Desa (V)T36EPA SERIES, (V)T36ENA SERIES Location Of Termination Cap, D E B L, V G V A

Page 6
LOCATION OF TERMINATION CAP

6

LOCATION OF TERMINATION CAP

LOCATION OF TERMINATION CAP

N

D N V

D

E Inside Corner V

B L Recessed Location

Balcony with No Side Wall C Balcony with Perpendicular Side Wall

Fixed

 

V

Closed

 

 

 

Openable

 

Figure 7 - Minimum Clearances for Termination Cap F Manual background V

Openable

B

Fixed

Closed

H

V

B

I

G

Manual background B Manual background

B

V J X

G

A

M

V

Manual background K Manual background X

V

G V A

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

RESTRICTED AREAManual background (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.5mc) minimum]

B= clearance to window or door that may be opened

[12 inches (30.5cm) minimum]

C = clearance to permanently closed window [minimum 12 inches (30.5cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (61cm) from the center-line of the terminal [18 inches (45.7cm) minimum]

E= clearance to unventilated soffit [12 inches (30.5cm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (91.4cm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (182.9cm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (30.5cm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (182.9cm) minimum]

L= clearance above paved side-walk or a paved driveway located on public property [*84 inches (213.3cm) minimum]

M= clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ]

N= clearance above a roof shall extend a minimum of 24 inches (61cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (45.7cm)

vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*

*as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A. Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

Outside Corner

A

 

 

 

A = 6" (15.2cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B Manual background B = 6" (15.2cm)

Recessed Location

Manual backgroundManual background D Manual backgroundManual background

C

C

Manual backgroundManual background E

V

Balcony with No Side Wall

G

V

G = 12" (30.5cm) minimum clearance

Balcony with Perpendicular Side Wall

H

V

Manual backgroundManual background J Manual background

Combustible &

Noncombustible

H = 24" (61cm)

J = 20" (50.8cm)

C = Maximum depth of 48" (121.9cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (61cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2cm) Noncombustible - 2" (5.1cm)

Figure 7 - Minimum Clearances for Termination Cap

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111251-01D

Image 6
Contents DIRECT-VENTFIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALTABLE OF CONTENTS SAFETY INFORMATIONContinued PRODUCT IDENTIFICATIONLOCAL CODES SAFETY INFORMATIONPRODUCT FEATURES PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS CLEARANCES PRE-INSTALLATION PREPARATIONContinued FRAMING AND FINISHINGV G V A LOCATION OF TERMINATION CAPD E B L LOCATION OF TERMINATION CAPINSTALLATION PLANNING VENTING INSTALLATION INSTRUCTIONSINSTALLATION PRECAUTIONS Horizontal Termination InstallationContinued VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS Female Locking Lugs Male SlotsVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSContinued VENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSHorizontal Termination Configurations ContinuedVENTING INSTALLATION INSTRUCTIONS ContinuedRecommended Applications Venting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 ElbowsFlat Ceiling Installation VENTING INSTALLATION INSTRUCTIONSINSTALLATION FOR VERTICAL TERMINATION ContinuedContinued VENTING INSTALLATION INSTRUCTIONSVertical Termination Configurations Venting with Two 90 ElbowsContinued VENTING INSTALLATION INSTRUCTIONSHIGH ALTITUDE INSTALLATION Vertical VentingDESA Venting Accessories FIREPLACE INSTALLATIONVENTING INSTALLATION INSTRUCTIONS Model BK InstallationFIREPLACE INSTALLATION Model BKT InstallationContinued FIREPLACE INSTALLATION Blower Wiring DiagramContinued FIREPLACE INSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONContinued Pressure Testing Gas Supply Piping System FIREPLACE INSTALLATIONInstallation Items Needed ContinuedCleaning Glass Door FIREPLACE INSTALLATIONPressure Testing Fireplace Gas Connections See Cleaning and Maintenance on pageFIREPLACE INSTALLATION INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERSContinued Figure 43 - Installing Log No FIREPLACE INSTALLATIONFIREPLACE INSTALLATION Figure 44 - Installing Logs No. 5 and NoWALL SWITCH INSTALLATION WIRING DIAGRAMFIREPLACE INSTALLATION OPTIONAL REMOTE CONTROL INSTALLATION Model WRCLIGHTING INSTRUCTIONS OPERATING FIREPLACEFOR YOUR SAFETY READ BEFORE LIGHTING TO TURN OFF GAS TO APPLIANCEOPERATING FIREPLACE INSPECTING BURNERSsee Troubleshooting, page ContinuedPILOT AND BURNERS CLEANING AND MAINTENANCEGLASS DOOR LOGSPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYContinued TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEILLUSTRATED PARTS BREAKDOWN MODELS VT36EN, VT36ENB VT36ENRA, VT36ENRBAVT36EPA22-5 VT36EPBA VT36EPRA VT36EPRBA visit www PARTS LISTFor more PARTS LISTModels VT36ENA, VT36ENBA, VT36ENRA BURNER ASSEMBLY MODELSILLUSTRATED PARTS BREAKDOWN VT36ENRBA, VT36EPA, VT36EPBA, VT36EPRA, VT36EPRBAPARTS LIST BURNER ASSEMBLY MODELSPARTS LIST TECHNICAL SERVICE REPLACEMENT PARTSSERVICE HINTS SPECIFICATIONSOWNERS REGISTRATION FORM For morevisit www TAPE Postage RequiredTAPE 111251-01DACCESSORIES WARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACE