ATTACH SUBBASE TO WALL
1.Remove the packing material from the thermo- stat. Place the fingers of one hand on the center top and bottom portion of the thermostat. Grasp the subbase in the other hand on the top and bottom center, and gently pull straight out (see fig. 2). The thermostat has pin and socket con- nectors. Forcing or prying on the thermostat will cause damage to the unit.
2.Connect wires beneath terminal screws on sub- base using wiring schematic for your particular application (see figs. 3 through 6).
3.Place subbase over hole in wall and mark mounting hole locations on wall using subbase as a template.
4.Move subbase out of the way. Drill mounting holes.
5.Fasten subbase loosely to wall, as shown in fig. 3, using two mounting screws. Place a level against bottom of subbase, adjust until level, and
then tighten screws. (Leveling is for appearance only and will not affect thermostat operation.) If you are using existing mounting holes, or if holes drilled are too large and do not allow you to tighten subbase snugly, use plastic expansion plugs to secure subbase.
6.Push excess wire into wall and plug hole with a
(Instructions continue on page 16).
11