Desa EFP33NR, EFP33PR installation manual Continued, Installation Items Needed

Page 16
Installation Items Needed

16

INSTALLATION

Installing Gas Piping to Fireplace Location (Cont.)

INSTALLATION

Continued

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer, for propane/LP units only)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by lo- cal codes) (not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 36 and 37.

For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 24. Pointing the vent down protects it from freezing rain or sleet.

We recommend that you install a sediment trap in supply line as shown in Figure 25. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

External

Regulator Propane/LP

Supply Tank

Vent

Pointing

Down

Figure 24 - External Regulator with Vent Pointing Down

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

Manual background CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 24).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

3" Minimum Manual backgroundManual background

Pipe Cap Tee

Nipple Joint

Sediment Trap

Figure 25 - Gas Connection

Natural

From Gas Meter (5" W.C. to 10.5" W.C. Pressure)

Propane/LP

From External Regulator (11" W.C. to 14 " W.C. Pressure

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. Never use sealant on flare threads.

Manual background WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 36 and 37.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

108117-01H

Image 16
Contents OWNER’S OPERATION AND INSTALLATION MANUAL WHAT TO DO IF YOU SMELL GASDo not try to light any appliance UNVENTED VENT-FREE GAS FIREPLACESAFETY INFORMATION TABLE OF CONTENTSWARNINGS Continued PRODUCT IDENTIFICATIONSAFETY INFORMATION PRODUCT FEATURES SAFETY DEVICEWIRELESS REMOTE CONTROL WIRED WALL-MOUNTEDREMOTE CONTROLAIR FOR COMBUSTION AND VENTILATION PROVIDING ADEQUATE VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION VENTILATION AIRAIR FOR COMBUSTION AND VENTILATION ContinuedINSTALLATION AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From OutdoorsINSTALLATION CLEARANCES INSTALLATION SEQUENCEREMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLY CHECK GAS TYPEELECTRICAL CONNECTIONS FOR POWER CORD RELOCATING WALL SWITCHINSTALLATION ContinuedINSTALLATION For Mantel InstallationContinued CAUTION Do not apply excessive pull on cordINSTALLATION INSTALLING VARIABLE SPEED BLOWER ACCESSORYContinued 8.Plug in blower power cord INSTALLATIONContinued INSTALLING THERMOSTATIC BLOWER ACCESSORY INSTALLATIONFireplace Screen and Floor Assembly, page Continued12.Plug in blower power cord INSTALLATIONContinued INSTALLING GAS PIPING TO FIREPLACE LOCATION INSTALLATIONINSTALLATION ContinuedInstallation Items Needed INSTALLATIONContinued CONNECTING FIREPLACE TO GAS SUPPLY CHECKING GAS CONNECTIONSINSTALLATION ContinuedCONVENTIONAL FIREPLACE INSTALLATION INSTALLATIONContinued necting Fireplace to Gas Supply, pageINSTALLATION BUILT-INFIREPLACE INSTALLATIONContinued Included with Mantel Accessory ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIMINSTALLATION ContinuedINSTALLING LOGS CGEFP33PR/CGEFP33NR INSTALLING HOODINSTALLATION ContinuedINSTALLATION INSTALLING LOGS EFP33PR/EFP33NRContinued INSTALLING BATTERY INTO REMOTE FOR YOUR SAFETY READ BEFORE LIGHTINGINSTALLING SCREEN OPERATING FIREPLACENORMAL LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEOPERATING FIREPLACE ContinuedELECTRICAL POWER OUTAGE MANUAL LIGHTING INSTRUCTIONS FOROPTIONAL BLOWER OPERATION OPERATING FIREPLACECLEANING AND MAINTENANCE CLEANING BURNER INJECTOR HOLDERINSPECTING BURNERS PILOT FLAME PATTERNSPECIFICATIONS SERVICE HINTSTECHNICAL SERVICE CLEANING PILOT AIR INLET HOLETROUBLESHOOTING Refer to Air for Combustion and VentiContinued TROUBLESHOOTINGHeater produces a whistling noise when TROUBLESHOOTING Continueding Gas Connections, pages 17 and ing Gas Connections, pages 17 andWIRING DIAGRAM REPLACEMENT PARTSPARTS UNDER WARRANTY PARTS NOT UNDER WARRANTYREMOTE CONTROL LOG BASE ASSEMBLY MODELSILLUSTRATED PARTS BREAKDOWNPARTS LIST PARTS LISTPART NUMBER EFP33ILLUSTRATED PARTS BREAKDOWN FIREBOX MODELS EFP33PR/NR AND CGEFP33PR/NR7ILLUSTRATED PARTS BREAKDOWN Models EFP33PR/NR and CGEFP33PR/NRFIREBOX MODELS EFP33PR/NR AND CGEFP33PR/NR PARTS LISTPARTS LIST PART NUMBERACCESSORIES BLOWER ACCESSORIESBRASS TRIM ACCESSORY Not Shown CLEANING KIT - CCK/GCKLAMINATE TRIM FOR HEARTH OR MANTEL HEARTH BASE for Use with Cabinet MantelCORNER HEARTH BASE SLIM HEARTH BASEPage TEMPLATES 3/8 Diameter 2 Holes 3/41/8 Diameter 2 Holes 3/4 4 3/4 3 3/4 3/8THIS PAGE INTENTIONALLY LEFT BLANK 108117-01HOWNERS REGISTRATION FORM TAPE Postage RequiredTAPE 2701 Industrial Drive P.O. Box Bowling Green, KYPage NOT A UPC 2701 Industrial Drive P.O. Box Bowling Green, KY