SAFETY INFORMATION

WARNING:Thisproductcon- tainsand/orgenerateschemicals known to the state of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with head- aches, dizziness or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

Natural and Propane/LP Gas: Natural and Propane/LP gases are odorless. An odor-making agent is added to these gases. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not ap- proved for use with this heater.

WARNING: Do not allow fans toblowdirectly intothe fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Fireplace front and screen be- come very hot when running fire- place. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fire- place will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carefully supervise young chil- dren when they are in the room with fireplace. When using the optional hand-held remote ac- cessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this fireplace with the fireplace screen and hood in place. Make sure fire- place screen and hood are in place before running fireplace.

Keep the appliance area clear and free from combustible ma- terials, gasoline and other flam- mable vapors and liquids.

113109-01B

www.desatech.com

3

Image 3
Contents Patent Pending What to do if YOU Smell GASTable of Contents Safety Information Product Identification Log Base AssemblyAIR for Combustion Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeRepeat steps 1 through 6 for other side Installation ClearancesPlacing Hearth Base Accessory Against Wall Conventional Fireplace InstallationModels VYGF33PRB and VYGF33NRB BUILT-IN Fireplace InstallationModels FPVF33PRA and FPVF33NRA Connecting Duplex OutletInstalling GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Natural GasPropane/LP Test Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressurize supply piping system by eitherVygf Models Only Installing LogsFpvf Models Only Installing Remote Receiver UnitInstalling 9-Volt Battery in Hand-Held Remote Control Unit Installing 9-VOLT BatteriesFor Your Safety Read Before Lighting Installing 9-Volt Battery in ReceiverPilot Propane/LP Lighting InstructionsON/OFF Series Model Ghrcb Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationOptional Blower Operation Thermostat Series Model GhrctbBurner Primary AIR Holes Inspecting BurnerPilot Flame Pattern Burner Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingDiagram, Maintenance, Gas leak. See Warning Fireplace produces unwantedTechnical Service Wiring DiagramSpecifications Replacement PartsModels VYGF33PRC and VYGF33NRC Shown Illustrated Parts BreakdownParts List Models FPVF33PRA and FPVF33NRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox Models VYGF33PRC and VYGF33NRC KEY Part Number Description QTY Firebox Models FPVF33PRA and FPVF33NRA Parts List Accessories Laminate Trim for Hearth or Mantel Receiver and HAND-HELD Remote Control KIT Ghrcb SeriesWALL-MOUNT ON/OFF Switch Cabinet Mantel and Full Hearth BaseWarranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace