Location and space requirements

Determine the safest and most efficient location for your DESA direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap.

When deciding the location of your fireplace, follow these rules:

Do not connect this fireplace venting to a chimney flue serving a separate solid-fuel burning fireplace or appliance.

Due to high temperatures, do not locate this fireplace in high traf- fic areas, windy or drafty areas, or near furniture or draperies.

Proper clearances must be maintained.

If your fireplace is to be installed directly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

Your fireplace is designed to be used in zero clearance instal- lations. Wall or framing material can be placed directly against any exterior surface on the back, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 5.

If you plan on installing a television or entertainment center re- cessed above your fireplace, it is recommended that you maintain a minimum 18" above top of louver opening.

When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 6.

If recessing into a wall, you can avoid extra framing by position- ing your fireplace against an already existing framing member.

Do not recess termination cap into a wall or siding.

You may paint the termination cap with 450º F (232º C) heat- resistant paint to coordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.

Flush with a wall

Corner installation

Through exterior wall enclosed in a chase

Figure 2 - Common Fireplace Locations

361/4"

231/4"

48"

Figure 3 - Fireplace Bottom Dimensions

Clearances

Minimum clearances to combustibles for the fireplace are as follows:

Back, and sides

0"/mm

Perpendicular walls

6" (15.2 cm)

Floor

0"/mm

Ceiling to louver opening

42" (106.7 cm)

Front

36" (91.4 cm)

Top

0"/mm

Vent

(See venting instructions for

 

specific venting clearances.)

Combustible material with a maximum thickness of 5/8" may be flush with the top front of fireplace .

NOTICE: This fireplace is intended for use as supple- mental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using fireplace. This will help circulate the heat throughout the house.

www.desatech.com

111921-01E

Image 4
Contents For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product FeaturesLocal Codes Location and space requirements Pre-Installation PreparationClearances Framing Clearances for Installation Against an Exterior Wall Framing and finishingLocation of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationVent Pipe Connections Vent pipe before connecting horizontal run to vent cap see Horizontal Termination Configurations Ground Floor InstallationSnorkel Termination Installation Venting with Two 90 ElbowsFlat Ceiling Installation Offset with Wall Strap and 45 ElbowsVertical Termination Configurations Vertical VentingFireplace Installation High Altitude InstallationParts lists for venting kits and components Installing optional blower accessoriesModel BKT Installation Attaching Speed Control to FireboxBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver Installing Brick liner Models BL42DASA and BL42DHASA Cleaning Glass DoorRemoving/Replacing Glass Door Removing Louver PanelsInstalling logs, lava rock Glowing embers Installing Brick PanelsOperating Fireplace For your safety read Before lightingLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOpTIONAL Hand-Held Remote OperationThermostat Series Model HRC200 Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Cleaning Maintenance Pilot assemblyInspecting Burners Burner Flame PatternTroubleshooting To clean pilot. This can damage pilot unitPilot and burners LogsTroubleshooting Gas leak. See Warning statement AboveReplacement Parts Service HintsTechnical Service SpecificationsAccessories Illustrated Parts Breakdown Models VK42N, VK42NH, VK42P and VK42PHParts List Burner Assembly for Models VK42N, VK42NH, VK42P and VK42PH KEY NO. Part NO. Description 111921-01E 111921-01E Warranty Information Keep this Warrant

(V)K42P specifications

Desa (V)K42P is an advanced model designed to cater to the demands of modern consumers looking for efficient performance, sustainability, and innovative features. This product stands out in the market due to its unique combination of technology, design, and functionality, making it suitable for both professional and personal use.

One of the main features of the Desa (V)K42P is its cutting-edge energy efficiency. It utilizes a high-performance motor that optimizes energy consumption, leading to lower utility bills while contributing to environmental sustainability. This technology ensures that users can operate the device for extended periods without worrying about excessive energy costs.

Another significant characteristic of the Desa (V)K42P is its user-friendly interface. Designed with the end-user in mind, it includes intuitive controls and a bright digital display that simplifies operation. The easy navigation allows users of all technical expertise to quickly master its functionalities, enhancing the overall user experience.

The Desa (V)K42P is also equipped with advanced connectivity features. With integrated Wi-Fi and Bluetooth capabilities, users can connect the device to their smartphones or tablets, allowing for remote access and control. This smart technology enables users to monitor performance, schedule operations, and receive updates directly from their devices, adding a layer of convenience to its usage.

In terms of durability, the Desa (V)K42P is constructed with high-quality materials designed to withstand wear and tear. Its robust build ensures longevity, making it a reliable investment for users. Furthermore, it features an easy-to-clean design, which enhances its practicality in daily use.

The product also incorporates safety features that protect users during operation. These include automatic shut-off mechanisms and thermal protection systems, which help prevent overheating and potential hazards.

In conclusion, the Desa (V)K42P is a versatile and efficient product that meets the needs of today's consumers. Its energy-efficient design, user-friendly interface, smart connectivity, durability, and safety features make it a standout choice in its category. Whether for home or professional use, the Desa (V)K42P offers a comprehensive solution that prioritizes performance without compromising on convenience or safety.