Desa (V)K42P Removing/Replacing Glass Door, Installing Brick liner Models BL42DASA and BL42DHASA

Page 19

Fireplace Installation

Continued

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

Battery Cover

Remote Control Unit

 

Terminal

Wires

9-Volt

Battery

Housing

Battery

 

Figure 39 - Installing Alkaline Battery in Hand-Held Remote

Control Unit

Removing/Replacing Glass Door

CAUTION: Do not operate this fireplace with a bro- ken glass door panel or without the glass door panel securely in place. For replacement part information see Replacement Parts, page 28.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before removing glass door or louvers.

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 40). Repeat for bottom spring latches and pull the louvers outward. To install or replace items removed, simply reverse the procedures above.

Spring Latch

Louver Panel

Figure 40 - Removing Louver Panel

Removing Glass Door

If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.

1.Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the firebox. Set assembly aside.

2.Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 41).

3.While holding glass door to prevent it from falling and causing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 41).

4.Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket.

5.Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 41).

6.Replace screen/rod assembly by reversing step 1.

7.Replace louvers by reversing procedure under Removing Lou- ver Panels.

Unlock Lock

Latch

Hinge

Screw

Glass

Frame

Assembly

Figure 41 - Removing/Replacing Glass Door

Cleaning Glass Door

See Cleaning and Maintenance on page 24.

Installing Brick liner Models BL42DA(SA) and BL42DHA(SA)

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before installing brick liner.

You may purchase brick liner from your local retailer or see Ac- cessories, page 29.

CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Excessive force will break brick panels.

1.Remove top and bottom louvers to allow access to door latches.

2.Unlock door latches and open glass door. See steps 1 and 2 of

Removing/Replacing Glass Door.

111921-01E

www.desatech.com

19

Image 19
Contents What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsProduct Identification Product FeaturesLocal Codes Location and space requirements Pre-Installation PreparationClearances Framing and finishing Framing Clearances for Installation Against an Exterior WallTermination CAP AIR Supply Inlet GAS Meter Location of Termination CapHorizontal Termination Installation Venting Installation InstructionsInstallation Precautions Installation PlanningVent Pipe Connections Vent pipe before connecting horizontal run to vent cap see Ground Floor Installation Horizontal Termination ConfigurationsVenting with Two 90 Elbows Snorkel Termination InstallationOffset with Wall Strap and 45 Elbows Flat Ceiling InstallationVertical Venting Vertical Termination ConfigurationsInstalling optional blower accessories Fireplace InstallationHigh Altitude Installation Parts lists for venting kits and componentsAttaching Speed Control to Firebox Model BKT InstallationBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver Removing Louver Panels Installing Brick liner Models BL42DASA and BL42DHASACleaning Glass Door Removing/Replacing Glass DoorInstalling Brick Panels Installing logs, lava rock Glowing embersOperating Fireplace For your safety read Before lightingLighting Instructions Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance OpTIONAL Hand-HeldThermostat Series Model HRC200 Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Burner Flame Pattern Cleaning MaintenancePilot assembly Inspecting BurnersLogs TroubleshootingTo clean pilot. This can damage pilot unit Pilot and burnersTroubleshooting Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceAccessories Models VK42N, VK42NH, VK42P and VK42PH Illustrated Parts BreakdownParts List Burner Assembly for Models VK42N, VK42NH, VK42P and VK42PH KEY NO. Part NO. Description 111921-01E 111921-01E Keep this Warrant Warranty Information

(V)K42P specifications

Desa (V)K42P is an advanced model designed to cater to the demands of modern consumers looking for efficient performance, sustainability, and innovative features. This product stands out in the market due to its unique combination of technology, design, and functionality, making it suitable for both professional and personal use.

One of the main features of the Desa (V)K42P is its cutting-edge energy efficiency. It utilizes a high-performance motor that optimizes energy consumption, leading to lower utility bills while contributing to environmental sustainability. This technology ensures that users can operate the device for extended periods without worrying about excessive energy costs.

Another significant characteristic of the Desa (V)K42P is its user-friendly interface. Designed with the end-user in mind, it includes intuitive controls and a bright digital display that simplifies operation. The easy navigation allows users of all technical expertise to quickly master its functionalities, enhancing the overall user experience.

The Desa (V)K42P is also equipped with advanced connectivity features. With integrated Wi-Fi and Bluetooth capabilities, users can connect the device to their smartphones or tablets, allowing for remote access and control. This smart technology enables users to monitor performance, schedule operations, and receive updates directly from their devices, adding a layer of convenience to its usage.

In terms of durability, the Desa (V)K42P is constructed with high-quality materials designed to withstand wear and tear. Its robust build ensures longevity, making it a reliable investment for users. Furthermore, it features an easy-to-clean design, which enhances its practicality in daily use.

The product also incorporates safety features that protect users during operation. These include automatic shut-off mechanisms and thermal protection systems, which help prevent overheating and potential hazards.

In conclusion, the Desa (V)K42P is a versatile and efficient product that meets the needs of today's consumers. Its energy-efficient design, user-friendly interface, smart connectivity, durability, and safety features make it a standout choice in its category. Whether for home or professional use, the Desa (V)K42P offers a comprehensive solution that prioritizes performance without compromising on convenience or safety.