Desa EFP33NR Check Gas Type, Electrical Hookup, Installation Clearances, Installation Sequence

Page 8
CHECK GAS TYPE

8

INSTALLATION

Check Gas Type

 

Electrical Hookup

 

Installation Clearances

 

Installation Sequence

 

Removing Fireplace Screen And Floor Assembly

 

 

INSTALLATION

Continued

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

ELECTRICAL HOOKUP

This fireplace normally operates under 120 VAC/60 Hz line volt- age. The electrical cord supplied with your fireplace is five feet in length. You must locate fireplace within reach of a 120 volt grounded electrical outlet. If not, you must install an electrical outlet within reach of the fireplace power cord. The GA3555 outlet accessory may be used for built-in applications.

INSTALLATION CLEARANCES

ELECTRICAL HOOKUP WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceil- ing, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 5.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace cabinet (see Figure 5).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

Example

*

*Minimum 16 inches from Side Wall

Figure 5 - Minimum Clearance for Combustible to Wall

INSTALLATION SEQUENCE

After unpacking fireplace (see Unpacking, page 4), we suggest that you install your fireplace system in the following sequence:

1.Removal of fireplace floor assembly (required)

2.Electrical connections for power cord (required)

3.Relocating wall switch (optional)

4.Installing blower accessory (optional)

5.Connecting fireplace to gas supply (required)

6.Checking gas connections (required)

7.Firebox installation, conventional or built-in (required)

8.Installing brass perimeter trim (optional)

9.Installing fireplace hood (required)

10.Installing logs (required)

11.Installing fireplace screen (required)

Use the following instructions to complete each step.

REMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLY

NOTICE: Shutoff gas supply and disconnect heater from gas supply if installing blower into previously installed fireplace. Contact a qualified service person to do this.

1.Remove fireplace screen. Remove two screws that hold fire- place screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.If logs are installed, carefully remove the logs and set aside, noting the properly mounted location of each.

3.Remove screws that attach fireplace floor assembly to fire- place. Open lower louver door. Carefully lift up fireplace floor assembly and remove from fireplace, taking care to pull flex- ible gas line through the access holes (see Figure 6, page 9). Note: Be careful of all wires on underside of log base.

INSTALLATION CLEARANCES CAUTION: Do not pick up fireplace floor assembly by burners. This could damage burners. Only handle base by grates.

INSTALLATION SEQUENCEREMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLYManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

108117-01H

Image 8
Contents OWNER’S OPERATION AND INSTALLATION MANUAL WHAT TO DO IF YOU SMELL GASDo not try to light any appliance UNVENTED VENT-FREE GAS FIREPLACEWARNINGS TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION PRODUCT IDENTIFICATIONContinued PRODUCT FEATURES SAFETY DEVICEWIRELESS REMOTE CONTROL WIRED WALL-MOUNTEDREMOTE CONTROLAIR FOR COMBUSTION AND VENTILATION PROVIDING ADEQUATE VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION VENTILATION AIRAIR FOR COMBUSTION AND VENTILATION ContinuedINSTALLATION AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From OutdoorsINSTALLATION CLEARANCES INSTALLATION SEQUENCEREMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLY CHECK GAS TYPEELECTRICAL CONNECTIONS FOR POWER CORD RELOCATING WALL SWITCHINSTALLATION ContinuedINSTALLATION For Mantel InstallationContinued CAUTION Do not apply excessive pull on cordContinued INSTALLING VARIABLE SPEED BLOWER ACCESSORYINSTALLATION Continued INSTALLATION8.Plug in blower power cord INSTALLING THERMOSTATIC BLOWER ACCESSORY INSTALLATIONFireplace Screen and Floor Assembly, page ContinuedContinued INSTALLATION12.Plug in blower power cord INSTALLING GAS PIPING TO FIREPLACE LOCATION INSTALLATIONINSTALLATION ContinuedContinued INSTALLATIONInstallation Items Needed CONNECTING FIREPLACE TO GAS SUPPLY CHECKING GAS CONNECTIONSINSTALLATION ContinuedCONVENTIONAL FIREPLACE INSTALLATION INSTALLATIONContinued necting Fireplace to Gas Supply, pageContinued BUILT-INFIREPLACE INSTALLATIONINSTALLATION Included with Mantel Accessory ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIMINSTALLATION ContinuedINSTALLING LOGS CGEFP33PR/CGEFP33NR INSTALLING HOODINSTALLATION ContinuedContinued INSTALLING LOGS EFP33PR/EFP33NRINSTALLATION INSTALLING BATTERY INTO REMOTE FOR YOUR SAFETY READ BEFORE LIGHTINGINSTALLING SCREEN OPERATING FIREPLACENORMAL LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEOPERATING FIREPLACE ContinuedELECTRICAL POWER OUTAGE MANUAL LIGHTING INSTRUCTIONS FOROPTIONAL BLOWER OPERATION OPERATING FIREPLACECLEANING AND MAINTENANCE CLEANING BURNER INJECTOR HOLDERINSPECTING BURNERS PILOT FLAME PATTERNSPECIFICATIONS SERVICE HINTSTECHNICAL SERVICE CLEANING PILOT AIR INLET HOLETROUBLESHOOTING Refer to Air for Combustion and VentiHeater produces a whistling noise when TROUBLESHOOTINGContinued TROUBLESHOOTING Continueding Gas Connections, pages 17 and ing Gas Connections, pages 17 andWIRING DIAGRAM REPLACEMENT PARTSPARTS UNDER WARRANTY PARTS NOT UNDER WARRANTYREMOTE CONTROL LOG BASE ASSEMBLY MODELSILLUSTRATED PARTS BREAKDOWNPARTS LIST PARTS LISTPART NUMBER EFP33ILLUSTRATED PARTS BREAKDOWN FIREBOX MODELS EFP33PR/NR AND CGEFP33PR/NR7ILLUSTRATED PARTS BREAKDOWN Models EFP33PR/NR and CGEFP33PR/NRFIREBOX MODELS EFP33PR/NR AND CGEFP33PR/NR PARTS LISTPARTS LIST PART NUMBERACCESSORIES BLOWER ACCESSORIESBRASS TRIM ACCESSORY Not Shown CLEANING KIT - CCK/GCKLAMINATE TRIM FOR HEARTH OR MANTEL HEARTH BASE for Use with Cabinet MantelCORNER HEARTH BASE SLIM HEARTH BASEPage TEMPLATES 3/8 Diameter 2 Holes 3/41/8 Diameter 2 Holes 3/4 4 3/4 3 3/4 3/8THIS PAGE INTENTIONALLY LEFT BLANK 108117-01HOWNERS REGISTRATION FORM TAPE Postage RequiredTAPE 2701 Industrial Drive P.O. Box Bowling Green, KYPage NOT A UPC 2701 Industrial Drive P.O. Box Bowling Green, KY