D. How to Use the Vent Graph

1.Measure the distance from the top of appliance to the center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis across until it intersects with the slanted line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.The point at which this line meets the bottom line of the graph is the maximum length of the horizontal run.

Example 1: If the vertical dimension from the top of the appliance to the center of the 90° elbow is 7 ft. (2 m), the horizontal run to the outer wall flange must not exceed 13 ft. (4 m).

Example 2: If the vertical dimension from the top of the appliance is 21 ft. (6.4 m), the horizontal run to the outer wall flange must not exceed 9 ft. (3 m).

4.Each 90° elbow is equivalent to 3 ft. (914 mm) of vent pipe and each 45° elbow is equivalent to 1 ft. (305

mm)of vent pipe, and must be subtracted from vent pipe run. A single vertical to horizontal 90° elbow is already calculated into the allowable 15 ft. (5 m) run. Each additional 90° elbow reduces the maximum horizontal distance by 3 ft. (914 mm).

Example: The use of three elbows would reduce the allowable horizontal run to 9 ft. (3 - 1 = 2 elbows x 3 ft. = 6 ft.; 15 ft. max. - 6 ft. = 9 ft. max.)

E. Venting Guidelines

The maximum horizontal vent run is 15 ft. (5 m) when the vertical vent rise is 10 ft. (3 m).

The minimum horizontal vent run is 11-5/8 in. (295 mm).

Horizontal sections require a 1/4 in. (6 mm) rise for every 12 in. (305 mm) of horizontal travel.

Horizontal sections require noncombustible support every 3 ft. (914 mm), e.g. wall strap.

Wall thickness: Minimum 4 in. (102 mm). Maximum 20 in. (508 mm).

Vent Diameter: Exterior 6-5/8 in. (168 mm); Inner 4 in. (102 mm).

EXCEPTION FOR REAR VENT KIT, HORIZONTAL INSTALLATION:

• The maximum horizontal vent run is 2 ft. (610 mm).

NOTICE: Maximum horizontal vent run is 18 in. (457 mm) when using the HRC termination cap.

The maximum horizontal vent run with a 45° elbow is 18 in. (457 mm).

No external minimum rise is required. The minimum horizontal vent run is 11-5/8 in. (295 mm).

For any vertical rise when rear venting, a minimum of 2 ft. (610 mm) vertical must be used prior to any horizontal run.

EX. 2

VERTICAL DISTANCE

FROM APPLIANCE TO THE 90º ELBOW

EX. 1

35'

 

 

 

 

 

 

 

 

34'

 

 

 

 

 

 

 

 

32'

 

 

 

 

 

 

 

 

30'

 

 

 

 

 

 

 

 

28'

 

 

 

 

 

 

 

 

26'

VENT RESTRICTOR

 

 

 

 

 

24'

 

 

 

 

 

22'

PLATE REQUIRED

 

 

 

 

 

 

 

 

 

 

 

 

 

20'

 

 

 

 

 

 

 

 

18'

 

 

 

 

 

 

 

TOTAL HORIZONTAL RUN TO

16'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTSIDE OF EXTERIOR WALL

14'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(INCLUDING ELBOWS)

12'

 

 

 

 

 

 

 

To adjust the vent restrictor

10'

 

 

 

 

 

 

 

plate, see page 34.

8'

 

 

 

 

 

 

 

 

6'

 

 

 

 

 

 

 

 

4'

 

 

 

 

 

 

 

 

2'

 

 

 

 

 

 

 

 

0'

 

 

 

 

 

 

 

 

11-5/8” 2'

4'

6'

8'

10'

12'

14'

15'

(MIN)

 

 

 

 

 

 

(MAX)

Figure 5.2

6 ft. (2 m) Minimum Vertical Termination

C

L

CL For rear vent or top of appliance for top vent.

2 ft. (610 mm) Maximum Horizontal run with no vertical pipe and with 1/4 in. (6 mm) rise per foot.

6 in. (152 mm) Minimum starter pipe

12

Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD2189-900 Rev. i • 5/12

Image 12
Contents Models What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsDesign and Installation Considerations Getting StartedTools and Supplies Needed Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationClearances to Combustibles It is permissible to place the appliance on carpetTermination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting GuidelinesHorizontal Termination Adding Venting Components203 mm 178 mm 152 mm Fold Strap Vertical Termination Continue to assemble pipe sections until the height Secure the Vent Sections Twist-lock the vent cap and sealDisassemble Vent Sections Cathedral CeilingClass a Metal Chimney Existing Masonry Chimney Type aTo determine the length of flex needed, measure from Opening in Masonry Wall Installing Slim Line Trim Ring and Heat Shield Slim Line Wall ThimbleAssembling Slim Line Trim Ring and Heat Shield FIG. C Minimum Clearance Gas Information Fuel ConversionGas Pressures Gas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceIntelliFire Ignition System Wiring Wire Size Max. LengthLoss of Power and Battery Backup Usage Wall Switch Installation for Fan Optional Junction Box Wired to Wall SwitchAppliance Setup Remove Shipping MaterialsUnbolting Appliance from the Pallet Accessories Leveling and Lagging Down the ApplianceTop to Rear Vent Conversion Shutter Adjustment Installing the Vent RestrictorAir Shutter Settings Installing Rock Media and Ember Material InstallationLeft Rock Cluster Installation precautions Optional BlowerFAN Base Contacts FAN Bracket Recommended operating procedures 28 Blower Wiring DiagramRemote Controls Installing flame control solenoidRemote receiver Wiring the flame control solenoid REDFront Door Glass Assembly Replacement Inner Glass Door Assembly ReplacementOperating Instructions Before Lighting ApplianceControls Lighting Instructions IPI Final inspection byFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Ues to spark, and main Maintaining and Servicing Appliance Before servicingMaintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsHearth Pad Vent Components Diagram SLP Series Vent ComponentsVent Components List ComponentsRock Placement Service PartsPart number list on following Service Parts List StockedAt Depot #22 Bottom Plate Assembly NGK-DXV Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information

PALOMA-BZ-MOD specifications

The Heat & Glo LifeStyle PALOMA-BZ-MOD is an innovative and stylish gas fireplace designed to elevate the ambiance of any living space. This modern fireplace combines functionality, aesthetics, and advanced technology, making it an ideal choice for homeowners seeking both warmth and sophistication.

One of the standout features of the PALOMA-BZ-MOD is its contemporary design. With its clean lines and minimalist profile, this fireplace seamlessly integrates into various interior styles—from ultra-modern to classic decor. The wide viewing area provided by the expansive glass front ensures that the mesmerizing flames are the focal point of any room, creating an inviting and cozy atmosphere.

The PALOMA-BZ-MOD incorporates advanced heating technologies that enhance efficiency and performance. Its powerful heating capacity can warm spaces effectively, allowing for comfortable living even in colder climates. The unit is designed to operate quietly, ensuring that the crackling flames are the only sound you hear. This makes it perfect for homes where relaxation and tranquility are priorities.

Another noteworthy aspect of the PALOMA-BZ-MOD is its customizable features. Homeowners can choose from a variety of decorative media options, including ceramic logs, glass beads, or pebbles, allowing for personalization that complements individual style preferences. The flame presentation is adjustable, giving users control over the height and intensity of the flames, thus enhancing both aesthetics and functionality.

The fireplace is equipped with innovative technologies for ease of use. The flexible installation options mean it can be placed in a variety of locations, whether it's a central feature in a living room or an elegant addition to a dining area. Additionally, a user-friendly remote control allows for convenient operation, enabling users to turn the fireplace on or off and adjust settings from across the room.

Safety is a priority with the PALOMA-BZ-MOD. It features an advanced safety shut-off system, ensuring peace of mind for homeowners. The continuous pilot light and electronic ignition system enhance reliability, providing instant warmth when needed.

In summary, the Heat & Glo LifeStyle PALOMA-BZ-MOD exemplifies a harmonious blend of modern design and advanced technology. With its captivating flames, customizable features, and efficient heating performance, it serves as both a functional heating solution and a stunning piece of decor, making it a popular choice for any contemporary home.