Desa EFP33PR, EFP33NR installation manual Owner’S Operation And Installation Manual

Page 1
UNVENTED (VENT-FREE)

UNVENTED (VENT-FREE)

GAS FIREPLACE

TM

OWNER’S OPERATION AND INSTALLATION MANUAL

OWNER’S OPERATION AND INSTALLATION MANUALFor..comCGEFP33PR, CGEFP33NR, EFP33PR, and EFP33NRGas Fireplace with Total Control System (TCS)—WHAT TO DO IF YOU SMELL GASFor•Do not try to light any appliance.Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

Shown with optional cabinet mantel,

Shown with optional hearth

hearth base, and trim accessories.

base accessory.

CGEFP33PR, CGEFP33NR, EFP33PR, and EFP33NR

Gas Fireplace with Total Control System (TCS)

WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency, or the gas supplier.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assis- tance or additional information con- sult a qualified installer, service agency, or the gas supplier.

WARNING: This is an unvented gas- fired heater. It uses air (oxygen) from the room in which it is in- stalled. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Com- bustion and Ventilation section on page 5 of this manual.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Manual backgroundManual backgroundSave thisManual backgroundManual backgroundfor futureManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Image 1
Contents WHAT TO DO IF YOU SMELL GAS OWNER’S OPERATION AND INSTALLATION MANUALDo not try to light any appliance UNVENTED VENT-FREE GAS FIREPLACESAFETY INFORMATION TABLE OF CONTENTSWARNINGS Continued PRODUCT IDENTIFICATIONSAFETY INFORMATION SAFETY DEVICE PRODUCT FEATURESWIRELESS REMOTE CONTROL WIRED WALL-MOUNTEDREMOTE CONTROLPROVIDING ADEQUATE VENTILATION AIR FOR COMBUSTION AND VENTILATIONVENTILATION AIR DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONAIR FOR COMBUSTION AND VENTILATION ContinuedAIR FOR COMBUSTION AND VENTILATION INSTALLATIONContinued Ventilation Air From OutdoorsINSTALLATION SEQUENCE INSTALLATION CLEARANCESREMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLY CHECK GAS TYPERELOCATING WALL SWITCH ELECTRICAL CONNECTIONS FOR POWER CORDINSTALLATION ContinuedFor Mantel Installation INSTALLATIONContinued CAUTION Do not apply excessive pull on cordINSTALLATION INSTALLING VARIABLE SPEED BLOWER ACCESSORYContinued 8.Plug in blower power cord INSTALLATIONContinued INSTALLATION INSTALLING THERMOSTATIC BLOWER ACCESSORYFireplace Screen and Floor Assembly, page Continued12.Plug in blower power cord INSTALLATIONContinued INSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONINSTALLATION ContinuedInstallation Items Needed INSTALLATIONContinued CHECKING GAS CONNECTIONS CONNECTING FIREPLACE TO GAS SUPPLYINSTALLATION ContinuedINSTALLATION CONVENTIONAL FIREPLACE INSTALLATIONContinued necting Fireplace to Gas Supply, pageINSTALLATION BUILT-INFIREPLACE INSTALLATIONContinued ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIM Included with Mantel AccessoryINSTALLATION ContinuedINSTALLING HOOD INSTALLING LOGS CGEFP33PR/CGEFP33NRINSTALLATION ContinuedINSTALLATION INSTALLING LOGS EFP33PR/EFP33NRContinued FOR YOUR SAFETY READ BEFORE LIGHTING INSTALLING BATTERY INTO REMOTEINSTALLING SCREEN OPERATING FIREPLACETO TURN OFF GAS TO APPLIANCE NORMAL LIGHTING INSTRUCTIONSOPERATING FIREPLACE ContinuedMANUAL LIGHTING INSTRUCTIONS FOR ELECTRICAL POWER OUTAGEOPTIONAL BLOWER OPERATION OPERATING FIREPLACECLEANING BURNER INJECTOR HOLDER CLEANING AND MAINTENANCEINSPECTING BURNERS PILOT FLAME PATTERNSERVICE HINTS SPECIFICATIONSTECHNICAL SERVICE CLEANING PILOT AIR INLET HOLERefer to Air for Combustion and Venti TROUBLESHOOTINGContinued TROUBLESHOOTINGHeater produces a whistling noise when Continued TROUBLESHOOTINGing Gas Connections, pages 17 and ing Gas Connections, pages 17 andREPLACEMENT PARTS WIRING DIAGRAMPARTS UNDER WARRANTY PARTS NOT UNDER WARRANTYLOG BASE ASSEMBLY MODELS REMOTE CONTROLILLUSTRATED PARTS BREAKDOWNPARTS LIST PARTS LISTPART NUMBER EFP33FIREBOX MODELS EFP33PR/NR AND CGEFP33PR/NR7 ILLUSTRATED PARTS BREAKDOWNILLUSTRATED PARTS BREAKDOWN Models EFP33PR/NR and CGEFP33PR/NRPARTS LIST FIREBOX MODELS EFP33PR/NR AND CGEFP33PR/NRPARTS LIST PART NUMBERBLOWER ACCESSORIES ACCESSORIESBRASS TRIM ACCESSORY Not Shown CLEANING KIT - CCK/GCKHEARTH BASE for Use with Cabinet Mantel LAMINATE TRIM FOR HEARTH OR MANTELCORNER HEARTH BASE SLIM HEARTH BASEPage 3/8 Diameter 2 Holes 3/4 TEMPLATES1/8 Diameter 2 Holes 3/4 4 3/4 3 3/4 3/8108117-01H THIS PAGE INTENTIONALLY LEFT BLANKOWNERS REGISTRATION FORM Postage Required TAPETAPE 2701 Industrial Drive P.O. Box Bowling Green, KYPage 2701 Industrial Drive P.O. Box Bowling Green, KY NOT A UPC