Desa (V)T36EPA SERIES, (V)T36ENA SERIES Wiring Diagram, Fireplace Installation, Continued

Page 24
WALL SWITCH INSTALLATION

24

FIREPLACE INSTALLATION

Wall Switch Installation

 

Optional Remote Control Installation (Model WRC)

 

WIRING DIAGRAM

 

 

FIREPLACE INSTALLATION

Continued

WALL SWITCH INSTALLATION

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace. Refer to wiring diagram below.

OPTIONAL REMOTE CONTROL

INSTALLATION (Model WRC)

Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation.

1.Open lower louver panel of firebox.

2.The WRC model receiver does not require a battery. The re- ceiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 46).

3.Activate the remote handset battery by removing the insulat- ing tab on the back of the handset (see Figure 47). The battery is included pre-installed.

4.Once the battery is activated the unit is ready to use.

5.Close lower louver panel.

Fireplace

Receptacle

Remote Control

Receiver

Extension Cord

Ignition

Module Plug

Figure 46 - Installing the WRC Remote Receiver

OPTIONAL REMOTE CONTROLBattery Cover

12 Volt Battery

Back of

Pull to Remove

Handset

Insulation Tab

 

Figure 47 - Installing Battery into Back of Handset

WIRING DIAGRAM

Pilot Burner

INCOMING MAIN

 

GAS SUPPLY

Pilot Gas

 

 

Line

 

MV

 

TH

EV1

PV/MV

TR

 

 

GND

 

PV

 

IGN

EV2

24V AC

STEP DOWN

TRANSFORMER

120V AC

GAS LINE TO

BURNER

WALL SWITCH

(NOT SUPPLIED)

ON

OFF

BLACK

INCOMING

 

WHITE

120V AC

GREEN

(FUSE BOX

OR BREAKER)

BLACK

WHITE

GREEN

ELECTRICAL RATING:

120v, 60Hz, 0.7A

OPTIONAL

REMOTE

CONTROL

WIRING DIAGRAMManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111251-01D

Image 24
Contents DIRECT-VENTFIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALTABLE OF CONTENTS SAFETY INFORMATIONPRODUCT IDENTIFICATION LOCAL CODESContinued SAFETY INFORMATIONPRODUCT FEATURES PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS PRE-INSTALLATION PREPARATION ContinuedCLEARANCES FRAMING AND FINISHINGLOCATION OF TERMINATION CAP D E B LV G V A LOCATION OF TERMINATION CAPVENTING INSTALLATION INSTRUCTIONS INSTALLATION PRECAUTIONSINSTALLATION PLANNING Horizontal Termination InstallationVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSContinued Female Locking Lugs Male SlotsVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSContinued VENTING INSTALLATION INSTRUCTIONS Horizontal Termination ConfigurationsVENTING INSTALLATION INSTRUCTIONS ContinuedVENTING INSTALLATION INSTRUCTIONS ContinuedRecommended Applications VENTING INSTALLATION INSTRUCTIONS ContinuedVenting with Two 90 Elbows Venting with Two 90 ElbowsVENTING INSTALLATION INSTRUCTIONS INSTALLATION FOR VERTICAL TERMINATIONFlat Ceiling Installation ContinuedVENTING INSTALLATION INSTRUCTIONS Vertical Termination ConfigurationsContinued Venting with Two 90 ElbowsVENTING INSTALLATION INSTRUCTIONS HIGH ALTITUDE INSTALLATIONContinued Vertical VentingFIREPLACE INSTALLATION VENTING INSTALLATION INSTRUCTIONSDESA Venting Accessories Model BK InstallationFIREPLACE INSTALLATION Model BKT InstallationContinued FIREPLACE INSTALLATION Blower Wiring DiagramContinued FIREPLACE INSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONContinued FIREPLACE INSTALLATION Installation Items NeededPressure Testing Gas Supply Piping System ContinuedFIREPLACE INSTALLATION Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door See Cleaning and Maintenance on pageFIREPLACE INSTALLATION INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERSContinued FIREPLACE INSTALLATION FIREPLACE INSTALLATIONFigure 43 - Installing Log No Figure 44 - Installing Logs No. 5 and NoWIRING DIAGRAM FIREPLACE INSTALLATIONWALL SWITCH INSTALLATION OPTIONAL REMOTE CONTROL INSTALLATION Model WRCOPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEINSPECTING BURNERS see Troubleshooting, pageOPERATING FIREPLACE ContinuedCLEANING AND MAINTENANCE GLASS DOORPILOT AND BURNERS LOGSTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYTROUBLESHOOTING OBSERVED PROBLEMContinued POSSIBLE CAUSEILLUSTRATED PARTS BREAKDOWN MODELS VT36EN, VT36ENB VT36ENRA, VT36ENRBAVT36EPA22-5 VT36EPBA VT36EPRA VT36EPRBA PARTS LIST For morevisit www PARTS LISTBURNER ASSEMBLY MODELS ILLUSTRATED PARTS BREAKDOWNModels VT36ENA, VT36ENBA, VT36ENRA VT36ENRBA, VT36EPA, VT36EPBA, VT36EPRA, VT36EPRBAPARTS LIST BURNER ASSEMBLY MODELSPARTS LIST REPLACEMENT PARTS SERVICE HINTSTECHNICAL SERVICE SPECIFICATIONSOWNERS REGISTRATION FORM For morevisit www Postage Required TAPETAPE 111251-01DACCESSORIES WARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACE