Heat & Glo LifeStyle PALOMA-BZ-MOD owner manual Gas Connection, Check for GAS Leaks

Page 27

C. Gas Connection

Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI

223.1.Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

Note: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

WARNING

Gas Leak Risk

Support control when attaching pipe to prevent bending gas line.

Note: The gap between supply piping and gas access hole may be caulked with caulk with a minimum of 300ºF continuous exposure rating or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration.

Leak test all gas line joints and the gas control valve prior to and after starting the appliance.

Before making the gas connection, ensure that the appliance you are installing is designed for the type of gas being supplied. This information can be found on the ratings label under the appliance. If the appliance has been converted to propane (LP), the valve cover should have a label stating that the appliance has been converted to propane.

Connect the gas line at the 3/8 in. (10 mm) pipe connector on the valve at the back of appliance. We recommend connecting the appliance with an approved flex gas line. If flex gas lines are not approved in your area, you must connect a hard pipe to the gas hookup.

You must supply a manual shut-off valve in a visible location within 3 ft. (914 mm) of the appliance.

WARNING

Fire or Explosion Hazard

Gas buildup during line purge may ignite.

Purge should be performed by qualified technician.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flames.

A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.

Air only needs to be purged again if gas valve has been turned to the OFF position.

WARNING

CHECK FOR GAS LEAKS

Explosion Risk

Fire Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially-available, non-corrosive leak check solution. Be sure

to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

WARNING

Fire hazard.

Do NOT change the valve settings.

• This valve has been preset at the factory.

• Changing valve settings may result in fire hazard or bodily injury.

HIGH ALTITUDE INSTALLATIONS

Omni-Test Laboratories, Inc. listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.

Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD2189-900 Rev. i • 5/12

27

Image 27
Contents What to do if you smell gas ModelsHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsInspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesIt is permissible to place the appliance on carpet Clearances to CombustiblesVent Termination Minimum Clearances Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsVenting Guidelines How to Use the Vent GraphAdding Venting Components Horizontal Termination203 mm 178 mm 152 mm Fold Strap Vertical Termination Continue to assemble pipe sections until the height Twist-lock the vent cap and seal Secure the Vent SectionsCathedral Ceiling Disassemble Vent SectionsClass a Metal Chimney Type a Existing Masonry ChimneyTo determine the length of flex needed, measure from Opening in Masonry Wall Installing Slim Line Trim Ring and Heat Shield Slim Line Wall ThimbleAssembling Slim Line Trim Ring and Heat Shield FIG. C Minimum Clearance Gas Information Fuel ConversionGas Pressures Check for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance IntelliFire Ignition System WiringLoss of Power and Battery Backup Usage Junction Box Wired to Wall Switch Wall Switch Installation for Fan OptionalAppliance Setup Remove Shipping MaterialsUnbolting Appliance from the Pallet Leveling and Lagging Down the Appliance AccessoriesTop to Rear Vent Conversion Shutter Adjustment Installing the Vent RestrictorAir Shutter Settings Installation Installing Rock Media and Ember MaterialLeft Rock Cluster Optional Blower Installation precautionsFAN Base Contacts FAN Bracket 28 Blower Wiring Diagram Recommended operating proceduresRemote Controls Installing flame control solenoidRemote receiver RED Wiring the flame control solenoidInner Glass Door Assembly Replacement Front Door Glass Assembly ReplacementOperating Instructions Before Lighting ApplianceControls Final inspection by Lighting Instructions IPIFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Ues to spark, and main Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks Maintenance TasksAppliance Dimension Diagram Reference MaterialsHearth Pad SLP Series Vent Components Vent Components DiagramComponents Vent Components ListRock Placement Service PartsPart number list on following Service Parts List StockedAt Depot #22 Bottom Plate Assembly NGK-DXV Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information

PALOMA-BZ-MOD specifications

The Heat & Glo LifeStyle PALOMA-BZ-MOD is an innovative and stylish gas fireplace designed to elevate the ambiance of any living space. This modern fireplace combines functionality, aesthetics, and advanced technology, making it an ideal choice for homeowners seeking both warmth and sophistication.

One of the standout features of the PALOMA-BZ-MOD is its contemporary design. With its clean lines and minimalist profile, this fireplace seamlessly integrates into various interior styles—from ultra-modern to classic decor. The wide viewing area provided by the expansive glass front ensures that the mesmerizing flames are the focal point of any room, creating an inviting and cozy atmosphere.

The PALOMA-BZ-MOD incorporates advanced heating technologies that enhance efficiency and performance. Its powerful heating capacity can warm spaces effectively, allowing for comfortable living even in colder climates. The unit is designed to operate quietly, ensuring that the crackling flames are the only sound you hear. This makes it perfect for homes where relaxation and tranquility are priorities.

Another noteworthy aspect of the PALOMA-BZ-MOD is its customizable features. Homeowners can choose from a variety of decorative media options, including ceramic logs, glass beads, or pebbles, allowing for personalization that complements individual style preferences. The flame presentation is adjustable, giving users control over the height and intensity of the flames, thus enhancing both aesthetics and functionality.

The fireplace is equipped with innovative technologies for ease of use. The flexible installation options mean it can be placed in a variety of locations, whether it's a central feature in a living room or an elegant addition to a dining area. Additionally, a user-friendly remote control allows for convenient operation, enabling users to turn the fireplace on or off and adjust settings from across the room.

Safety is a priority with the PALOMA-BZ-MOD. It features an advanced safety shut-off system, ensuring peace of mind for homeowners. The continuous pilot light and electronic ignition system enhance reliability, providing instant warmth when needed.

In summary, the Heat & Glo LifeStyle PALOMA-BZ-MOD exemplifies a harmonious blend of modern design and advanced technology. With its captivating flames, customizable features, and efficient heating performance, it serves as both a functional heating solution and a stunning piece of decor, making it a popular choice for any contemporary home.