OPERATING FIREPLACE

Continued

WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Fireplace will come on automati- cally with selector switch in the ON position.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to keep from draining the battery.

Shutting Off Burner Only (pilot stays lit) You may shut off the burner and keep the pilot lit by doing one of the following:

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 20.

2.Press control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions, page 20.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page

38). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 20 .

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 41). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

Flame Adjustment Knob

Control Knob

Selector Switch in Remote

Position (Optional Hand-

in On Position

Held Remote Control)

 

Figure 41 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

ON/OFF SERIES (MODEL GHRCB)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 42).

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 42 - On/Off Hand-Held Remote Control Unit (GHRCB)

113109-01B

www.desatech.com

21

Image 21
Contents Patent Pending What to do if YOU Smell GASTable of Contents Safety Information Product Identification Log Base AssemblyLocal Codes Product FeaturesUnpacking AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Hood InstallationCheck GAS Type Electrical HookupRepeat steps 1 through 6 for other side Installation ClearancesPlacing Hearth Base Accessory Against Wall Conventional Fireplace InstallationModels VYGF33PRB and VYGF33NRB BUILT-IN Fireplace InstallationModels FPVF33PRA and FPVF33NRA Connecting Duplex OutletInstalling GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Natural GasPropane/LP Test Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressurize supply piping system by eitherVygf Models Only Installing LogsFpvf Models Only Installing Remote Receiver UnitFor Your Safety Read Before Lighting Installing 9-VOLT BatteriesInstalling 9-Volt Battery in Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitPilot Propane/LP Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model GhrcbOptional Blower Operation Thermostat Series Model GhrctbPilot Flame Pattern Inspecting BurnerBurner Flame Pattern Burner Primary AIR HolesCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingDiagram, Maintenance, Gas leak. See Warning Fireplace produces unwantedSpecifications Wiring DiagramReplacement Parts Technical ServiceModels VYGF33PRC and VYGF33NRC Shown Illustrated Parts BreakdownParts List Models FPVF33PRA and FPVF33NRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox Models VYGF33PRC and VYGF33NRC KEY Part Number Description QTY Firebox Models FPVF33PRA and FPVF33NRA Parts List Accessories WALL-MOUNT ON/OFF Switch Receiver and HAND-HELD Remote Control KIT Ghrcb SeriesCabinet Mantel and Full Hearth Base Laminate Trim for Hearth or MantelWarranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace