White Rodgers 1F92W-51 manual Check Thermostat Operation, FAN Operation, Heating System Operation

Page 19

CHECK THERMOSTAT OPERATION

When checking thermostat, option switch #4 for automatic changeover must be in the OFF position. This will allow temporary setting of heat set points above cool settings. After system checkout, reset option switch to ON position if automatic changeover is desired (see SET OPTION SWITCHES).

FAN OPERATION

1.Turn on power to the system. If the auxiliary heat source has a standing pilot, be sure to light it.

HEATING SYSTEM OPERATION

1. Press

SYSTEM

until HEAT is displayed. (It should

HEAT-OFF-COOL-AUTO

already be displayed.)

2.Press to adjust thermostat to 99°F. All stages of the heating system should come on within approximately five minutes. However, if the PUMP LED is flashing, the compressor lock- out feature is operating (see Lockout Bypass Option to temporarily override the compressor lockout feature during testing).

2. Press

FAN

ON – AUTO

until FAN

NOTE

is displayed. The

3. Press

SYSTEM

until EMER is displayed. Repeat

HEAT-OFF-COOL-AUTO

step 2.

blower should begin to operate.

3. Press

FAN

until FAN

is displayed. The

ON – AUTO

blower should stop operating within approxi- mately one minute.

4.To program the thermostat, see PROGRAM-

MING YOUR THERMOSTAT.

19

Image 19
Contents 1F92W-51 About Your New Thermostat Programming Your THERMOSTAT’S Specifications Installing Your ThermostatYour NEW THERMOSTAT’S Operating Your ThermostatYour NEW THERMOSTAT’S Features Precautions Staging Data THERMOSTAT’S SpecificationsAccessories Electrical Data Thermal DataNEW Installation Installing Your ThermostatRoute Wires to Location Routing thermostat wires Wall Replacement InstallationWire Identification Labels Remove OLD ThermostatPage Attach Subbase to Wall Subbase Typical wiring diagram for single transformer systems Depending on System Require Heat Pump System USE Attach Thermostat to SubbaseTo Turn Thermostat OFF be SET Option Switches System ConfigurationTwo Compressor Split System Switch #1 on Switch #2 on Ming Your Thermostat Check Thermostat OperationFAN Operation Heating System OperationCooling System Operation Compressor Short Term Cycle Protection Lockout Bypass OptionPress Use System to turn the thermostat OFF Operating Your ThermostatBack of the Thermostat Body Parts of the ThermostatTo turn thermostat OFF before Removing thermostat from the wall to re- place the batteryAting Features UseSystem Time SET View Hold Used with Thermostat Buttons and LightsSystem Time SET View Hold Operating Features Automatic Changeover on Automatic Changeover OFF TWO Hour Temperature OverrideConvertibility Press Time To adjust Heat anticipation, pressTo increase the cycle time. If the heat Cool or Heat LOW Battery Indicator The word BATCompressor Short Cycle Protec CoolUntil FAN Planning for Your Needs Programming Your ThermostatYour Home Your needs, simply press Factory preset programProgramming. be Sure to Press Entering Your ProgramTurn Thermostat OFF Before REATTACH- ING to Subbase Weekday 5 DAY Weekend 2 DAY Heating/Cooling Schedule PlanMOR Heat SampleEnter Heating Program Set Current Time and DayPress and hold either Until youWant to stop programming at any time, simply press Fore Reattaching to Subbase Enter Cooling ProgramCheck Your Programming Gramming Your Thermostat Questions and AnswersUntil you return to the point where you How can I permanently change a part of my program?What can cause the thermostat display to freeze or go blank? Why can’t I program the thermostat in the Auto mode?Mostat ING Your ThermostatErating Your Thermostat Why is the system turning on and off so frequently seldom? Maintains programming, press System until Page Page Part No -5414A