Desa BDV34PA, BDV34NA installation manual Horizontal Termination Configurations, Horizontal Venting

Page 10

®BDV34NA AND BDV34PA

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

VENTING INSTALLATION

Continued

Horizontal Termination

Configurations

Figures 16 through 20 show different con- figurations for venting with horizontal ter- mination. Each figure includes a chart with vertical minimum/maximum and horizon- tal maximum dimensions which must be met. Seal all connections with high tem- perature silicone sealant (outer pipe only) as specified in the second warning statement on page 7. All horizontal terminations re- quire 1/4" rise per 12" of horizontal run.

Horizontal Venting

 

UP

Vertical (V)

Horizontal (H)

44" min.

29" max.

(30° and 90° only, no vertical pipe)

55" min.

41" max.

(30° elbow, 1' vertical pipe, 90° elbow)

67" min.

60" max.

79" min.

84" max.

96" min.

20' max.

Note: This configuration for use with

corner installation.

BVK Vent Kit Shown

Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow

UP

BGFVK Vent Kit Shown (recommended for use with cabinet mantels)

Horizontal Venting

Vertical (V)

Horizontal (H)

37" min.

10" max.

Figure 16 - Horizontal Termination Configuration for Rigid Venting

Horizontal Venting

See information in Figure 17 for Vertical(V) and Horizontal(H) maxi- mums and mini- mums. The same amounts apply for flexible venting.

Note: Figure 16 applies to rigid venting only.

UP

BFGFVK and FGFVK Vent Kits Shown

Figure 18 - Horizontal Termination Using Flexible Venting

10

105980

Image 10
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyNatural GAS Model BDV34NA PROPANE/LP GAS Model BDV34PA Safety Information BDV34NA and BDV34PAGlossary Terms Product FeaturesProduct Identification Local CodesClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting Vanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Flexible VentingInstalling GA3700/DA3610T Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypeSide View Installing GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Installing Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver REMOVING/REPLACING Glass DoorInstalling Optional Brick Liner D8037A Installing Left Side Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoOperating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsInspecting Burners Operating Optional Blower AccessoryPilot Assembly Optional Remote OperationCleaning and Maintenance Troubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsSpecifications BDV34NA BDV34PAAccessories Manual Blower KIT GA3700 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesDuplex Outlet KIT Brass Louver KITIllustrated PARTS37 Breakdown BDV34NA7 BDV34PAParts List DIRECT-VENT Fireplace BDV34NA BDV34PAWarranty Information