Heat & Glo LifeStyle PALOMA-BZ-MOD owner manual Left Rock Cluster

Page 36

REAR ROCK

RIGHT AND REAR CLUSTERS

MAKE CONTACT

CLUSTER

RIGHT ROCK

 

 

CLUSTER

 

 

Figure 4. Right and Rear Rock Clusters Make Contact

3.Place left rock cluster in firebox as shown in Figure 5. The left end of the cluster should touch the left wall of the firebox. Push cluster back until the rear and left rock clusters contact each other as shown in Figure 6. Ensure the rock clusters are not covering any burner ports.

WARNING! Risk of Explosion! Follow instructions for placing rock clusters. DO NOT allow rock cluster to cover burner ports. Improperly placed rock cluster will interfere with proper burner operation.

LEFT ROCK

CLUSTER

Figure 5. Placing Left Rock Cluster

 

LEFT AND REAR

 

LEFT ROCK

CLUSTERS MAKE

REAR ROCK

CONTACT

CLUSTER

CLUSTER

 

 

Figure 6. Left and Rear Rock Clusters Make Contact

4.Ember material is shipped with this kit. To place the ember material:

WARNING! Risk of Explosion! Follow ember placement instructions. DO NOT place embers directly over burner ports. Replace ember material annually. Improperly placed embers interfere with proper burner operation.

Embers CANNOT be placed directly over ports. Care should be taken not to cover the lighting trail of ports (from back to front).

Place dime-size pieces of embers in the areas highlighted in Figure 7. Care should be taken so that the ports are not covered. Failure to follow this procedure will likely cause lighting and sooting problems.

EMBERS

Figure 7. Ember Placement

36

Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD2189-900 Rev. i • 5/12

Image 36
Contents Models What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsDesign and Installation Considerations Getting StartedTools and Supplies Needed Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationClearances to Combustibles It is permissible to place the appliance on carpetTermination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting GuidelinesHorizontal Termination Adding Venting Components203 mm 178 mm 152 mm Fold Strap Vertical Termination Continue to assemble pipe sections until the height Secure the Vent Sections Twist-lock the vent cap and sealDisassemble Vent Sections Cathedral CeilingClass a Metal Chimney Existing Masonry Chimney Type aTo determine the length of flex needed, measure from Opening in Masonry Wall Installing Slim Line Trim Ring and Heat Shield Slim Line Wall ThimbleAssembling Slim Line Trim Ring and Heat Shield FIG. C Minimum Clearance Gas Information Fuel ConversionGas Pressures Gas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceIntelliFire Ignition System Wiring Wire Size Max. LengthLoss of Power and Battery Backup Usage Wall Switch Installation for Fan Optional Junction Box Wired to Wall SwitchAppliance Setup Remove Shipping MaterialsUnbolting Appliance from the Pallet Accessories Leveling and Lagging Down the ApplianceTop to Rear Vent Conversion Shutter Adjustment Installing the Vent RestrictorAir Shutter Settings Installing Rock Media and Ember Material InstallationLeft Rock Cluster Installation precautions Optional BlowerFAN Base Contacts FAN Bracket Recommended operating procedures 28 Blower Wiring DiagramRemote Controls Installing flame control solenoidRemote receiver Wiring the flame control solenoid REDFront Door Glass Assembly Replacement Inner Glass Door Assembly ReplacementOperating Instructions Before Lighting ApplianceControls Lighting Instructions IPI Final inspection byFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Ues to spark, and main Maintaining and Servicing Appliance Before servicingMaintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsHearth Pad Vent Components Diagram SLP Series Vent ComponentsVent Components List ComponentsRock Placement Service PartsPart number list on following Service Parts List StockedAt Depot #22 Bottom Plate Assembly NGK-DXV Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information

PALOMA-BZ-MOD specifications

The Heat & Glo LifeStyle PALOMA-BZ-MOD is an innovative and stylish gas fireplace designed to elevate the ambiance of any living space. This modern fireplace combines functionality, aesthetics, and advanced technology, making it an ideal choice for homeowners seeking both warmth and sophistication.

One of the standout features of the PALOMA-BZ-MOD is its contemporary design. With its clean lines and minimalist profile, this fireplace seamlessly integrates into various interior styles—from ultra-modern to classic decor. The wide viewing area provided by the expansive glass front ensures that the mesmerizing flames are the focal point of any room, creating an inviting and cozy atmosphere.

The PALOMA-BZ-MOD incorporates advanced heating technologies that enhance efficiency and performance. Its powerful heating capacity can warm spaces effectively, allowing for comfortable living even in colder climates. The unit is designed to operate quietly, ensuring that the crackling flames are the only sound you hear. This makes it perfect for homes where relaxation and tranquility are priorities.

Another noteworthy aspect of the PALOMA-BZ-MOD is its customizable features. Homeowners can choose from a variety of decorative media options, including ceramic logs, glass beads, or pebbles, allowing for personalization that complements individual style preferences. The flame presentation is adjustable, giving users control over the height and intensity of the flames, thus enhancing both aesthetics and functionality.

The fireplace is equipped with innovative technologies for ease of use. The flexible installation options mean it can be placed in a variety of locations, whether it's a central feature in a living room or an elegant addition to a dining area. Additionally, a user-friendly remote control allows for convenient operation, enabling users to turn the fireplace on or off and adjust settings from across the room.

Safety is a priority with the PALOMA-BZ-MOD. It features an advanced safety shut-off system, ensuring peace of mind for homeowners. The continuous pilot light and electronic ignition system enhance reliability, providing instant warmth when needed.

In summary, the Heat & Glo LifeStyle PALOMA-BZ-MOD exemplifies a harmonious blend of modern design and advanced technology. With its captivating flames, customizable features, and efficient heating performance, it serves as both a functional heating solution and a stunning piece of decor, making it a popular choice for any contemporary home.