Desa (V)K42P Installing Gas Piping to Fireplace Location, Blower Wiring Diagram

Page 16

Fireplace Installation

Continued

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and thermal switch, and that the screw for the thermodisc bracket and green ground wire is tight.

5.Mount the speed control box against the mounting plate provided in the lower fireplace cavity by placing the plastic control shaft forward through the round hole (see Figure 26, page 15).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against mounting plate. Place control knob provided on shaft (see Figure 26, page 15).

7.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Also double check all wire leads and make sure wire routing is not pinched or in a precarious position. Correct accordingly.

8.Turn on power to duplex outlet if previously turned off per the warning in column 2, page 14.

9.Plug in blower power cord to duplex outlet.

10.The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be adjusted by rotating the control knob. To turn off, turn knob fully counterclock- wise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically.

11.Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27, page 15).

Blower Wiring Diagram

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause im- proper and dangerous operation. Verify proper opera- tion after servicing.

 

 

 

Variable

Fan Switch

 

 

Fan Switch

 

 

 

 

(N.O.)

 

 

Off

1

Black

 

 

 

2

110/115

On

 

Blue

 

 

 

V.A.C. Black

 

Blower

 

 

 

 

 

 

White

 

Motor

Green

Figure 29 - Blower Wiring Diagram for Thermostat-Controlled

Models

Installing Gas Piping to Fireplace Location

WARNING:Aqualified service person must connect fireplace to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect fireplace directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the fireplace and pro- pane/LP supply.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

• external regulator (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

• approved flexible gas line with gas connector (if allowed by local codes)

*ACSAdesign-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your retailer. For propane/LP connection only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 30. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

External

Propane/LP

Regulator

Supply Tank

Vent

Pointing

Down

Figure 30 - External Regulator with Vent Pointing Down

(Propane/LP Only)

16

www.desatech.com

111921-01E

Image 16
Contents For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product FeaturesLocal Codes Location and space requirements Pre-Installation PreparationClearances Framing Clearances for Installation Against an Exterior Wall Framing and finishingLocation of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationVent Pipe Connections Vent pipe before connecting horizontal run to vent cap see Horizontal Termination Configurations Ground Floor InstallationSnorkel Termination Installation Venting with Two 90 ElbowsFlat Ceiling Installation Offset with Wall Strap and 45 ElbowsVertical Termination Configurations Vertical VentingFireplace Installation High Altitude InstallationParts lists for venting kits and components Installing optional blower accessoriesModel BKT Installation Attaching Speed Control to FireboxBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver Installing Brick liner Models BL42DASA and BL42DHASA Cleaning Glass DoorRemoving/Replacing Glass Door Removing Louver PanelsInstalling logs, lava rock Glowing embers Installing Brick PanelsOperating Fireplace For your safety read Before lightingLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOpTIONAL Hand-Held Remote OperationThermostat Series Model HRC200 Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Cleaning Maintenance Pilot assemblyInspecting Burners Burner Flame PatternTroubleshooting To clean pilot. This can damage pilot unitPilot and burners LogsTroubleshooting Gas leak. See Warning statement AboveReplacement Parts Service HintsTechnical Service SpecificationsAccessories Illustrated Parts Breakdown Models VK42N, VK42NH, VK42P and VK42PHParts List Burner Assembly for Models VK42N, VK42NH, VK42P and VK42PH KEY NO. Part NO. Description 111921-01E 111921-01E Warranty Information Keep this Warrant

(V)K42P specifications

Desa (V)K42P is an advanced model designed to cater to the demands of modern consumers looking for efficient performance, sustainability, and innovative features. This product stands out in the market due to its unique combination of technology, design, and functionality, making it suitable for both professional and personal use.

One of the main features of the Desa (V)K42P is its cutting-edge energy efficiency. It utilizes a high-performance motor that optimizes energy consumption, leading to lower utility bills while contributing to environmental sustainability. This technology ensures that users can operate the device for extended periods without worrying about excessive energy costs.

Another significant characteristic of the Desa (V)K42P is its user-friendly interface. Designed with the end-user in mind, it includes intuitive controls and a bright digital display that simplifies operation. The easy navigation allows users of all technical expertise to quickly master its functionalities, enhancing the overall user experience.

The Desa (V)K42P is also equipped with advanced connectivity features. With integrated Wi-Fi and Bluetooth capabilities, users can connect the device to their smartphones or tablets, allowing for remote access and control. This smart technology enables users to monitor performance, schedule operations, and receive updates directly from their devices, adding a layer of convenience to its usage.

In terms of durability, the Desa (V)K42P is constructed with high-quality materials designed to withstand wear and tear. Its robust build ensures longevity, making it a reliable investment for users. Furthermore, it features an easy-to-clean design, which enhances its practicality in daily use.

The product also incorporates safety features that protect users during operation. These include automatic shut-off mechanisms and thermal protection systems, which help prevent overheating and potential hazards.

In conclusion, the Desa (V)K42P is a versatile and efficient product that meets the needs of today's consumers. Its energy-efficient design, user-friendly interface, smart connectivity, durability, and safety features make it a standout choice in its category. Whether for home or professional use, the Desa (V)K42P offers a comprehensive solution that prioritizes performance without compromising on convenience or safety.