The two most common causes of a malfunctioning gas appliance are:

1.Loose wiring connections

2.Construction debris clogging the pilot and/or gas control valve filter

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Ignitor will not spark or pilot will not light

1.

No gas supply, or shutoff valve is OFF

1.

Check to see if you have gas supply and

 

 

 

 

that equipment shutoff valve is opened

 

2.

Air in gas line

2.

Repeat lighting procedure several times

 

 

 

 

to purge all air out of lines. If after re-

 

 

 

 

peated attempts appliance does not light,

 

 

 

 

call for qualified service and repair.

 

3.

Construction debris clogging pilot orifice

3.

Remove debris and dirt, inspect and

 

 

 

 

clean any other possible obstructions

 

4.

Low gas pressure

4.

Contact your gas supplier to check

 

 

 

 

pressure

 

5.

Kinked pilot line

5.

Have a qualified technician replace pi-

 

 

 

 

lot line

 

6.

Control valve knob is not opening

6.

Replace control valve (Refer to Replace-

 

 

 

 

ment Parts, page 34)

 

7.

No power to unit or the ignition module

7.

Check that main power is on and that all

 

 

or power transformer is bad

 

wire connections are made correctly to

 

 

 

 

the ignition model (see Wiring Diagram,

 

 

 

 

page 24). Check for 24 VAC at the sec-

 

 

 

 

ondary side of the transformer. If 24

 

 

 

 

VAC is present, and the module does not

 

 

 

 

operate, have the module replaced oth-

 

 

 

 

erwise have the transformer replaced.

 

8.

Vent damper not fully open

8.

Open vent damper until fully locked in

 

 

 

 

OPEN position

 

 

 

 

 

Pilot will not stay lit

1.

Loose wiring on ignitor wire to ignition

 

 

module and/or poor ground to ignition

 

 

module

 

2.

Pilot flame too low to sense

1.Check wiring connection. Refer to wir- ing diagram (see Wiring Diagram, page

24)and/or check ground wire to igni- tion module

2.Clean and adjust pilot burner and check

gas supply and inlet pressure to unit

Note: Have a qualified technician replace pilot assembly if broken or corroded

No gas to burner, although wall switch and

1.

Wall switch wires defective or too long

1.

Check electrical connections

valve are set to the ON position

 

 

 

 

 

 

 

 

 

Frequent pilot outage

1.

Pilot flame may be too low, causing

1.

Clean and adjust pilot flame for maximum

 

 

safety pilot to “drop out”

 

flame impingement on thermopile

 

2.

Improper venting or excessive blockage

2.

Have the vent system inspected, includ-

 

 

 

 

ing the termination cap. Remove any

 

 

 

 

restriction or obstruction

For

 

.

 

.com

111251-01D

Image 28
Contents DIRECT-VENTFIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALTABLE OF CONTENTS SAFETY INFORMATIONPRODUCT IDENTIFICATION LOCAL CODESContinued SAFETY INFORMATIONPRE-INSTALLATION PREPARATION PRODUCT FEATURESLOCATION AND SPACE REQUIREMENTS PRE-INSTALLATION PREPARATION ContinuedCLEARANCES FRAMING AND FINISHINGLOCATION OF TERMINATION CAP D E B LV G V A LOCATION OF TERMINATION CAPVENTING INSTALLATION INSTRUCTIONS INSTALLATION PRECAUTIONSINSTALLATION PLANNING Horizontal Termination InstallationVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSContinued Female Locking Lugs Male SlotsVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSContinued VENTING INSTALLATION INSTRUCTIONS Horizontal Termination ConfigurationsVENTING INSTALLATION INSTRUCTIONS ContinuedContinued VENTING INSTALLATION INSTRUCTIONSRecommended Applications VENTING INSTALLATION INSTRUCTIONS ContinuedVenting with Two 90 Elbows Venting with Two 90 ElbowsVENTING INSTALLATION INSTRUCTIONS INSTALLATION FOR VERTICAL TERMINATIONFlat Ceiling Installation ContinuedVENTING INSTALLATION INSTRUCTIONS Vertical Termination ConfigurationsContinued Venting with Two 90 ElbowsVENTING INSTALLATION INSTRUCTIONS HIGH ALTITUDE INSTALLATIONContinued Vertical VentingFIREPLACE INSTALLATION VENTING INSTALLATION INSTRUCTIONSDESA Venting Accessories Model BK InstallationModel BKT Installation FIREPLACE INSTALLATIONContinued Blower Wiring Diagram FIREPLACE INSTALLATIONContinued INSTALLING GAS PIPING TO FIREPLACE LOCATION FIREPLACE INSTALLATIONContinued FIREPLACE INSTALLATION Installation Items NeededPressure Testing Gas Supply Piping System ContinuedFIREPLACE INSTALLATION Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door See Cleaning and Maintenance on pageINSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS FIREPLACE INSTALLATIONContinued FIREPLACE INSTALLATION FIREPLACE INSTALLATIONFigure 43 - Installing Log No Figure 44 - Installing Logs No. 5 and NoWIRING DIAGRAM FIREPLACE INSTALLATIONWALL SWITCH INSTALLATION OPTIONAL REMOTE CONTROL INSTALLATION Model WRCOPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEINSPECTING BURNERS see Troubleshooting, pageOPERATING FIREPLACE ContinuedCLEANING AND MAINTENANCE GLASS DOORPILOT AND BURNERS LOGSTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYTROUBLESHOOTING OBSERVED PROBLEMContinued POSSIBLE CAUSEMODELS VT36EN, VT36ENB VT36ENRA, VT36ENRBA ILLUSTRATED PARTS BREAKDOWNVT36EPA22-5 VT36EPBA VT36EPRA VT36EPRBA PARTS LIST For morevisit www PARTS LISTBURNER ASSEMBLY MODELS ILLUSTRATED PARTS BREAKDOWNModels VT36ENA, VT36ENBA, VT36ENRA VT36ENRBA, VT36EPA, VT36EPBA, VT36EPRA, VT36EPRBABURNER ASSEMBLY MODELS PARTS LISTPARTS LIST REPLACEMENT PARTS SERVICE HINTSTECHNICAL SERVICE SPECIFICATIONSFor more OWNERS REGISTRATION FORMvisit www Postage Required TAPETAPE 111251-01DACCESSORIES WARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACE