Desa CGEFP33PR Installing Variable Speed Blower Accessory, Ing from inside mantel see Figure

Page 11

INSTALLATION

Relocating Wall Switch (Cont.) Installing Variable Speed Blower Accessory

11

INSTALLATION

Continued

16.Position switch/plate assembly vertically over wall openings with decal lettering upright (see Figure 13).

17.Insert mounting screws, removed in step 2 of Relocating Wall Switch on pages 9 and 10, through holes in wall plate and into wall anchors.

18.Tighten screws until wall plate is firmly attached to wall. Do not overtighten.

Opening in

Wall or

Mantel Wall

Wall Plate/

Switch

Screws

Figure 13 - Securing Wall Switch

Mounting Wall Switch to Side of Mantel

7.

Create three openings in the mantel wall according to Tem-

 

plate 2, page 45. This is best done by making a pattern to work

 

with on the mantel. Carefully cut page 45/46 from manual and

 

tape paper template vertically onto mantel wall at preferred

 

location. Pierce the paper at the centers of the 2 holes with a

 

nail or sharp pencil, leaving a mark on the wall. Do the same

 

at centers of the four circles near the corners of the rectangle.

8.

Remove paper template from mantel wall.

9.

Drill 1/8" pilot holes at each mark for top and bottom screw

 

holes. Drill 3/8" holes at each mark for centers of four circles

 

near corners of rectangle.

10.

Using a straight edge and pencil, connect the outer edges of the 4

 

holes for the rectangle (see Figure 10, page 10). This will give

 

you cutting lines for the rectangle you will cut in the mantel wall.

11.

Using a keyhole saw, hack saw blade, drill, file, or other suit-

 

able tool, carefully cut out the rectangular opening. Note: The

 

corners of the rectangle may be round. IMPORTANT: Do not

13.Position switch/plate assembly vertically over opening with decal lettering upright. Make sure wires freely pass through wall without binding. Align holes in wall plate with 1/8" pilot holes in mantel wall.

14.Drive mounting screws, removed in step 2 of Relocating Wall Switch on pages 9 and 10, through wall plate holes and into pilot holes in mantel wall.

15.Tighten screws until wall plate is firmly attached to mantel. Do not overtighten.

INSTALLING VARIABLE SPEED BLOWER ACCESSORY

NOTICE: Shut off gas supply and disconnect heater from gas supply if installing blower into previously installed fireplace. Contact a qualified service person to do this.

1.If fireplace screen and floor are still installed, see Removing Fireplace Screen and Floor Assembly, page 8.

2.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor.

3.Attach green ground wire from power cord to blower housing using screw provided (see Figure 14). Tighten screws securely.

4.Place the blower against lower rear wall of firebox outer wrap- per with the exhaust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Figure 14). Using 2 screws provided, mount blower and tighten screws securely.

Blower

Lower Rear

Wall of

Firebox

Screws

Exhaust

Port

exceed the size of the rectangle on template.

12. Carefully pass switch/plate assembly through rectangular open-

ing from inside mantel (see Figure 13).

Screw

Top

Mounting

Tab

Green Ground Wire

Figure 14 - Mounting Blower to Firebox (VTGF33NR/VTGF33PR

Shown)

For morevisit www..com

108117

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Fireplace Floor Assembly EFP33PR ShownUnpacking Product FeaturesLocal Codes Confined Space and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation Air From Inside Building Determining FRESH-AIR Flow for Heater LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors InstallationCheck GAS Type Installation ClearancesInstallation Sequence Removing Fireplace Screen and Floor AssemblyRelocating Wall Switch Electrical Connections for Power CordRelocating Switch and Wall Plate Ing from inside mantel see Figure Installing Variable Speed Blower AccessoryAttaching Speed Control to Firebox VTGF33NR/ VTGF33PR Shown Operating the Blower Installing Thermostatic Blower AccessoryAttaching Speed Control VTGF33NR/VTGF33PR Shown Installing GAS Piping to Fireplace Location Installation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Conventional Fireplace InstallationInstalling Cabinet Mantel BUILT-IN Fireplace InstallationAssembling and Attaching Optional Brass Trim Mantel Clearances for Built-In InstallationInstalling Hood Installing Logs VTGF33NR/VTGF33PRInstalling Installing Logs CGEFP33PR/CGEFP33NRInstalling Logs EFP33PR/EFP33NR Operating Fireplace Installing Battery Into RemoteFor Your Safety Read Before Lighting Installing ScreenTo Turn OFF GAS to Appliance Normal Lighting InstructionsOptional Blower Operation Manual Lighting Instructions for Electrical Power OutageShutting Off Heater When Manually Lit Main Burner Inspecting BurnersPilot Flame Pattern Front Burner Flame Pattern VTGF33 Series onlyLogs Cleaning MaintenanceCleaning Burner Injector Holder Cleaning Pilot AIR Inlet HoleObserved Problem Possible Cause Remedy TroubleshootingFor Com Gas leak. See Warning statement Replacement Parts SpecificationsService Hints Technical ServiceEFP33NR/EFP33PR and CGEFP33NR/CGEFP33PR VTGF33NR/VTGF33PR Wiring DiagramIllustrated Parts Breakdown KEY Part Number EFP33 CGEFP33 Description QTY Parts ListFirebox EFP33PR/NR CGEFP33PR/NR7 KEY Part Number Description QTY Firebox EFP33PR/NR CGEFP33PR/NRRemote Control LOG Base Assembly VTGF33PR and VTGF33NR Shown Contains Items 28, 30, 31, 33 Firebox VTGF33NR VTGF33PR Firebox VTGF33NR and VTGF33PR Equipment Shutoff Valve GA5010 AccessoriesBlower Accessories Corner Mantel Accessory with Fireplace Perimeter Brass TrimSlim Hearth Base Cleaning KIT CCK/GCKCorner Hearth Base Laminate Trim for Hearth or MantelFor . .com Diameter Holes TemplatesThis page Intentionally Left Blank Owners Registration Form Postage Required 108117 Not a UPC

VTGF33NR, CGEFP33PR, VTGF33PR specifications

Desa VTGF33PR, CGEFP33PR, and VTGF33NR are innovative heating solutions designed to enhance comfort and provide efficient warmth in various living spaces. These products are particularly popular for their advanced features, energy efficiency, and usability.

The Desa VTGF33PR is a natural gas vent-free infrared heater that showcases a sleek design and powerful performance. One of its standout features is its infrared technology, which allows for direct heating by warming surfaces in the room rather than just the air. This results in faster warmth and efficient energy use. The VTGF33PR also comes equipped with a thermostat, ensuring optimal temperature regulation and control over heating preferences. With a heating capacity of 33,000 BTUs, it is suitable for larger areas, providing consistent and reliable warmth even in larger spaces.

Moving on to the CGEFP33PR, this model operates on propane and combines both elegance and efficiency. This direct vent fireplace offers a unique balance between aesthetics and performance. The CGEFP33PR features a contemporary design, making it a stylish addition to modern homes. With its high-efficiency venting system, it ensures that combustion gases are safely expelled outside while maximizing heat output into the living space. It also showcases an adjustable flame feature, allowing users to set their desired ambiance while maintaining energy efficiency. Like the VTGF33PR, it includes a thermostat control for precise temperature adjustments.

Finally, the VTGF33NR is another noteworthy entry in Desa’s lineup. It operates similarly to the VTGF33PR, with a focus on infrared heating. However, the VTGF33NR distinguishes itself with its impressive portability and versatility. It is designed to be easy to install and relocate, making it a perfect choice for both homeowners and renters. Its space-saving design allows it to fit seamlessly into various room setups. This model also boasts a robust safety feature set, including an oxygen depletion sensor and an automatic shut-off mechanism, ensuring safe operation in any environment.

In summary, Desa’s VTGF33PR, CGEFP33PR, and VTGF33NR present a range of heating solutions that prioritize energy efficiency, safety, and user comfort. With advanced technologies such as infrared heating and sleek designs, these models stand out as practical solutions for any home looking to enhance its heating capabilities while maintaining modern aesthetics.