Desa EFP33NR, EFP33PR installation manual Installation, Continued, Plug in blower power cord

Page 14
12.Plug in blower power cord.

14

INSTALLATION

Installing Thermostatic Blower Accessory (Cont.)

INSTALLATION

Continued

10.Place control knob provided on plastic control shaft of speed control (see Figure 20).

11.Mount the speed control onto the front leg of the left floor support bracket using 2 screws provided (see Figure 20).

Manual background WARNING: Failure to connect all wires properly as indicated may cause electrical short circuit or personal injury. A qualified electrician should check that all connections are made properly.

12.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Install one plastic bushing provided into the 1 1/2" hole in the floor sup- port on the exit side. Install the second bushing provided into the 1 1/2" hole in the outer casing through which the power cord will exit (see Figures 21 and 22). Route power cord through plastic bushings and plug the power cord into a prop- erly grounded three-prong wall receptacle near the firebox.

b.If your fireplace system installation is recessed and if an outlet is not installed in your fireplace, you must install the GA3555 Outlet kit with cover in your fireplace which will supply a convenient 3-prong grounded electrical outlet for your blower. Refer to the installation manual provided with the model GA3555 accessory for instructions on wir- ing the duplex outlet.

Note:A qualified installer must make all electrical connections.

Blower

Lower

Rear Wall

of Firebox

#8 Screws

Exhaust

Manual background Port

Top

Manual background Mounting

Tab

Figure 19 - Mounting Blower to Firebox

13.Check to make sure that the power cord and all wires are com- pletely clear of the blower wheel and that there are no other foreign objects in blower wheel.

Manual background CAUTION: Never touch the blower wheel while in operation.

14.Peel off backing paper and stick supplied wiring diagram de- cal near center of firebox bottom (see Figure 23, page 15).

Floor

Support

Bracket

Speed Control

ScrewsManual background

Control Knob

Figure 20 - Attaching Speed Control

 

Plastic

Right Floor

Bushing

Support Bracket

 

Figure 21 - Installing Plastic Bushing for Power Cord (Right Side Exit Shown)

Bushing

Plastic

Bushing

Location for

Bushing Location

Freestanding

for Recessed

Installation

Installation

 

Figure 22 - Installing Bushings (Left Side Exit shown)

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

108117-01H

Image 14
Contents Do not try to light any appliance OWNER’S OPERATION AND INSTALLATION MANUALWHAT TO DO IF YOU SMELL GAS UNVENTED VENT-FREE GAS FIREPLACEWARNINGS TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION PRODUCT IDENTIFICATIONContinued WIRELESS REMOTE CONTROL PRODUCT FEATURESSAFETY DEVICE WIRED WALL-MOUNTEDREMOTE CONTROLAIR FOR COMBUSTION AND VENTILATION PROVIDING ADEQUATE VENTILATIONAIR FOR COMBUSTION AND VENTILATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONVENTILATION AIR ContinuedContinued INSTALLATIONAIR FOR COMBUSTION AND VENTILATION Ventilation Air From OutdoorsREMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLY INSTALLATION CLEARANCESINSTALLATION SEQUENCE CHECK GAS TYPEINSTALLATION ELECTRICAL CONNECTIONS FOR POWER CORDRELOCATING WALL SWITCH ContinuedContinued INSTALLATIONFor Mantel Installation CAUTION Do not apply excessive pull on cordContinued INSTALLING VARIABLE SPEED BLOWER ACCESSORYINSTALLATION Continued INSTALLATION8.Plug in blower power cord Fireplace Screen and Floor Assembly, page INSTALLING THERMOSTATIC BLOWER ACCESSORYINSTALLATION ContinuedContinued INSTALLATION12.Plug in blower power cord INSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONINSTALLATION ContinuedContinued INSTALLATIONInstallation Items Needed INSTALLATION CONNECTING FIREPLACE TO GAS SUPPLYCHECKING GAS CONNECTIONS ContinuedContinued CONVENTIONAL FIREPLACE INSTALLATIONINSTALLATION necting Fireplace to Gas Supply, pageContinued BUILT-INFIREPLACE INSTALLATIONINSTALLATION INSTALLATION Included with Mantel AccessoryASSEMBLING AND ATTACHING OPTIONAL BRASS TRIM ContinuedINSTALLATION INSTALLING LOGS CGEFP33PR/CGEFP33NRINSTALLING HOOD ContinuedContinued INSTALLING LOGS EFP33PR/EFP33NRINSTALLATION INSTALLING SCREEN INSTALLING BATTERY INTO REMOTEFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACEOPERATING FIREPLACE NORMAL LIGHTING INSTRUCTIONSTO TURN OFF GAS TO APPLIANCE ContinuedOPTIONAL BLOWER OPERATION ELECTRICAL POWER OUTAGEMANUAL LIGHTING INSTRUCTIONS FOR OPERATING FIREPLACEINSPECTING BURNERS CLEANING AND MAINTENANCECLEANING BURNER INJECTOR HOLDER PILOT FLAME PATTERNTECHNICAL SERVICE SPECIFICATIONSSERVICE HINTS CLEANING PILOT AIR INLET HOLETROUBLESHOOTING Refer to Air for Combustion and VentiHeater produces a whistling noise when TROUBLESHOOTINGContinued ing Gas Connections, pages 17 and TROUBLESHOOTINGContinued ing Gas Connections, pages 17 andPARTS UNDER WARRANTY WIRING DIAGRAMREPLACEMENT PARTS PARTS NOT UNDER WARRANTYILLUSTRATED PARTS REMOTE CONTROLLOG BASE ASSEMBLY MODELS BREAKDOWNPART NUMBER PARTS LISTPARTS LIST EFP33ILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWNFIREBOX MODELS EFP33PR/NR AND CGEFP33PR/NR7 Models EFP33PR/NR and CGEFP33PR/NRPARTS LIST FIREBOX MODELS EFP33PR/NR AND CGEFP33PR/NRPARTS LIST PART NUMBERBRASS TRIM ACCESSORY Not Shown ACCESSORIESBLOWER ACCESSORIES CLEANING KIT - CCK/GCKCORNER HEARTH BASE LAMINATE TRIM FOR HEARTH OR MANTELHEARTH BASE for Use with Cabinet Mantel SLIM HEARTH BASEPage 1/8 Diameter 2 Holes 3/4 TEMPLATES3/8 Diameter 2 Holes 3/4 4 3/4 3 3/4 3/8THIS PAGE INTENTIONALLY LEFT BLANK 108117-01HOWNERS REGISTRATION FORM TAPE TAPEPostage Required 2701 Industrial Drive P.O. Box Bowling Green, KYPage NOT A UPC 2701 Industrial Drive P.O. Box Bowling Green, KY