for venting through walls or ceilings. This feature enables users to install the stove in various locations within their home, maximizing both functionality and style.

In summary, the Harman Stove Company HB 38 DV combines advanced technology, efficient heating, and modern design, making it a standout option for homeowners looking for a dependable and attractive pellet stove. Its various features cater to both performance and aesthetic preferences, positioning it as a leading choice in contemporary heating solutions.