10
VENTING INSTALLATION INSTRUCTIONS
Installation Planning (Cont.)
VENTING INSTALLATION
INSTRUCTIONS
Continued
GROUND FLOOR INSTALLATION
Recommended Applications:
Minimum Pipe Overlap 11/4"
Siding Standoff
Screws
•Installation using cabinet surrounds
•Through the wall using round or square termination (up to 12" horizontal pipe)
•NOT FOR CORNER INSTALLATION
Direct Vent
Pipe
Wall
Firestop
Adjustable
Pipe 12" Max.
Horizontal High
Wind Square
Termination
45° Elbow
Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall
10" x 10" Framed Opening
High Wind Termination
Apply Mastic to Outside Edge of Standoff
Exterior Wall with Vinyl Siding
Wall Firestop
Square Termination
Vertical (V) | Horizontal (H) |
32" min. | 17" max. |
45° Elbow | Exterior Portion of Wall |
| |
Wall | Firestop (Round |
| Termination Only) |
Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed
Horizontal Termination Configurations
Figures 14 through 18 show different configurations and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: Remember that a horizontal run of venting must have a 1/4" rise for every 12" of run toward the termination.
WARNING: Never run vent downward as this may cause excessive temperatures which could cause a fire. Operation of improperly installed and main- tained venting system could result in serious injury, property damage or loss of life.
Firestop |
Slide Ring | Round | |
Termination | ||
Over Elbow to | ||
Cap | ||
Complete | ||
| ||
Connection |
|
(Kit HTK Shown)
Figure 14 - Horizontal Termination Configuration for Square and Round Terminations