Desa (V)K42P Inspecting Burners, Cleaning Maintenance, Pilot assembly, Burner Flame Pattern

Page 24

Inspecting Burners

Check pilot flame pattern and burner flame patterns often.

pilot assembly

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure 53. The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.

If you pilot assembly does not meet these requirements:

turn fireplace off (see To Turn Off Gas to Appliance, page 22)

see Troubleshooting, page 25

Thermopile

3/8" to 1/2"

Pilot Burner

1/8"

Thermocouple

Piezo

Ignitor

Figure 53 - Pilot Assembly

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on instal- lation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after instal- lation to ensure proper installation and performance.

Figure 54 shows a typical flame pattern for these models. If burner flame pattern differs from that described:

turn fireplace off (see To Turn Off Gas to Appliance, page 22)

see Troubleshooting, page 25

Figure 54 - Typical Flame Pattern

Cleaning and

Maintenance

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION:You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not op- erate fireplace with the glass door removed, cracked, or broken.

WARNING: Do not use abrasive cleaners as this may damage glass. Use a nonabrasive household glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint cur- ing. The glass should be cleaned several times with a non-ammonia, nonabrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circum- stances present. Refer to Removing/Replacing Glass Door, page 19, when removing glass door for cleaning.

WARNING: Only parts supplied by the manufacturer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 28). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

If glass has been broken, carefully remove glass door (see Remov- ing/Replacing Glass Door, page 19). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 28 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 19, for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass door removed, cracked, or broken.

24

www.desatech.com

111921-01E

Image 24
Contents For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Features Product IdentificationLocal Codes Pre-Installation Preparation Location and space requirementsClearances Framing Clearances for Installation Against an Exterior Wall Framing and finishingLocation of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationVent Pipe Connections Vent pipe before connecting horizontal run to vent cap see Horizontal Termination Configurations Ground Floor InstallationSnorkel Termination Installation Venting with Two 90 ElbowsFlat Ceiling Installation Offset with Wall Strap and 45 ElbowsVertical Termination Configurations Vertical VentingFireplace Installation High Altitude InstallationParts lists for venting kits and components Installing optional blower accessoriesModel BKT Installation Attaching Speed Control to FireboxInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver Installing Brick liner Models BL42DASA and BL42DHASA Cleaning Glass DoorRemoving/Replacing Glass Door Removing Louver PanelsInstalling logs, lava rock Glowing embers Installing Brick PanelsFor your safety read Before lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOpTIONAL Hand-Held Remote OperationOperating optional blower accessory Thermostat Series Model HRC200Operating optional GWMT1 Wall Mounted Thermostat Cleaning Maintenance Pilot assemblyInspecting Burners Burner Flame PatternTroubleshooting To clean pilot. This can damage pilot unitPilot and burners LogsTroubleshooting Gas leak. See Warning statement AboveReplacement Parts Service HintsTechnical Service SpecificationsAccessories Illustrated Parts Breakdown Models VK42N, VK42NH, VK42P and VK42PHParts List Burner Assembly for Models VK42N, VK42NH, VK42P and VK42PH KEY NO. Part NO. Description 111921-01E 111921-01E Warranty Information Keep this Warrant

(V)K42P specifications

Desa (V)K42P is an advanced model designed to cater to the demands of modern consumers looking for efficient performance, sustainability, and innovative features. This product stands out in the market due to its unique combination of technology, design, and functionality, making it suitable for both professional and personal use.

One of the main features of the Desa (V)K42P is its cutting-edge energy efficiency. It utilizes a high-performance motor that optimizes energy consumption, leading to lower utility bills while contributing to environmental sustainability. This technology ensures that users can operate the device for extended periods without worrying about excessive energy costs.

Another significant characteristic of the Desa (V)K42P is its user-friendly interface. Designed with the end-user in mind, it includes intuitive controls and a bright digital display that simplifies operation. The easy navigation allows users of all technical expertise to quickly master its functionalities, enhancing the overall user experience.

The Desa (V)K42P is also equipped with advanced connectivity features. With integrated Wi-Fi and Bluetooth capabilities, users can connect the device to their smartphones or tablets, allowing for remote access and control. This smart technology enables users to monitor performance, schedule operations, and receive updates directly from their devices, adding a layer of convenience to its usage.

In terms of durability, the Desa (V)K42P is constructed with high-quality materials designed to withstand wear and tear. Its robust build ensures longevity, making it a reliable investment for users. Furthermore, it features an easy-to-clean design, which enhances its practicality in daily use.

The product also incorporates safety features that protect users during operation. These include automatic shut-off mechanisms and thermal protection systems, which help prevent overheating and potential hazards.

In conclusion, the Desa (V)K42P is a versatile and efficient product that meets the needs of today's consumers. Its energy-efficient design, user-friendly interface, smart connectivity, durability, and safety features make it a standout choice in its category. Whether for home or professional use, the Desa (V)K42P offers a comprehensive solution that prioritizes performance without compromising on convenience or safety.