Fireplace Installation

Continued

3.Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 34 or 35). Apply noncor- rosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Propane/LP Equipment

Supply Tank Shutoff

Valve

Gas Valve

Figure 34 - Checking Gas Joints for Propane/LP Gas

Fireplace

Equipment

Shutoff

Valve

Gas

Meter

Gas Valve

Figure 35 - Checking Gas Joints for Natural Gas Fireplace

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 33, page 17).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas valve (see Figure 34 or 35). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fireplace, page 21). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 22).

Installing Optional Wall Mount

Switch - GWMS2

1.Connect one terminal of 25 ft. wire for wall switch to the TPTH terminal on valve. Connect remaining wire terminal to TH terminal on valve. Make sure wire terminals are in positions on unit as pictured in Figure 36. If wires are not connected as shown, switch will not work.

2.Route 25 ft. wire through openings provided on sides of burner system to a convenient location to mount switch.

3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.

4.Install wall switch and cover in wall.

Figure 36 - Connecting Wall Switch to Control Cover

Installing optional Wireless Hand- Held Remote Control - HRC100 AND HRC200 SERIES

NOTICE: Use only alkaline batteries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 37).

4.Attach the terminal wires to the battery.

5.Connect wires from receiver to TH and TPTH to control valve (see Figure 38).

6.Replace the switch bracket.

Receiver

 

9-Volt

Terminal

Alkaline

Battery

Wires

 

Battery Clip

Figure 37 - Attaching Alkaline Battery to Receiver

To Optional

Remote

Accessory

Figure 38 - Control Valve Terminals

18

www.desatech.com

111921-01E

Image 18
Contents For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Features Product IdentificationLocal Codes Pre-Installation Preparation Location and space requirementsClearances Framing Clearances for Installation Against an Exterior Wall Framing and finishingLocation of Termination Cap Termination CAP AIR Supply Inlet GAS MeterInstallation Planning Venting Installation InstructionsInstallation Precautions Horizontal Termination InstallationVent Pipe Connections Vent pipe before connecting horizontal run to vent cap see Horizontal Termination Configurations Ground Floor InstallationSnorkel Termination Installation Venting with Two 90 ElbowsFlat Ceiling Installation Offset with Wall Strap and 45 ElbowsVertical Termination Configurations Vertical VentingParts lists for venting kits and components Fireplace InstallationHigh Altitude Installation Installing optional blower accessoriesModel BKT Installation Attaching Speed Control to FireboxInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Pressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsInstalling Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver Removing/Replacing Glass Door Installing Brick liner Models BL42DASA and BL42DHASACleaning Glass Door Removing Louver PanelsInstalling logs, lava rock Glowing embers Installing Brick PanelsFor your safety read Before lighting Operating FireplaceLighting Instructions OpTIONAL Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationOperating optional blower accessory Thermostat Series Model HRC200Operating optional GWMT1 Wall Mounted Thermostat Inspecting Burners Cleaning MaintenancePilot assembly Burner Flame PatternPilot and burners TroubleshootingTo clean pilot. This can damage pilot unit LogsTroubleshooting Gas leak. See Warning statement AboveTechnical Service Replacement PartsService Hints SpecificationsAccessories Illustrated Parts Breakdown Models VK42N, VK42NH, VK42P and VK42PHParts List Burner Assembly for Models VK42N, VK42NH, VK42P and VK42PH KEY NO. Part NO. Description 111921-01E 111921-01E Warranty Information Keep this Warrant

(V)K42P specifications

Desa (V)K42P is an advanced model designed to cater to the demands of modern consumers looking for efficient performance, sustainability, and innovative features. This product stands out in the market due to its unique combination of technology, design, and functionality, making it suitable for both professional and personal use.

One of the main features of the Desa (V)K42P is its cutting-edge energy efficiency. It utilizes a high-performance motor that optimizes energy consumption, leading to lower utility bills while contributing to environmental sustainability. This technology ensures that users can operate the device for extended periods without worrying about excessive energy costs.

Another significant characteristic of the Desa (V)K42P is its user-friendly interface. Designed with the end-user in mind, it includes intuitive controls and a bright digital display that simplifies operation. The easy navigation allows users of all technical expertise to quickly master its functionalities, enhancing the overall user experience.

The Desa (V)K42P is also equipped with advanced connectivity features. With integrated Wi-Fi and Bluetooth capabilities, users can connect the device to their smartphones or tablets, allowing for remote access and control. This smart technology enables users to monitor performance, schedule operations, and receive updates directly from their devices, adding a layer of convenience to its usage.

In terms of durability, the Desa (V)K42P is constructed with high-quality materials designed to withstand wear and tear. Its robust build ensures longevity, making it a reliable investment for users. Furthermore, it features an easy-to-clean design, which enhances its practicality in daily use.

The product also incorporates safety features that protect users during operation. These include automatic shut-off mechanisms and thermal protection systems, which help prevent overheating and potential hazards.

In conclusion, the Desa (V)K42P is a versatile and efficient product that meets the needs of today's consumers. Its energy-efficient design, user-friendly interface, smart connectivity, durability, and safety features make it a standout choice in its category. Whether for home or professional use, the Desa (V)K42P offers a comprehensive solution that prioritizes performance without compromising on convenience or safety.