Desa CGEFP33PR, VTGF33NR Specifications, Service Hints, Technical Service, Replacement Parts

Page 32

32

SPECIFICATIONS

SERVICE HINTS TECHNICAL SERVICE REPLACEMENT PARTS

SPECIFICATIONS

Btu (Variable)

20,000/33,000

 

Type Gas

Natural: (CG)EFP33NR, VTGF33NR

 

Propane/LP: (CG)EFP33PR, VTGF33PR

Ignition

Electronic (Automatic)/Piezo (Manual)

 

Natural Gas

Propane/LP Gas

Manifold Pressure

3.5" W.C.8.0" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

14"

Minimum*

5"

11"

Shipping Weight

122 lbs.

122 lbs.

* For input adjustment

 

 

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040.

You can also visit DESA International’s technical service web site at www.desatech.com.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040.

When calling DESA International, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

For..com

108117

Image 32
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationFireplace Floor Assembly EFP33PR Shown Product IdentificationUnpacking Product FeaturesLocal Codes AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined Space and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Ventilation AIRDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsInstallation Clearances Installation SequenceRemoving Fireplace Screen and Floor Assembly Check GAS TypeElectrical Connections for Power Cord Relocating Wall SwitchRelocating Switch and Wall Plate Installing Variable Speed Blower Accessory Ing from inside mantel see FigureAttaching Speed Control to Firebox VTGF33NR/ VTGF33PR Shown Installing Thermostatic Blower Accessory Operating the BlowerAttaching Speed Control VTGF33NR/VTGF33PR Shown Installing GAS Piping to Fireplace Location Installation Items Needed Connecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsConventional Fireplace Installation Pressure Testing Fireplace Gas ConnectionsBUILT-IN Fireplace Installation Installing Cabinet MantelMantel Clearances for Built-In Installation Assembling and Attaching Optional Brass TrimInstalling Logs VTGF33NR/VTGF33PR Installing HoodInstalling Logs CGEFP33PR/CGEFP33NR InstallingInstalling Logs EFP33PR/EFP33NR Installing Battery Into Remote For Your Safety Read Before LightingInstalling Screen Operating FireplaceNormal Lighting Instructions To Turn OFF GAS to ApplianceOptional Blower Operation Manual Lighting Instructions for Electrical Power OutageShutting Off Heater When Manually Lit Inspecting Burners Pilot Flame PatternFront Burner Flame Pattern VTGF33 Series only Main BurnerCleaning Maintenance Cleaning Burner Injector HolderCleaning Pilot AIR Inlet Hole LogsTroubleshooting Observed Problem Possible Cause RemedyFor Com Gas leak. See Warning statement Specifications Service HintsTechnical Service Replacement PartsWiring Diagram EFP33NR/EFP33PR and CGEFP33NR/CGEFP33PR VTGF33NR/VTGF33PRIllustrated Parts Breakdown Parts List KEY Part Number EFP33 CGEFP33 Description QTYFirebox EFP33PR/NR CGEFP33PR/NR7 Firebox EFP33PR/NR CGEFP33PR/NR KEY Part Number Description QTYRemote Control LOG Base Assembly VTGF33PR and VTGF33NR Shown Contains Items 28, 30, 31, 33 Firebox VTGF33NR VTGF33PR Firebox VTGF33NR and VTGF33PR Accessories Blower AccessoriesCorner Mantel Accessory with Fireplace Perimeter Brass Trim Equipment Shutoff Valve GA5010Cleaning KIT CCK/GCK Corner Hearth BaseLaminate Trim for Hearth or Mantel Slim Hearth BaseFor . .com Templates Diameter HolesThis page Intentionally Left Blank Owners Registration Form Postage Required 108117 Not a UPC

VTGF33NR, CGEFP33PR, VTGF33PR specifications

Desa VTGF33PR, CGEFP33PR, and VTGF33NR are innovative heating solutions designed to enhance comfort and provide efficient warmth in various living spaces. These products are particularly popular for their advanced features, energy efficiency, and usability.

The Desa VTGF33PR is a natural gas vent-free infrared heater that showcases a sleek design and powerful performance. One of its standout features is its infrared technology, which allows for direct heating by warming surfaces in the room rather than just the air. This results in faster warmth and efficient energy use. The VTGF33PR also comes equipped with a thermostat, ensuring optimal temperature regulation and control over heating preferences. With a heating capacity of 33,000 BTUs, it is suitable for larger areas, providing consistent and reliable warmth even in larger spaces.

Moving on to the CGEFP33PR, this model operates on propane and combines both elegance and efficiency. This direct vent fireplace offers a unique balance between aesthetics and performance. The CGEFP33PR features a contemporary design, making it a stylish addition to modern homes. With its high-efficiency venting system, it ensures that combustion gases are safely expelled outside while maximizing heat output into the living space. It also showcases an adjustable flame feature, allowing users to set their desired ambiance while maintaining energy efficiency. Like the VTGF33PR, it includes a thermostat control for precise temperature adjustments.

Finally, the VTGF33NR is another noteworthy entry in Desa’s lineup. It operates similarly to the VTGF33PR, with a focus on infrared heating. However, the VTGF33NR distinguishes itself with its impressive portability and versatility. It is designed to be easy to install and relocate, making it a perfect choice for both homeowners and renters. Its space-saving design allows it to fit seamlessly into various room setups. This model also boasts a robust safety feature set, including an oxygen depletion sensor and an automatic shut-off mechanism, ensuring safe operation in any environment.

In summary, Desa’s VTGF33PR, CGEFP33PR, and VTGF33NR present a range of heating solutions that prioritize energy efficiency, safety, and user comfort. With advanced technologies such as infrared heating and sleek designs, these models stand out as practical solutions for any home looking to enhance its heating capabilities while maintaining modern aesthetics.