Desa VTGF33PR, VTGF33NR, CGEFP33PR installation manual Installation, Ventilation Air From Outdoors

Page 7

AIR FOR COMBUSTION AND VENTILATION

Ventilation Air (Cont.)

INSTALLATION

7

AIR FOR COMBUSTION AND VENTILATION

Continued

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 4 - Ventilation Air from Outdoors (EFP33PR Shown)

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must in- stall fireplace. Follow all local codes.

WARNING: Never install the fireplace

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the fireplace

in high traffic areas

in windy or drafty areas

CAUTION: This fireplace creates warm air cur- rents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impuri- ties (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.

Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, pages 19 and 20).

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

IMPORTANT: Make sure the fireplace is level. If fireplace is not level, log set will not work properly.

For morevisit www..com

108117

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Fireplace Floor Assembly EFP33PR ShownLocal Codes Product FeaturesUnpacking Confined Space and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation Air From Inside Building Determining FRESH-AIR Flow for Heater LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors InstallationCheck GAS Type Installation ClearancesInstallation Sequence Removing Fireplace Screen and Floor AssemblyRelocating Wall Switch Electrical Connections for Power CordRelocating Switch and Wall Plate Ing from inside mantel see Figure Installing Variable Speed Blower AccessoryAttaching Speed Control to Firebox VTGF33NR/ VTGF33PR Shown Operating the Blower Installing Thermostatic Blower AccessoryAttaching Speed Control VTGF33NR/VTGF33PR Shown Installing GAS Piping to Fireplace Location Installation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Conventional Fireplace InstallationInstalling Cabinet Mantel BUILT-IN Fireplace InstallationAssembling and Attaching Optional Brass Trim Mantel Clearances for Built-In InstallationInstalling Hood Installing Logs VTGF33NR/VTGF33PRInstalling Installing Logs CGEFP33PR/CGEFP33NRInstalling Logs EFP33PR/EFP33NR Operating Fireplace Installing Battery Into RemoteFor Your Safety Read Before Lighting Installing ScreenTo Turn OFF GAS to Appliance Normal Lighting InstructionsShutting Off Heater When Manually Lit Manual Lighting Instructions for Electrical Power OutageOptional Blower Operation Main Burner Inspecting BurnersPilot Flame Pattern Front Burner Flame Pattern VTGF33 Series onlyLogs Cleaning MaintenanceCleaning Burner Injector Holder Cleaning Pilot AIR Inlet HoleObserved Problem Possible Cause Remedy TroubleshootingFor Com Gas leak. See Warning statement Replacement Parts SpecificationsService Hints Technical ServiceEFP33NR/EFP33PR and CGEFP33NR/CGEFP33PR VTGF33NR/VTGF33PR Wiring DiagramIllustrated Parts Breakdown KEY Part Number EFP33 CGEFP33 Description QTY Parts ListFirebox EFP33PR/NR CGEFP33PR/NR7 KEY Part Number Description QTY Firebox EFP33PR/NR CGEFP33PR/NRRemote Control LOG Base Assembly VTGF33PR and VTGF33NR Shown Contains Items 28, 30, 31, 33 Firebox VTGF33NR VTGF33PR Firebox VTGF33NR and VTGF33PR Equipment Shutoff Valve GA5010 AccessoriesBlower Accessories Corner Mantel Accessory with Fireplace Perimeter Brass TrimSlim Hearth Base Cleaning KIT CCK/GCKCorner Hearth Base Laminate Trim for Hearth or MantelFor . .com Diameter Holes TemplatesThis page Intentionally Left Blank Owners Registration Form Postage Required 108117 Not a UPC

VTGF33NR, CGEFP33PR, VTGF33PR specifications

Desa VTGF33PR, CGEFP33PR, and VTGF33NR are innovative heating solutions designed to enhance comfort and provide efficient warmth in various living spaces. These products are particularly popular for their advanced features, energy efficiency, and usability.

The Desa VTGF33PR is a natural gas vent-free infrared heater that showcases a sleek design and powerful performance. One of its standout features is its infrared technology, which allows for direct heating by warming surfaces in the room rather than just the air. This results in faster warmth and efficient energy use. The VTGF33PR also comes equipped with a thermostat, ensuring optimal temperature regulation and control over heating preferences. With a heating capacity of 33,000 BTUs, it is suitable for larger areas, providing consistent and reliable warmth even in larger spaces.

Moving on to the CGEFP33PR, this model operates on propane and combines both elegance and efficiency. This direct vent fireplace offers a unique balance between aesthetics and performance. The CGEFP33PR features a contemporary design, making it a stylish addition to modern homes. With its high-efficiency venting system, it ensures that combustion gases are safely expelled outside while maximizing heat output into the living space. It also showcases an adjustable flame feature, allowing users to set their desired ambiance while maintaining energy efficiency. Like the VTGF33PR, it includes a thermostat control for precise temperature adjustments.

Finally, the VTGF33NR is another noteworthy entry in Desa’s lineup. It operates similarly to the VTGF33PR, with a focus on infrared heating. However, the VTGF33NR distinguishes itself with its impressive portability and versatility. It is designed to be easy to install and relocate, making it a perfect choice for both homeowners and renters. Its space-saving design allows it to fit seamlessly into various room setups. This model also boasts a robust safety feature set, including an oxygen depletion sensor and an automatic shut-off mechanism, ensuring safe operation in any environment.

In summary, Desa’s VTGF33PR, CGEFP33PR, and VTGF33NR present a range of heating solutions that prioritize energy efficiency, safety, and user comfort. With advanced technologies such as infrared heating and sleek designs, these models stand out as practical solutions for any home looking to enhance its heating capabilities while maintaining modern aesthetics.