Desa VYGF33PRC Local Codes, Unpacking, Product Features, AIR for Combustion Ventilation

Page 5

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

CAUTION: Do not remove the dataplatesattachedtotheheater base assembly. The data plates contain important warranty and safety information.

1.With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the carton off the heater. Remove packing. Note: The hood is located in the packing on the right hand side of the heater front. Lift the heater off the bottom tray.

2.Locate two screws above top corners of the fireplace screen. Remove and discard these screws. Lift fireplace screen up and pull out to remove.

3.Remove protective packaging applied to logs, log base assembly and fireplace.

4.Remove fireplace hood from carton insert.

5.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought fireplace.

PRODUCT FEATURES

OPERATION

This vent-free fireplace is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames. When used without the blower, the fireplace requires no electricity making it ideal for emergency backup heat. This heater is designed for vent-free operation. It has been tested and ap- proved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas pro- hibit the use of vent-free heaters.

SAFETY DEVICE

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/ pilot is a required feature for vent-free room heat- ers. The ODS/pilot system shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system requires no matches, batteries or other sources to light fireplace.

OPTIONAL REMOTE CONTROL UNITS

There are four optional remote controls that can be purchased separately for this log heater:

wall switch

wall thermostat

hand-held ON/OFF remote

hand-held thermostat remote See Accessories, page 38.

OPTIONAL BLOWER ASSEMBLY (GA3700 SERIES & GA3700T

SERIES)

This fireplace accepts an optional blower assembly (not included). The GA3700T Series blower oper- ates thermostatically and features a variable speed control. The GA3700 Series blower operates man- ually and also features a variable speed control. The blower circulates heated air from the fireplace into the room. See Accessories, page 38.

AIR FOR COMBUSTION

AND VENTILATION

WARNING: This heater shall not be installed in a confined spaceorunusuallytightconstruc- tion unless provisions are provid- ed for adequate combustion and ventilation air. Read the following instructionstoinsureproperfresh air for this and other fuel-burning appliances in your home.

Todayʼs homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

113109-01B

www.desatech.com

5

Image 5
Contents Patent Pending What to do if YOU Smell GASTable of Contents Safety Information Product Identification Log Base AssemblyLocal Codes Product FeaturesUnpacking AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing Hood InstallationCheck GAS Type Electrical HookupRepeat steps 1 through 6 for other side Installation ClearancesPlacing Hearth Base Accessory Against Wall Conventional Fireplace InstallationModels VYGF33PRB and VYGF33NRB BUILT-IN Fireplace InstallationModels FPVF33PRA and FPVF33NRA Connecting Duplex OutletInstallation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Propane/LP Connecting Fireplace to GAS SupplyNatural Gas Test Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressurize supply piping system by eitherVygf Models Only Installing LogsFpvf Models Only Installing Remote Receiver UnitFor Your Safety Read Before Lighting Installing 9-VOLT BatteriesInstalling 9-Volt Battery in Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitPilot Propane/LP Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model GhrcbOptional Blower Operation Thermostat Series Model GhrctbPilot Flame Pattern Inspecting BurnerBurner Flame Pattern Burner Primary AIR HolesLogs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingDiagram, Maintenance, Gas leak. See Warning Fireplace produces unwantedSpecifications Wiring DiagramReplacement Parts Technical ServiceModels VYGF33PRC and VYGF33NRC Shown Illustrated Parts BreakdownParts List Models FPVF33PRA and FPVF33NRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox Models VYGF33PRC and VYGF33NRC KEY Part Number Description QTY Firebox Models FPVF33PRA and FPVF33NRA Parts List Accessories WALL-MOUNT ON/OFF Switch Receiver and HAND-HELD Remote Control KIT Ghrcb SeriesCabinet Mantel and Full Hearth Base Laminate Trim for Hearth or MantelLimited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty