Heat & Glo LifeStyle owner manual System Wiring, 6100PLUS Requirements

Page 15

C. System Wiring

6100PLUS Requirements

This gas appliance requires a 110VAC supply to the gas appliance junction box for operation. A wiring diagram is shown in Figure 8.1.

The 6100PLUS is equipped with an intermittent pilot control valve which operates on a 3 volt system. See ignition wiring diagram, Figure 8.1.

The 6100PLUS is supplied with a 3 volt AC transformer, which requires the installation of the supplied junction box. It is highly recommended that the junction box be installed at this time to avoid future reconstruction.

Note: Wire terminal latch can become damaged if excessive force is used when releasing wire. Please use caution in pressing retainer.

Figure 8.1 Intermittent Pilot Ignition Wiring Diagram

Note: The 6100PLUS must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code,

CSA C22.1.

Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05

15

Image 15
Contents What to do if you smell gas Models 6100PLUS Fresh Air FireplaceListing Label Information/Location Homeowner Reference InformationTable of Contents Non-Combustible Materials High Altitude InstallationsListing and Code Approvals Appliance CertificationInspect the Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededFraming and Clearances Select Appliance LocationFire Risk Fire Risk Odor Risk Construct the Appliance ChaseMantel Projections ClearancesTermination Locations Vent Termination Minimum ClearancesFire Risk Explosion Risk Fire Risk Fumes Risk Vent Information and DiagramsSecuring and Leveling the Appliance Appliance PreparationGas Leak Risk Gas InformationFuel Conversion Gas Connection Gas PressureFire Risk Explosion Risk Asphyxiation Risk Shock Risk Explosion Risk Recommendation for WireConnecting to the Appliance Electrical Information6100PLUS Requirements System WiringBetween R2 HRV200PLUS Control WiringAppliance Circuit Board Wiring Electric Embers On/Off Wall SwitchOptional Accessories Requirements Flame On/OffJunction Box Detail Junction Box InstallationFacing Material FinishingRemove the Shipping Materials Appliance SetupClean the Appliance Lava Rock, Rockwool, Silica Rock PlacementPlacing the Silica Rock Techno Sil Placing the Rock WoolPlace the Top Log Grate and Log AssemblyPlace the Grate Place the Right Front LogFire Risk Burn Risk Appliance ModeOperating Instructions Sequence of OperationHRV200PLUS Defrost Mode Lighting the Appliance Initial Break-in Procedure Fire Risk High TemperaturesAfter the Appliance is Lit Troubleshooting Guide TroubleshootingMaintaining and Servicing the Appliance Annual MaintenanceEmber Bed Bulb Replacement Cleaning the Burner and Control CompartmentThis page intentionally left blank Reference Materials Appliance Dimension Diagram6100PLUS Service Parts ListLog Set Refractory Assembly, Traditional6100PLUS 6100PLUS-LP Description of Part 6100PLUSSpvn Spwd Spwv Remote Control Wall SwitchOptional Components SpflOptional Components 6100PLUS 6100PLUS-LP Qty Arched Cabinet Doors Essence SeriesArched Cabinet Doors Prism Series This page intentionally left blank Limited Lifetime Warranty Contact Information