Desa VTGF33PR, VTGF33NR installation manual Installing Logs CGEFP33PR/CGEFP33NR

Page 22

22

INSTALLATION

Installing Logs (VTGF33NR/VTGF33PR) (Cont.) Installing Logs (CGEFP33PR/CGEFP33NR)

INSTALLATION

Continued

 

Peg

Rear

 

 

Log (#3)

 

 

 

 

Groove

 

Groove

Crossover

 

in Back

 

Log (#4)

in Back

 

of Log

 

 

of Log

 

Cutout

Hole

Grate

 

 

Peg

Prong

 

 

 

 

Grate

 

Prong

Figure 43 - Installing

Figure 44 - Installing

Rear Log (#3)

Crossover Log (#4)

INSTALLING LOGS (CGEFP33PR/CGEFP33NR)

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: Do not remove the warning and in- struction labels attached to the heater base assem- bly. These markings contain important warranty in- formation.

CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to HIGH, check to see if flames contact any log. If so, reposition logs ac- cording to the log installation instructions in this manual. Flames contacting logs will create soot.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 45).

2.Place the base of the middle log (#2) in the U-shaped slots of the grate base in front of the back log. The cutout on the right of the middle log should fit over the burner (see Figure 46). Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner “U” bend.

3.Locate the recesses on the back of the front log (#3). Fit these recesses between the posts of the grate base (see Figure 47).

4.Locate the notches in the bottom of the crossover log (#4). Place the crossover log on top of the middle log and front log. Make sure the notches of the crossover log lines up with rectangular knobs on top of the middle and front logs (see Figure 48).

 

Back

Middle

 

 

Log

Cutout

 

Log

(#2)

 

 

Hole in

(#1)

 

 

 

 

 

Grate

 

Tab

 

Base

 

 

 

 

 

Burner

 

Burner

“U” Bend

 

U-Shaped Slot

Figure 45 - Installing Back

Figure 46 - Installing Middle

Log (#1)

Log (#2)

Front Log (#3)

 

Recess

Crossover

 

 

Log (#4)

Post

Rectangular

Post

Knobs

Figure 47 - Installing Front

Figure 48 - Installing

Log (#3)

Crossover Log (#4)

For..com

108117

Image 22
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationFireplace Floor Assembly EFP33PR Shown Product IdentificationLocal Codes Product FeaturesUnpacking Unusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined Space and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsRemoving Fireplace Screen and Floor Assembly Installation ClearancesInstallation Sequence Check GAS TypeElectrical Connections for Power Cord Relocating Wall SwitchRelocating Switch and Wall Plate Installing Variable Speed Blower Accessory Ing from inside mantel see FigureAttaching Speed Control to Firebox VTGF33NR/ VTGF33PR Shown Installing Thermostatic Blower Accessory Operating the BlowerAttaching Speed Control VTGF33NR/VTGF33PR Shown Installing GAS Piping to Fireplace Location Installation Items Needed Pressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsConventional Fireplace Installation Pressure Testing Fireplace Gas ConnectionsBUILT-IN Fireplace Installation Installing Cabinet MantelMantel Clearances for Built-In Installation Assembling and Attaching Optional Brass TrimInstalling Logs VTGF33NR/VTGF33PR Installing HoodInstalling Logs CGEFP33PR/CGEFP33NR InstallingInstalling Logs EFP33PR/EFP33NR Installing Screen Installing Battery Into RemoteFor Your Safety Read Before Lighting Operating FireplaceNormal Lighting Instructions To Turn OFF GAS to ApplianceShutting Off Heater When Manually Lit Manual Lighting Instructions for Electrical Power OutageOptional Blower Operation Front Burner Flame Pattern VTGF33 Series only Inspecting BurnersPilot Flame Pattern Main BurnerCleaning Pilot AIR Inlet Hole Cleaning MaintenanceCleaning Burner Injector Holder LogsTroubleshooting Observed Problem Possible Cause RemedyFor Com Gas leak. See Warning statement Technical Service SpecificationsService Hints Replacement PartsWiring Diagram EFP33NR/EFP33PR and CGEFP33NR/CGEFP33PR VTGF33NR/VTGF33PRIllustrated Parts Breakdown Parts List KEY Part Number EFP33 CGEFP33 Description QTYFirebox EFP33PR/NR CGEFP33PR/NR7 Firebox EFP33PR/NR CGEFP33PR/NR KEY Part Number Description QTYRemote Control LOG Base Assembly VTGF33PR and VTGF33NR Shown Contains Items 28, 30, 31, 33 Firebox VTGF33NR VTGF33PR Firebox VTGF33NR and VTGF33PR Corner Mantel Accessory with Fireplace Perimeter Brass Trim AccessoriesBlower Accessories Equipment Shutoff Valve GA5010Laminate Trim for Hearth or Mantel Cleaning KIT CCK/GCKCorner Hearth Base Slim Hearth BaseFor . .com Templates Diameter HolesThis page Intentionally Left Blank Owners Registration Form Postage Required 108117 Not a UPC

VTGF33NR, CGEFP33PR, VTGF33PR specifications

Desa VTGF33PR, CGEFP33PR, and VTGF33NR are innovative heating solutions designed to enhance comfort and provide efficient warmth in various living spaces. These products are particularly popular for their advanced features, energy efficiency, and usability.

The Desa VTGF33PR is a natural gas vent-free infrared heater that showcases a sleek design and powerful performance. One of its standout features is its infrared technology, which allows for direct heating by warming surfaces in the room rather than just the air. This results in faster warmth and efficient energy use. The VTGF33PR also comes equipped with a thermostat, ensuring optimal temperature regulation and control over heating preferences. With a heating capacity of 33,000 BTUs, it is suitable for larger areas, providing consistent and reliable warmth even in larger spaces.

Moving on to the CGEFP33PR, this model operates on propane and combines both elegance and efficiency. This direct vent fireplace offers a unique balance between aesthetics and performance. The CGEFP33PR features a contemporary design, making it a stylish addition to modern homes. With its high-efficiency venting system, it ensures that combustion gases are safely expelled outside while maximizing heat output into the living space. It also showcases an adjustable flame feature, allowing users to set their desired ambiance while maintaining energy efficiency. Like the VTGF33PR, it includes a thermostat control for precise temperature adjustments.

Finally, the VTGF33NR is another noteworthy entry in Desa’s lineup. It operates similarly to the VTGF33PR, with a focus on infrared heating. However, the VTGF33NR distinguishes itself with its impressive portability and versatility. It is designed to be easy to install and relocate, making it a perfect choice for both homeowners and renters. Its space-saving design allows it to fit seamlessly into various room setups. This model also boasts a robust safety feature set, including an oxygen depletion sensor and an automatic shut-off mechanism, ensuring safe operation in any environment.

In summary, Desa’s VTGF33PR, CGEFP33PR, and VTGF33NR present a range of heating solutions that prioritize energy efficiency, safety, and user comfort. With advanced technologies such as infrared heating and sleek designs, these models stand out as practical solutions for any home looking to enhance its heating capabilities while maintaining modern aesthetics.