TROUBLESHOOTING
TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
29
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY |
| ||
Fireplace produces a clicking/ticking noise | 1. | Metal expanding while heating or con- | 1. | This is common with most fireplaces. If | |
just after burner is lit or shut off |
| tracting while cooling |
| noise is excessive, contact qualified ser- | |
|
|
|
| vice person | |
|
|
|
|
|
|
Slight smoke or odor during initial operation | 1. | Residues from manufacturing processes | 1. | Problem will stop after a few hours of | |
|
| and logs curing |
| operation | |
|
|
|
|
|
|
Gas odor even when control knob is in OFF | 1. | Gas leak. See Warning statement at | 1. | Locate and correct all leaks (see Check- | |
position |
| top of page |
| ing Gas Connections, page 20) | |
| 2. | Control valve defective | 2. | Replace control valve | |
|
|
|
|
|
|
Gas odor during combustion | 1. | Foreign matter between control valve | 1. | Take apart gas tubing and remove for- | |
|
| and burner |
| eign matter | |
| 2. | Gas leak. See Warning statement at | 2. | Locate and correct all leaks (see Con- | |
|
| top of page |
| necting Fireplace to Gas Supply, | |
|
|
|
| page 20) | |
|
|
|
|
|
|
Glass soots | 1. | Flame impingement on logs | 1. | Adjust the log set so that the flame does | |
|
|
|
| not excessively impinge on it | |
| 2. | Debris around burner air mixer | 2. | Inspect the opening at the base of the | |
|
|
|
| burner to see that it is NOT packed with | |
|
|
|
| any type of material | |
|
|
|
|
|
|
Dark residue on logs or inside of fireplace | 1. | Improper log placement | 1. | Properly locate logs (see log placement | |
|
|
|
| sections on page 23) | |
| 2. | Air holes at burner inlet blocked | 2. | Clean out air holes at burner inlets. Pe- | |
|
|
|
| riodically repeat as needed | |
| 3. | Burner flame holes blocked | 3. | Remove blockage or replace burner | |
| 4. | Improper venting or excessive blockage | 4. | Have the vent system inspected, includ- | |
|
|
|
| ing the termination cap. Remove any | |
|
|
|
| restrictions or obstruction | |
| 5. | Excessive amounts of embers and pan | 5. | Clear excess embers until a minimum | |
|
| material |
| gap of 1/2" remains under the grate |