Heat & Glo LifeStyle PALOMA-BZ-MOD owner manual Existing Masonry Chimney, Type a

Page 21

4.Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8 in. (3 mm) diameter holes through the top adapter, and into the chimney top. Ensure that you are drilling into the metal on the chimney. Twist lock the high wind termination cap onto the top adapter (Figures 5.22 and 5.23).

Figure 5.22

HIGH WIND

TERMINATION CAP

SHEET METAL SCREWS

DRILL FOUR 1/8 IN. (3 MM)

DIAMETER HOLES

Figure 5.23

5.Pull the flex pipe down through the ceiling support box, until it protrudes approximately 3 in. (76 mm). Connect the flex pipe to the retro connector, and attach with sheet metal screws.

6.Push the flex pipe back up into the ceiling support box, center the retro connector, and attach it to the support box with sheet metal screws.

7.The connection between the appliance and the retro connector may be completed with sections of direct vent pipe.

L. Existing Masonry Chimney

Type A

CHIMNEY LINER

TERMINATION CAP PART

#923GK

3 IN. (76 MM) FLEX LINER

CO-AXIAL TO CO-LINEAR

CONNECTOR PART

#923GCL

PIPE LENGTH

(OPTIONAL)

SHOWING TWO 30 FT.

(9 M) SECTIONS OF

FLEX LINER

Type C - Up & Out Installation

*NOTE: In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor.

Figure 5.24

CAUTION

Ensure that existing chimney is functionally sound and clean.

Have inspection done by qualified chimney sweep or professional installer BEFORE converting to direct vent appliance.

1.Before cutting any holes, assemble the desired sections of direct vent pipe to determine the center of the masonry penetration.

2.Once the center point of the penetration has been determined, cut a 6 in. (152 mm) diameter hole in the masonry. If the hole is too large, the retro connector might not mount properly; if the hole is too small, the appliance might starve for intake air. If there is a frame wall in front of the masonry wall, cut and frame a 10 in. (254 mm) square opening in the wall (centered around the 6 in. (152 mm) masonry opening). If there is sheet rock only (no studs) in front of the masonry the 10 in. (254 mm) opening is still needed, but does not need to be framed. If the hole is framed a round support box/wall thimble is required. This allows the retro connector to mount directly on the masonry and provide the correct clearances to combustibles (Figure 5.25).

Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD2189-900 Rev. i • 5/12

21

Image 21
Contents What to do if you smell gas ModelsHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesIt is permissible to place the appliance on carpet Clearances to CombustiblesVent Termination Minimum Clearances Termination LocationsAlcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsVenting Guidelines How to Use the Vent GraphAdding Venting Components Horizontal Termination203 mm 178 mm 152 mm Fold Strap Vertical Termination Continue to assemble pipe sections until the height Twist-lock the vent cap and seal Secure the Vent SectionsCathedral Ceiling Disassemble Vent SectionsClass a Metal Chimney Type a Existing Masonry ChimneyTo determine the length of flex needed, measure from Opening in Masonry Wall Installing Slim Line Trim Ring and Heat Shield Slim Line Wall ThimbleAssembling Slim Line Trim Ring and Heat Shield FIG. C Minimum Clearance Gas Information Fuel ConversionGas Pressures Check for GAS Leaks Gas ConnectionConnecting to the Appliance Recommendation for WireIntelliFire Ignition System Wiring Wire Size Max. LengthLoss of Power and Battery Backup Usage Junction Box Wired to Wall Switch Wall Switch Installation for Fan OptionalAppliance Setup Remove Shipping MaterialsUnbolting Appliance from the Pallet Leveling and Lagging Down the Appliance AccessoriesTop to Rear Vent Conversion Shutter Adjustment Installing the Vent RestrictorAir Shutter Settings Installation Installing Rock Media and Ember MaterialLeft Rock Cluster Optional Blower Installation precautionsFAN Base Contacts FAN Bracket 28 Blower Wiring Diagram Recommended operating proceduresRemote Controls Installing flame control solenoidRemote receiver RED Wiring the flame control solenoidInner Glass Door Assembly Replacement Front Door Glass Assembly ReplacementOperating Instructions Before Lighting ApplianceControls Final inspection by Lighting Instructions IPIFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Ues to spark, and main Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks Maintenance TasksAppliance Dimension Diagram Reference MaterialsHearth Pad SLP Series Vent Components Vent Components DiagramComponents Vent Components ListRock Placement Service PartsPart number list on following Service Parts List StockedAt Depot #22 Bottom Plate Assembly NGK-DXV Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information

PALOMA-BZ-MOD specifications

The Heat & Glo LifeStyle PALOMA-BZ-MOD is an innovative and stylish gas fireplace designed to elevate the ambiance of any living space. This modern fireplace combines functionality, aesthetics, and advanced technology, making it an ideal choice for homeowners seeking both warmth and sophistication.

One of the standout features of the PALOMA-BZ-MOD is its contemporary design. With its clean lines and minimalist profile, this fireplace seamlessly integrates into various interior styles—from ultra-modern to classic decor. The wide viewing area provided by the expansive glass front ensures that the mesmerizing flames are the focal point of any room, creating an inviting and cozy atmosphere.

The PALOMA-BZ-MOD incorporates advanced heating technologies that enhance efficiency and performance. Its powerful heating capacity can warm spaces effectively, allowing for comfortable living even in colder climates. The unit is designed to operate quietly, ensuring that the crackling flames are the only sound you hear. This makes it perfect for homes where relaxation and tranquility are priorities.

Another noteworthy aspect of the PALOMA-BZ-MOD is its customizable features. Homeowners can choose from a variety of decorative media options, including ceramic logs, glass beads, or pebbles, allowing for personalization that complements individual style preferences. The flame presentation is adjustable, giving users control over the height and intensity of the flames, thus enhancing both aesthetics and functionality.

The fireplace is equipped with innovative technologies for ease of use. The flexible installation options mean it can be placed in a variety of locations, whether it's a central feature in a living room or an elegant addition to a dining area. Additionally, a user-friendly remote control allows for convenient operation, enabling users to turn the fireplace on or off and adjust settings from across the room.

Safety is a priority with the PALOMA-BZ-MOD. It features an advanced safety shut-off system, ensuring peace of mind for homeowners. The continuous pilot light and electronic ignition system enhance reliability, providing instant warmth when needed.

In summary, the Heat & Glo LifeStyle PALOMA-BZ-MOD exemplifies a harmonious blend of modern design and advanced technology. With its captivating flames, customizable features, and efficient heating performance, it serves as both a functional heating solution and a stunning piece of decor, making it a popular choice for any contemporary home.