STUDWALL

10 in. x 10 in.

(254 mm x 254 mm)

FRAMED OPENING IN WALL

RETRO

CONNECTOR

MASONRY CHIMNEY

4.

To determine the length of flex needed, measure from

 

3 in. (76 mm) above the top of the flashing down to the

 

level of the opening. Add the distance from the center

 

of the chimney out through the wall. Cut a piece of 4

 

in. (102 mm) flex to this length (extended to its nominal

 

length). Be sure to leave 2-3 in. (51-76 mm) of flex

 

above the existing chimney to allow for connection to

 

the termination kit.

5.

Connect the flex liner to the top adapter using four

 

sheet metal screws (Figure 5.21).

6.

Feed the flex liner through the flashing into the

 

chimney. Carefully feed the flex liner down the chimney

FOUR MASONRY BOLTS

WALL THIMBLE COVER

(NOT INCLUDED)

 

NOTE: For hearth applications refer to page 20, Figure 5.24 for the use of the 923GCL co-axial to co-linear appliance con- nector.

Figure 5.25

3.Secure the flashing to the top of the masonry chimney using a bead of non-hardening sealant-adhesive. If the flashing is larger than the top of the chimney, cut and fold flashing as needed to fit chimney (Figure 5.26).

CUT AND BEND FLASHING

AS NEEDED TO FIT CHIMNEY

SEALANT-ADHESIVE

Figure 5.26

to the bottom and out the opening in the masonry wall,

forming an angle to line up the flex liner with the vent

opening on the appliance.

WARNING

Fire Risk. Explosion Risk.

Do not let the flex liner sag below the level at which it will connect to the appliance or connector. This could allow hot gas to become trapped and potentially become a fire hazard. The flex liner path should always be sloped up toward the termination cap.

7.If additional lengths of flex liner are needed to span the chimney height, use a flex coupler to connect the pieces of flex liner together. Connect the flex to the coupler by using four sheet metal screws for each side (Figure 5.27).

FLEX LINER

FLEX COUPLER

SHEET METAL SCREWS

Figure 5.27

8.Secure the top adapter to the flashing. Use three sheet metal screws through the side of the top adapter into the flange on the flashing (Figure 5.28). Twist lock the high wind termination cap on to the top adapter.

22

Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD2189-900 Rev. i • 5/12

Image 22
Contents Models What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsTools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationClearances to Combustibles It is permissible to place the appliance on carpetTermination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsHow to Use the Vent Graph Venting GuidelinesHorizontal Termination Adding Venting Components203 mm 178 mm 152 mm Fold Strap Vertical Termination Continue to assemble pipe sections until the height Secure the Vent Sections Twist-lock the vent cap and sealDisassemble Vent Sections Cathedral CeilingClass a Metal Chimney Existing Masonry Chimney Type aTo determine the length of flex needed, measure from Opening in Masonry Wall Slim Line Wall Thimble Installing Slim Line Trim Ring and Heat ShieldAssembling Slim Line Trim Ring and Heat Shield FIG. C Minimum Clearance Fuel Conversion Gas InformationGas Pressures Gas Connection Check for GAS LeaksIntelliFire Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthLoss of Power and Battery Backup Usage Wall Switch Installation for Fan Optional Junction Box Wired to Wall SwitchRemove Shipping Materials Appliance SetupUnbolting Appliance from the Pallet Accessories Leveling and Lagging Down the ApplianceTop to Rear Vent Conversion Installing the Vent Restrictor Shutter AdjustmentAir Shutter Settings Installing Rock Media and Ember Material InstallationLeft Rock Cluster Installation precautions Optional BlowerFAN Base Contacts FAN Bracket Recommended operating procedures 28 Blower Wiring DiagramInstalling flame control solenoid Remote ControlsRemote receiver Wiring the flame control solenoid REDFront Door Glass Assembly Replacement Inner Glass Door Assembly ReplacementBefore Lighting Appliance Operating InstructionsControls Lighting Instructions IPI Final inspection byInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Ignition System Ues to spark, and main Maintaining and Servicing Appliance Before servicingMaintenance Tasks Inspect Maintenance TasksReference Materials Appliance Dimension DiagramHearth Pad Vent Components Diagram SLP Series Vent ComponentsVent Components List ComponentsService Parts Rock PlacementPart number list on following Stocked Service Parts ListAt Depot #22 Bottom Plate Assembly NGK-DXV Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information

PALOMA-BZ-MOD specifications

The Heat & Glo LifeStyle PALOMA-BZ-MOD is an innovative and stylish gas fireplace designed to elevate the ambiance of any living space. This modern fireplace combines functionality, aesthetics, and advanced technology, making it an ideal choice for homeowners seeking both warmth and sophistication.

One of the standout features of the PALOMA-BZ-MOD is its contemporary design. With its clean lines and minimalist profile, this fireplace seamlessly integrates into various interior styles—from ultra-modern to classic decor. The wide viewing area provided by the expansive glass front ensures that the mesmerizing flames are the focal point of any room, creating an inviting and cozy atmosphere.

The PALOMA-BZ-MOD incorporates advanced heating technologies that enhance efficiency and performance. Its powerful heating capacity can warm spaces effectively, allowing for comfortable living even in colder climates. The unit is designed to operate quietly, ensuring that the crackling flames are the only sound you hear. This makes it perfect for homes where relaxation and tranquility are priorities.

Another noteworthy aspect of the PALOMA-BZ-MOD is its customizable features. Homeowners can choose from a variety of decorative media options, including ceramic logs, glass beads, or pebbles, allowing for personalization that complements individual style preferences. The flame presentation is adjustable, giving users control over the height and intensity of the flames, thus enhancing both aesthetics and functionality.

The fireplace is equipped with innovative technologies for ease of use. The flexible installation options mean it can be placed in a variety of locations, whether it's a central feature in a living room or an elegant addition to a dining area. Additionally, a user-friendly remote control allows for convenient operation, enabling users to turn the fireplace on or off and adjust settings from across the room.

Safety is a priority with the PALOMA-BZ-MOD. It features an advanced safety shut-off system, ensuring peace of mind for homeowners. The continuous pilot light and electronic ignition system enhance reliability, providing instant warmth when needed.

In summary, the Heat & Glo LifeStyle PALOMA-BZ-MOD exemplifies a harmonious blend of modern design and advanced technology. With its captivating flames, customizable features, and efficient heating performance, it serves as both a functional heating solution and a stunning piece of decor, making it a popular choice for any contemporary home.