Desa VYGF33PRC installation manual Lighting Instructions, Pilot Propane/LP

Page 20

OPERATING FIREPLACE

Continued

LIGHTING

INSTRUCTIONS

WARNING:You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.

STOP! Read the safety information, page

 

19, column 2.

2.

Make sure equipment shutoff valve is fully

 

open.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 21.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob coun-

terclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burner.

11.Set flame adjustment knob to any level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

3. Set selector switch in OFF position.

WARNING: Burner will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

Control Knob

IH

 

N

O

O

F

LO

F

TOLI

 

P

Ignitor Button

AUTO

OFF

ON

4.Press in and turn control knob clockwise to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 19, column 2. If you donʼt smell gas, go to the next step.

6.Press in and turn control knob counter-

clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 38).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Flame Adjustment

Selector Switch

Knob

 

Figure 38 - Control Knob and Ignitor

Button Location (Shown as Supplied, No

Control Options)

Pilot Burner

Ignitor

Electrode

 

Figure 39 - Pilot (Propane/LP)

 

Ignitor

Pilot Burner

Electrode

Figure 40 - Pilot (Natural)

20

www.desatech.com

113109-01B

Image 20
Contents What to do if YOU Smell GAS Patent PendingTable of Contents Safety Information Log Base Assembly Product IdentificationProduct Features Local CodesUnpacking AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances Repeat steps 1 through 6 for other sideConventional Fireplace Installation Placing Hearth Base Accessory Against WallBUILT-IN Fireplace Installation Models VYGF33PRB and VYGF33NRBConnecting Duplex Outlet Models FPVF33PRA and FPVF33NRAInstallation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Propane/LP Connecting Fireplace to GAS SupplyNatural Gas Checking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaPressurize supply piping system by either Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Logs Vygf Models OnlyInstalling Remote Receiver Unit Fpvf Models OnlyInstalling 9-VOLT Batteries For Your Safety Read Before LightingInstalling 9-Volt Battery in Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitLighting Instructions Pilot Propane/LPManual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation ON/OFF Series Model GhrcbThermostat Series Model Ghrctb Optional Blower OperationInspecting Burner Pilot Flame PatternBurner Flame Pattern Burner Primary AIR HolesLogs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyDiagram, Maintenance, Fireplace produces unwanted Gas leak. See WarningWiring Diagram SpecificationsReplacement Parts Technical ServiceIllustrated Parts Breakdown Models VYGF33PRC and VYGF33NRC ShownParts List Models FPVF33PRA and FPVF33NRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox Models VYGF33PRC and VYGF33NRC KEY Part Number Description QTY Firebox Models FPVF33PRA and FPVF33NRA Parts List Accessories Receiver and HAND-HELD Remote Control KIT Ghrcb Series WALL-MOUNT ON/OFF SwitchCabinet Mantel and Full Hearth Base Laminate Trim for Hearth or MantelLimited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty