TABLE 2. TERMINAL REFERENCE
LABEL | NEW THERMOSTAT |
| OLD THERMOSTAT | ||
TERMINAL |
|
| TERMINAL | ||
NUMBER | DESIGNATION | FUNCTION | DESIGNATION | ||
(1) | G | Fan Output |
|
|
|
(2) | C | Transformer 24 VAC Common |
|
|
|
(3) | L | (this terminal not used) |
|
|
|
(4) | R | Transformer 24 VAC Hot |
|
|
|
(5) | O | Changeover Output (Cooling) |
|
|
|
(6) | B | Changeover Output (Heating) |
|
|
|
(7) | E1 | Emergency Heat Relay (cycles on |
|
|
|
|
| 1st stage in Emergency Mode) |
|
|
|
(8) | E2 | Emergency Heat Relay (continually |
|
|
|
|
| energized in Emergency Mode) |
|
|
|
(9) | Y1 | Stage 1 Cool |
|
|
|
(10) | Y2 | (this terminal not used) |
|
|
|
(11) | W1 | Stage 1 Heat (Compressor) |
|
|
|
(12) | W2 | Stage 2 Heat (Auxiliary) |
|
|
|
(13) | W3 | (this terminal not used) |
|
|
|
|
|
|
|
|
|
10