Desa (V)T36EPA SERIES, (V)T36ENA SERIES Inspecting Burners, Operating Fireplace, Continued

Page 26
INSPECTING BURNERS

26

OPERATING FIREPLACE

Operating Optional Blower Accessory

INSPECTING BURNERS

Pilot Assembly

Burner Flame Pattern

OPERATING FIREPLACE

Continued

OPERATING OPTIONAL

BLOWER ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

The BK manual blower and the BKT thermostatically-con- trolled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner.

The flame must envelope 1/4" of top of the ignitor/sensor and grounding stem.

If your pilot assembly does not meet these requirements:

Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 48, page 25). Do not move the adjustment screw.

see Troubleshooting, page 28

Pilot Burner

Sensing Rod

 

 

Ignitor/Sensor

Figure 50 - Correct Pilot Flame Pattern

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installa- tion to ensure proper installation and performance.

Figure 51 shows a typical flame pattern for.

If burner flame pattern differs from that described:

• turn fireplace off (see To Turn Off Gas to Appliance, page 25)

• see Troubleshooting, page 28

Figure 51 - Typical Flame Pattern

•see Troubleshooting, page 28Manual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111251-01D

Image 26
Contents DIRECT-VENTFIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALTABLE OF CONTENTS SAFETY INFORMATIONContinued PRODUCT IDENTIFICATIONLOCAL CODES SAFETY INFORMATIONLOCATION AND SPACE REQUIREMENTS PRODUCT FEATURESPRE-INSTALLATION PREPARATION CLEARANCES PRE-INSTALLATION PREPARATIONContinued FRAMING AND FINISHINGV G V A LOCATION OF TERMINATION CAPD E B L LOCATION OF TERMINATION CAPINSTALLATION PLANNING VENTING INSTALLATION INSTRUCTIONSINSTALLATION PRECAUTIONS Horizontal Termination InstallationContinued VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS Female Locking Lugs Male SlotsContinued VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSHorizontal Termination Configurations ContinuedRecommended Applications VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 ElbowsFlat Ceiling Installation VENTING INSTALLATION INSTRUCTIONSINSTALLATION FOR VERTICAL TERMINATION ContinuedContinued VENTING INSTALLATION INSTRUCTIONSVertical Termination Configurations Venting with Two 90 ElbowsContinued VENTING INSTALLATION INSTRUCTIONSHIGH ALTITUDE INSTALLATION Vertical VentingDESA Venting Accessories FIREPLACE INSTALLATIONVENTING INSTALLATION INSTRUCTIONS Model BK InstallationContinued FIREPLACE INSTALLATIONModel BKT Installation Continued FIREPLACE INSTALLATIONBlower Wiring Diagram Continued FIREPLACE INSTALLATIONINSTALLING GAS PIPING TO FIREPLACE LOCATION Pressure Testing Gas Supply Piping System FIREPLACE INSTALLATIONInstallation Items Needed ContinuedCleaning Glass Door FIREPLACE INSTALLATIONPressure Testing Fireplace Gas Connections See Cleaning and Maintenance on pageContinued FIREPLACE INSTALLATIONINSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS Figure 43 - Installing Log No FIREPLACE INSTALLATIONFIREPLACE INSTALLATION Figure 44 - Installing Logs No. 5 and NoWALL SWITCH INSTALLATION WIRING DIAGRAMFIREPLACE INSTALLATION OPTIONAL REMOTE CONTROL INSTALLATION Model WRCLIGHTING INSTRUCTIONS OPERATING FIREPLACEFOR YOUR SAFETY READ BEFORE LIGHTING TO TURN OFF GAS TO APPLIANCEOPERATING FIREPLACE INSPECTING BURNERSsee Troubleshooting, page ContinuedPILOT AND BURNERS CLEANING AND MAINTENANCEGLASS DOOR LOGSPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYContinued TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEVT36EPA22-5 VT36EPBA VT36EPRA VT36EPRBA ILLUSTRATED PARTS BREAKDOWNMODELS VT36EN, VT36ENB VT36ENRA, VT36ENRBA visit www PARTS LISTFor more PARTS LISTModels VT36ENA, VT36ENBA, VT36ENRA BURNER ASSEMBLY MODELSILLUSTRATED PARTS BREAKDOWN VT36ENRBA, VT36EPA, VT36EPBA, VT36EPRA, VT36EPRBAPARTS LIST PARTS LISTBURNER ASSEMBLY MODELS TECHNICAL SERVICE REPLACEMENT PARTSSERVICE HINTS SPECIFICATIONSvisit www OWNERS REGISTRATION FORMFor more TAPE Postage RequiredTAPE 111251-01DACCESSORIES WARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACE